Literature DB >> 22114040

Combined spin- and gradient-echo perfusion-weighted imaging.

Heiko Schmiedeskamp1, Matus Straka, Rexford D Newbould, Greg Zaharchuk, Jalal B Andre, Jean-Marc Olivot, Michael E Moseley, Gregory W Albers, Roland Bammer.   

Abstract

In this study, a spin- and gradient-echo echo-planar imaging (SAGE EPI) MRI pulse sequence is presented that allows simultaneous measurements of gradient-echo and spin-echo dynamic susceptibility-contrast perfusion-weighted imaging data. Following signal excitation, five readout trains were acquired using spin- and gradient-echo echo-planar imaging, all of them with echo times of less than 100 ms. Contrast agent concentrations in brain tissue were determined based on absolute R2* and R(2) estimates rather than relative changes in the signals of individual echo trains, producing T(1)-independent dynamic susceptibility-contrast perfusion-weighted imaging data. Moreover, this acquisition technique enabled vessel size imaging through the simultaneous quantification of R2* and R(2), without an increase in acquisition time. In this work, the concepts of SAGE EPI pulse sequence and results in stroke and tumor imaging are presented. Overall, SAGE EPI combined the advantages of higher sensitivity to contrast agent passage of gradient-echo perfusion-weighted imaging with better microvascular selectivity of spin-echo perfusion-weighted imaging.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22114040      PMCID: PMC3374915          DOI: 10.1002/mrm.23195

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  44 in total

1.  Perfusion MRI of the human brain with dynamic susceptibility contrast: gradient-echo versus spin-echo techniques.

Authors:  O Speck; L Chang; N M DeSilva; T Ernst
Journal:  J Magn Reson Imaging       Date:  2000-09       Impact factor: 4.813

2.  Tailored utilization of acquired k-space points for GRAPPA reconstruction.

Authors:  Peng Qu; Gary X Shen; Chunsheng Wang; Bing Wu; Jing Yuan
Journal:  J Magn Reson       Date:  2005-05       Impact factor: 2.229

3.  Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation.

Authors:  B F Kjølby; L Østergaard; V G Kiselev
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

4.  Assessment of regional cerebral blood volume in acute human stroke by use of single-slice dynamic susceptibility contrast-enhanced magnetic resonance imaging.

Authors:  J Röther; F Gückel; W Neff; A Schwartz; M Hennerici
Journal:  Stroke       Date:  1996-06       Impact factor: 7.914

5.  Optimal location for arterial input function measurements near the middle cerebral artery in first-pass perfusion MRI.

Authors:  Egbert J W Bleeker; Mark A van Buchem; Matthias J P van Osch
Journal:  J Cereb Blood Flow Metab       Date:  2009-01-14       Impact factor: 6.200

Review 6.  Contrast agents and cerebral hemodynamics.

Authors:  B R Rosen; J W Belliveau; B R Buchbinder; R C McKinstry; L M Porkka; D N Kennedy; M S Neuder; C R Fisel; H J Aronen; K K Kwong
Journal:  Magn Reson Med       Date:  1991-06       Impact factor: 4.668

7.  High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis.

Authors:  L Ostergaard; R M Weisskoff; D A Chesler; C Gyldensted; B R Rosen
Journal:  Magn Reson Med       Date:  1996-11       Impact factor: 4.668

8.  Cerebral ischemia. II. The no-reflow phenomenon.

Authors:  A Ames; R L Wright; M Kowada; J M Thurston; G Majno
Journal:  Am J Pathol       Date:  1968-02       Impact factor: 4.307

9.  Utility of simultaneously acquired gradient-echo and spin-echo cerebral blood volume and morphology maps in brain tumor patients.

