Literature DB >> 26058064

Quantifying and Reducing Posture-Dependent Distortion in Ballistocardiogram Measurements.

Abdul Qadir Javaid, Andrew D Wiens, Nathaniel Forrest Fesmire, Mary Ann Weitnauer, Omer T Inan.   

Abstract

Ballistocardiography is a noninvasive measurement of the mechanical movement of the body caused by cardiac ejection of blood. Recent studies have demonstrated that ballistocardiogram (BCG) signals can be measured using a modified home weighing scale and used to track changes in myocardial contractility and cardiac output. With this approach, the BCG can potentially be used both for preventive screening and for chronic disease management applications. However, for achieving high signal quality, subjects are required to stand still on the scale in an upright position for the measurement; the effects of intentional (for user comfort) or unintentional (due to user error) modifications in the position or posture of the subject during the measurement have not been investigated in the existing literature. In this study, we quantified the effects of different standing and seated postures on the measured BCG signals, and on the most salient BCG-derived features compared to reference standard measurements (e.g., impedance cardiography). We determined that the standing upright posture led to the least distorted signals as hypothesized, and that the correlation between BCG-derived timing interval features (R-J interval) and the preejection period, PEP (measured using ICG), decreased significantly with impaired posture or sitting position. We further implemented two novel approaches to improve the PEP estimates from other standing and sitting postures, using system identification and improved J-wave detection methods. These approaches can improve the usability of standing BCG measurements in unsupervised settings (i.e., the home), by improving the robustness to nonideal posture, as well as enabling high-quality seated BCG measurements.

Entities:  

Mesh:

Year:  2015        PMID: 26058064      PMCID: PMC4560978          DOI: 10.1109/JBHI.2015.2441876

Source DB:  PubMed          Journal:  IEEE J Biomed Health Inform        ISSN: 2168-2194            Impact factor:   5.772


  26 in total

1.  Wireless biomedical signal monitoring device on wheelchair using noncontact electro-mechanical film sensor.

Authors:  Jong-Myoung Kim; Joo-Hyun Hong; Myeong-Chan Cho; Eun-Jong Cha; Tae-Soo Lee
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

2.  Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph.

Authors:  O T Inan; M Etemadi; A Paloma; L Giovangrandi; G T A Kovacs
Journal:  Physiol Meas       Date:  2009-02-06       Impact factor: 2.833

3.  Robust ballistocardiogram acquisition for home monitoring.

Authors:  O T Inan; M Etemadi; R M Wiard; L Giovangrandi; G T A Kovacs
Journal:  Physiol Meas       Date:  2009-01-16       Impact factor: 2.833

4.  Development and preliminary validation of heart rate and breathing rate detection using a passive, ballistocardiography-based sleep monitoring system.

Authors:  David C Mack; James T Patrie; Paul M Suratt; Robin A Felder; Majd A Alwan
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-01

5.  Nonconstrained sleep monitoring system and algorithms using air-mattress with balancing tube method.

Authors:  Jae Hyuk Shin; Young Joon Chee; Do-Un Jeong; Kwang Suk Park
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-10-20

6.  Static-charge-sensitive bed ballistocardiography in cardiovascular monitoring.

Authors:  A Lindqvist; K Pihlajamäki; J Jalonen; V Laaksonen; J Alihanka
Journal:  Clin Physiol       Date:  1996-01

7.  A method of detecting heartbeat locations in the ballistocardiographic signal from the fiber-optic vital signs sensor.

Authors:  Mariusz Krej; Lukasz Dziuda; Franciszek Wojciech Skibniewski
Journal:  IEEE J Biomed Health Inform       Date:  2015-01-23       Impact factor: 5.772

8.  Pressure-flow studies in man during the Valsalva maneuver with observations on the mechanical properties of the ascending aorta.

Authors:  J C Greenfield; R L Cox; R R Hernández; C Thomas; F W Schoonmaker
Journal:  Circulation       Date:  1967-04       Impact factor: 29.690

9.  Monitoring respiration and cardiac activity using fiber Bragg grating-based sensor.

Authors:  Lukasz Dziuda; Franciszek Wojciech Skibniewski; Mariusz Krej; Jaroslaw Lewandowski
Journal:  IEEE Trans Biomed Eng       Date:  2012-04-13       Impact factor: 4.538

Review 10.  Impedance cardiography. The impact of new technology.

Authors:  L A Critchley
Journal:  Anaesthesia       Date:  1998-07       Impact factor: 6.955

View more
  6 in total

1.  Robust Sensing of Distal Pulse Waveforms on a Modified Weighing Scale for Ubiquitous Pulse Transit Time Measurement.

Authors:  Andrew M Carek; Omer T Inan
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2017-05-23       Impact factor: 3.833

2.  Elucidating the Hemodynamic Origin of Ballistocardiographic Forces: Toward Improved Monitoring of Cardiovascular Health at Home.

Authors:  Abdul Qadir Javaid; Hazar Ashouri; Srini Tridandapani; Omer T Inan
Journal:  IEEE J Transl Eng Health Med       Date:  2016-03-24       Impact factor: 3.316

3.  Ballistocardiogram-Based Approach to Cuffless Blood Pressure Monitoring: Proof of Concept and Potential Challenges.

Authors:  Chang-Sei Kim; Andrew M Carek; Omer T Inan; Ramakrishna Mukkamala; Jin-Oh Hahn
Journal:  IEEE Trans Biomed Eng       Date:  2018-01-24       Impact factor: 4.538

4.  Unobtrusive Estimation of Cardiac Contractility and Stroke Volume Changes Using Ballistocardiogram Measurements on a High Bandwidth Force Plate.

Authors:  Hazar Ashouri; Lara Orlandic; Omer T Inan
Journal:  Sensors (Basel)       Date:  2016-05-28       Impact factor: 3.576

5.  Physiological Association between Limb Ballistocardiogram and Arterial Blood Pressure Waveforms: A Mathematical Model-Based Analysis.

Authors:  Peyman Yousefian; Sungtae Shin; Azin Sadat Mousavi; Chang-Sei Kim; Barry Finegan; M Sean McMurtry; Ramakrishna Mukkamala; Dae-Geun Jang; Uikun Kwon; Youn Ho Kim; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2019-03-26       Impact factor: 4.379

6.  Efficient reference-free adaptive artifact cancellers for impedance cardiography based remote health care monitoring systems.

Authors:  Madhavi Mallam; K Chandra Bhutan Rao
Journal:  Springerplus       Date:  2016-06-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.