Literature DB >> 27620621

Elucidating the Hemodynamic Origin of Ballistocardiographic Forces: Toward Improved Monitoring of Cardiovascular Health at Home.

Abdul Qadir Javaid1, Hazar Ashouri1, Srini Tridandapani2, Omer T Inan1.   

Abstract

The ballistocardiogram (BCG), a signal describing the reaction forces of the body to cardiac ejection of blood, has recently gained interest in the research community as a potential tool for monitoring the mechanical aspects of cardiovascular health for patients at home and during normal activities of daily living. An important limitation in the field of BCG research is that while the BCG signal measures the forces of the body, the information desired (and understood) by clinicians and caregivers, regarding mechanical health of the cardiovascular system, is typically expressed as blood pressure or flow. This paper aims to explore, using system identification tools, the mathematical relationship between the BCG signal and the better-understood impedance cardiography (ICG) and arterial blood pressure (ABP) waveforms, with a series of human subject studies designed to asynchronously modulate cardiac output and blood pressure and with different magnitudes. With this approach, we demonstrate for 19 healthy subjects that the BCG waveform more closely maps to the ICG (flow) waveform as compared with the finger-cuff-based ABP (pressure) waveform, and that the BCG can provide a more accurate estimate of stroke volume ([Formula: see text], [Formula: see text]) as compared with pulse pressure changes ([Formula: see text]). We also examined, as a feasibility study, for one subject, the ability to calibrate the BCG measurement tool with an ICG measurement on the first day, and then track changes in stroke volume on subsequent days. Accordingly, we conclude that the BCG is a signal more closely related to blood flow than pressures, and that a key health parameter for titrating care-stroke volume-can potentially be accurately measured with BCG signals at home using unobtrusive and inexpensive hardware, such as a modified weighing scale, as compared with the state-of-the-art ICG and ABP devices, which are expensive and obtrusive for use at home.

Entities:  

Keywords:  Ballistocardiogram; cardiovascular health; hemodynamics; home monitoring

Year:  2016        PMID: 27620621      PMCID: PMC4991685          DOI: 10.1109/JTEHM.2016.2544752

Source DB:  PubMed          Journal:  IEEE J Transl Eng Health Med        ISSN: 2168-2372            Impact factor:   3.316


  23 in total

1.  Infrasonic cardiac signals: complementary windows to cardiovascular dynamics.

Authors:  Kouhyar Tavakolian; Brandon Ngai; Andrew P Blaber; Bozena Kaminska
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

2.  Novel methods for estimating the ballistocardiogram signal using a simultaneously acquired electrocardiogram.

Authors:  Omer T Inan; Mozziyar Etemadi; Richard M Wiard; Gregory T A Kovacs; Laurent Giovangrandi
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

3.  Nonconstrained sleep monitoring system and algorithms using air-mattress with balancing tube method.

Authors:  Jae Hyuk Shin; Young Joon Chee; Do-Un Jeong; Kwang Suk Park
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-10-20

4.  Reconstruction of brachial artery pressure from noninvasive finger pressure measurements.

Authors:  W J Bos; J van Goudoever; G A van Montfrans; A H van den Meiracker; K H Wesseling
Journal:  Circulation       Date:  1996-10-15       Impact factor: 29.690

5.  Static-charge-sensitive bed ballistocardiography in cardiovascular monitoring.

Authors:  A Lindqvist; K Pihlajamäki; J Jalonen; V Laaksonen; J Alihanka
Journal:  Clin Physiol       Date:  1996-01

6.  The evolution of computational hemodynamics as a clinical tool in decision making, patient specific treatment and clinical management.

Authors:  Diego Gallo; Andreas Anayiotos; Umberto Morbiducci
Journal:  Ann Biomed Eng       Date:  2015-01       Impact factor: 3.934

Review 7.  Systolic blood pressure, pulse pressure and arterial stiffness as cardiovascular risk factors.

Authors:  M E Safar
Journal:  Curr Opin Nephrol Hypertens       Date:  2001-03       Impact factor: 2.894

8.  Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring.

Authors:  Chang-Sei Kim; Andrew M Carek; Ramakrishna Mukkamala; Omer T Inan; Jin-Oh Hahn
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-02       Impact factor: 4.538

9.  Monitoring respiration and cardiac activity using fiber Bragg grating-based sensor.

Authors:  Lukasz Dziuda; Franciszek Wojciech Skibniewski; Mariusz Krej; Jaroslaw Lewandowski
Journal:  IEEE Trans Biomed Eng       Date:  2012-04-13       Impact factor: 4.538

10.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

View more
  3 in total

1.  Cardiovascular Function and Ballistocardiogram: A Relationship Interpreted via Mathematical Modeling.

Authors:  Giovanna Guidoboni; Lorenzo Sala; Moein Enayati; Riccardo Sacco; Marcela Szopos; James M Keller; Mihail Popescu; Laurel Despins; Virginia H Huxley; Marjorie Skubic
Journal:  IEEE Trans Biomed Eng       Date:  2019-02-06       Impact factor: 4.538

2.  Collaborative Paradigm of Preventive, Personalized, and Precision Medicine With Point-of-Care Technologies.

Authors:  Atam P Dhawan
Journal:  IEEE J Transl Eng Health Med       Date:  2016-12-09       Impact factor: 3.316

3.  Sleep Stage Estimation from Bed Leg Ballistocardiogram Sensors.

Authors:  Yasue Mitsukura; Brian Sumali; Masaki Nagura; Koichi Fukunaga; Masato Yasui
Journal:  Sensors (Basel)       Date:  2020-10-05       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.