Literature DB >> 2607965

The synthesis of soft pulses with a specified frequency response.

M Shinnar1, L Bolinger, J S Leigh.   

Abstract

We propose a new approach to synthesizing shaped pulses, by first synthesizing a hard pulse sequence and then converting it to a soft pulse. In previous papers, we developed a new approach to synthesizing hard pulse sequences by exactly inverting the Bloch equation, which yields the optimal frequency response. These results can now be applied to shaped pulses. Specifically, one can specify (1) the total duration of the pulse, (2) the frequency range it is desired to perturb, (3) the perturbation desired and, (4) the frequency range it is desired not to perturb. One can then synthesize a shaped pulse which has the desired effect with the least possible error. This enables us to obtain very sharp inversion and pi/2 pulses.

Entities:  

Mesh:

Year:  1989        PMID: 2607965     DOI: 10.1002/mrm.1910120111

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

Review 1.  Recent advances in magnetic resonance neurospectroscopy.

Authors:  Yael Rosen; Robert E Lenkinski
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

2.  Temperature dependence of 1H NMR chemical shifts and its influence on estimated metabolite concentrations.

Authors:  Felizitas C Wermter; Nico Mitschke; Christian Bock; Wolfgang Dreher
Journal:  MAGMA       Date:  2017-07-06       Impact factor: 2.310

3.  Longitudinal free-breathing MRI measurement of murine lung physiology in a progressive model of lung fibrosis.

Authors:  Jinbang Guo; William D Hardie; Zackary I Cleveland; Cynthia Davidson; Xuefeng Xu; Satish K Madala; Jason C Woods
Journal:  J Appl Physiol (1985)       Date:  2019-02-07

4.  Combined spin- and gradient-echo perfusion-weighted imaging.

Authors:  Heiko Schmiedeskamp; Matus Straka; Rexford D Newbould; Greg Zaharchuk; Jalal B Andre; Jean-Marc Olivot; Michael E Moseley; Gregory W Albers; Roland Bammer
Journal:  Magn Reson Med       Date:  2011-11-23       Impact factor: 4.668

5.  Murine pulmonary imaging at 7T: T2* and T1 with anisotropic UTE.

Authors:  Jinbang Guo; Xuefeng Cao; Zackary I Cleveland; Jason C Woods
Journal:  Magn Reson Med       Date:  2017-08-15       Impact factor: 4.668

6.  Compensation of slice profile mismatch in combined spin- and gradient-echo echo-planar imaging pulse sequences.

Authors:  Heiko Schmiedeskamp; Matus Straka; Roland Bammer
Journal:  Magn Reson Med       Date:  2011-08-19       Impact factor: 4.668

7.  Signal scaling improves the signal-to-noise ratio of measurements with segmented 2D-selective radiofrequency excitations.

Authors:  Jürgen Finsterbusch; Martin G Busch; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2013-02-25       Impact factor: 4.668

8.  Design of multidimensional Shinnar-Le Roux radiofrequency pulses.

Authors:  Chao Ma; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2014-02-27       Impact factor: 4.668

9.  1H, 13C and 15N NMR assignments and solution secondary structure of rat Apo-S100 beta.

Authors:  J C Amburgey; F Abildgaard; M R Starich; S Shah; D C Hilt; D J Weber
Journal:  J Biomol NMR       Date:  1995-09       Impact factor: 2.835

10.  Single-Voxel 1 H MR spectroscopy of cerebral nicotinamide adenine dinucleotide (NAD+ ) in humans at 7T using a 32-channel volume coil.

Authors:  Puneet Bagga; Hari Hariharan; Neil E Wilson; Joanne C Beer; Russell T Shinohara; Mark A Elliott; Joseph A Baur; Francesco M Marincola; Walter R Witschey; Mohammad Haris; John A Detre; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2019-09-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.