Literature DB >> 26056545

Noninvasive monitoring of intra-abdominal pressure by measuring abdominal wall tension.

Yuan-Zhuo Chen1, Shu-Ying Yan2, Yan-Qing Chen1, Yu-Gang Zhuang1, Zhao Wei1, Shu-Qin Zhou1, Hu Peng1.   

Abstract

BACKGROUND: Noninvasive monitoring of intra-abdominal pressure (IAP) by measuring abdominal wall tension (AWT) was effective and feasible in previous postmortem and animal studies. This study aimed to investigate the feasibility of the AWT method for noninvasively monitoring IAP in the intensive care unit (ICU).
METHODS: In this prospective study, we observed patients with detained urethral catheters in the ICU of Shanghai Tenth People's Hospital between April 2011 and March 2013. The correlation between AWT and urinary bladder pressure (UBP) was analyzed by linear regression analysis. The effects of respiratory and body position on AWT were evaluated using the paired samples t test, whereas the effects of gender and body mass index (BMI) on baseline AWT (IAP<12 mmHg) were assessed using one-way analysis of variance.
RESULTS: A total of 51 patients were studied. A significant linear correlation was observed between AWT and UBP (R=0.986, P<0.01); the regression equation was Y=-1.369+9.57X (P<0.01). There were significant differences among the different respiratory phases and body positions (P<0.01). However, gender and BMI had no significant effects on baseline AWT (P=0.457 and 0.313, respectively).
CONCLUSIONS: There was a significant linear correlation between AWT and UBP and respiratory phase, whereas body position had significant effects on AWT but gender and BMI did not. Therefore, AWT could serve as a simple, rapid, accurate, and important method to monitor IAP in critically ill patients.

Entities:  

Keywords:  Abdominal compartment syndrome; Abdominal wall tension; Intra-abdominal pressure; Noninvasive monitoring

Year:  2015        PMID: 26056545      PMCID: PMC4458474          DOI: 10.5847/wjem.j.1920-8642.2015.02.009

Source DB:  PubMed          Journal:  World J Emerg Med        ISSN: 1920-8642


  15 in total

1.  Non-invasive measurement of intra-abdominal pressure: a preliminary study.

Authors:  G H van Ramshorst; J F Lange; R H M Goossens; N L Agudelo; G J Kleinrensink; M Verwaal; S F J Flipsen; W C J Hop; L S G L Wauben; J Jeekel
Journal:  Physiol Meas       Date:  2008-07-18       Impact factor: 2.833

2.  [Importance of abdominal compartment syndrome in Germany: a questionnaire].

Authors:  J Otto; D Kaemmer; J Höer; M Jansen; V Schumpelick; M Strik; R Kuhlen; A Schachtrupp
Journal:  Anaesthesist       Date:  2009-06       Impact factor: 1.041

3.  Measurement of intra-abdominal pressure in intensive care units in the United Kingdom: a national postal questionnaire study.

Authors:  N Ravishankar; J Hunter
Journal:  Br J Anaesth       Date:  2005-03-11       Impact factor: 9.166

4.  Noninvasive assessment of intra-abdominal pressure by measurement of abdominal wall tension.

Authors:  Gabriëlle H van Ramshorst; Mahdi Salih; Wim C J Hop; Oscar J F van Waes; Gert-Jan Kleinrensink; Richard H M Goossens; Johan F Lange
Journal:  J Surg Res       Date:  2010-03-05       Impact factor: 2.192

5.  Abdominal compartment syndrome in patients with severe acute pancreatitis in early stage.

Authors:  Hong Chen; Fei Li; Jia-Bang Sun; Jian-Guo Jia
Journal:  World J Gastroenterol       Date:  2008-06-14       Impact factor: 5.742

6.  Intra-abdominal hypertension in acute pancreatitis.

Authors:  Jan J De Waele; Ari K Leppäniemi
Journal:  World J Surg       Date:  2009-06       Impact factor: 3.352

7.  Survey on the perception and management of the abdominal compartment syndrome among Belgian surgeons.

Authors:  I E De Laet; E A J Hoste; J J De Waele
Journal:  Acta Chir Belg       Date:  2007 Nov-Dec       Impact factor: 1.090

8.  Prevalence of intra-abdominal hypertension in critically ill patients: a multicentre epidemiological study.

Authors:  Manu L N G Malbrain; Davide Chiumello; Paolo Pelosi; Alexander Wilmer; Nicola Brienza; Vincenzo Malcangi; David Bihari; Richard Innes; Jonathan Cohen; Pierre Singer; Andre Japiassu; Elizabeth Kurtop; Bart L De Keulenaer; Ronny Daelemans; Monica Del Turco; P Cosimini; Marco Ranieri; Luc Jacquet; Pierre-François Laterre; Luciano Gattinoni
Journal:  Intensive Care Med       Date:  2004-02-03       Impact factor: 17.440

9.  Acute hyperlipidemic pancreatitis in a pregnant woman.

Authors:  Ying Hang; Yi Chen; Li-Xiong Lu; Chang-Qing Zhu
Journal:  World J Emerg Med       Date:  2013

10.  The impact of body position on intra-abdominal pressure measurement: a multicenter analysis.

Authors:  Michael L Cheatham; Jan J De Waele; Inneke De Laet; Bart De Keulenaer; Sandy Widder; Andrew W Kirkpatrick; Adrian B Cresswell; Manu Malbrain; Zsolt Bodnar; Jorge H Mejia-Mantilla; Richard Reis; Michael Parr; Robert Schulze; Sonia Puig
Journal:  Crit Care Med       Date:  2009-07       Impact factor: 7.598

View more
  4 in total

1.  Preliminary study of reliability of transcutaneous sensors in measuring intraabdominal pressure.

Authors:  Maša Kušar; Mihajlo Djokić; Srdjan Djordjević; Marija Hribernik; Simon Krašna; Blaž Trotovšek
Journal:  Sci Rep       Date:  2022-05-18       Impact factor: 4.996

Review 2.  A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside.

Authors:  Salar Tayebi; Adrian Gutierrez; Ikram Mohout; Evelien Smets; Robert Wise; Johan Stiens; Manu L N G Malbrain
Journal:  J Clin Monit Comput       Date:  2020-07-22       Impact factor: 2.502

3.  Ultrasonography in the diagnosis and monitoring of intra-abdominal hypertension and abdominal compartment syndrome: Ultrasonografia a nadciśnienie wewnątrzbrzuszne i zespół przedziału brzusznego.

Authors:  Andrzej Smereczyński; Katarzyna Kołaczyk; Elżbieta Bernatowicz
Journal:  J Ultrason       Date:  2020-09-28

4.  A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection.

Authors:  Hao Tang; Dong Liu; Yong Guo; Huayu Zhang; Yang Li; Xiaoyu Peng; Yaoli Wang; Dongpo Jiang; Lianyang Zhang; Zhengguo Wang
Journal:  Med Devices (Auckl)       Date:  2021-04-22
  4 in total