Authors:  K M Donahue; H G Krouwer; S D Rand; A P Pathak; C S Marszalkowski; S C Censky; R W Prost
Journal:  Magn Reson Med       Date:  2000-06       Impact factor: 4.668

10.  Acute stroke imaging research roadmap.

Authors:  Max Wintermark; Gregory W Albers; Andrei V Alexandrov; Jeffry R Alger; Roland Bammer; Jean-Claude Baron; Stephen Davis; Bart M Demaerschalk; Colin P Derdeyn; Geoffrey A Donnan; James D Eastwood; Jochen B Fiebach; Marc Fisher; Karen L Furie; Gregory V Goldmakher; Werner Hacke; Chelsea S Kidwell; Stephan P Kloska; Martin Köhrmann; Walter Koroshetz; Ting-Yim Lee; Kennedy R Lees; Michael H Lev; David S Liebeskind; Leif Ostergaard; William J Powers; James Provenzale; Peter Schellinger; Robert Silbergleit; Alma Gregory Sorensen; Joanna Wardlaw; Ona Wu; Steven Warach
Journal:  Stroke       Date:  2008-04-10       Impact factor: 7.914

View more
  40 in total

1.  ASFNR recommendations for clinical performance of MR dynamic susceptibility contrast perfusion imaging of the brain.

Authors:  K Welker; J Boxerman; A Kalnin; T Kaufmann; M Shiroishi; M Wintermark
Journal:  AJNR Am J Neuroradiol       Date:  2015-04-23       Impact factor: 3.825

2.  Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI).

Authors:  Robert J Harris; Jingwen Yao; Ararat Chakhoyan; Catalina Raymond; Kevin Leu; Linda M Liau; Phioanh L Nghiemphu; Albert Lai; Noriko Salamon; Whitney B Pope; Timothy F Cloughesy; Benjamin M Ellingson
Journal:  Magn Reson Med       Date:  2018-04-06       Impact factor: 4.668

3.  Highly accelerated multishot echo planar imaging through synergistic machine learning and joint reconstruction.

Authors:  Berkin Bilgic; Itthi Chatnuntawech; Mary Kate Manhard; Qiyuan Tian; Congyu Liao; Siddharth S Iyer; Stephen F Cauley; Susie Y Huang; Jonathan R Polimeni; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-05-20       Impact factor: 4.668

4.  Matching of postcontraction perfusion to oxygen consumption across submaximal contraction intensities in exercising humans.

Authors:  Amanda K W Buck; Christopher P Elder; Manus J Donahue; Bruce M Damon
Journal:  J Appl Physiol (1985)       Date:  2015-06-11

5.  Moving Toward a Consensus DSC-MRI Protocol: Validation of a Low-Flip Angle Single-Dose Option as a Reference Standard for Brain Tumors.

Authors:  K M Schmainda; M A Prah; L S Hu; C C Quarles; N Semmineh; S D Rand; J M Connelly; B Anderies; Y Zhou; Y Liu; B Logan; A Stokes; G Baird; J L Boxerman
Journal:  AJNR Am J Neuroradiol       Date:  2019-03-28       Impact factor: 3.825

Review 6.  Imaging brain oxygenation with MRI using blood oxygenation approaches: methods, validation, and clinical applications.

Authors:  T Christen; D S Bolar; G Zaharchuk
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-02       Impact factor: 3.825

7.  Simultaneous perfusion and permeability measurements using combined spin- and gradient-echo MRI.

Authors:  Heiko Schmiedeskamp; Jalal B Andre; Matus Straka; Thomas Christen; Seema Nagpal; Lawrence Recht; Reena P Thomas; Greg Zaharchuk; Roland Bammer
Journal:  J Cereb Blood Flow Metab       Date:  2013-03-06       Impact factor: 6.200

8.  Echo planar time-resolved imaging (EPTI).

Authors:  Fuyixue Wang; Zijing Dong; Timothy G Reese; Berkin Bilgic; Mary Katherine Manhard; Jingyuan Chen; Jonathan R Polimeni; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-02-03       Impact factor: 4.668

9.  MR vascular fingerprinting: A new approach to compute cerebral blood volume, mean vessel radius, and oxygenation maps in the human brain.

Authors:  T Christen; N A Pannetier; W W Ni; D Qiu; M E Moseley; N Schuff; G Zaharchuk
Journal:  Neuroimage       Date:  2013-12-07       Impact factor: 6.556

10.  Assessment of a simplified spin and gradient echo (sSAGE) approach for human brain tumor perfusion imaging.

Authors:  Ashley M Stokes; Jack T Skinner; Thomas Yankeelov; C Chad Quarles
Journal:  Magn Reson Imaging       Date:  2016-07-22       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.