Literature DB >> 32700152

A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside.

Salar Tayebi1, Adrian Gutierrez1, Ikram Mohout1, Evelien Smets1, Robert Wise2,3, Johan Stiens1, Manu L N G Malbrain4,5.   

Abstract

This review presents an overview of previously reported non-invasive intra-abdominal pressure (IAP) measurement techniques. Each section covers the basic physical principles and methodology of the various measurement techniques, the experimental results, and the advantages and disadvantages of each method. The most promising non-invasive methods for IAP measurement are microwave reflectometry and ultrasound assessment, in combination with an applied external force.

Entities:  

Keywords:  Abdominal compartment syndrome; Intensive care unit; Intra-abdominal pressure; Microwave reflectometry; Non-invasive measurement; Ultrasound

Year:  2020        PMID: 32700152      PMCID: PMC7889558          DOI: 10.1007/s10877-020-00561-4

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  28 in total

1.  Respiratory inductive plethysmography to assess respiratory variability and complexity in humans.

Authors:  Marie-Noëlle Fiamma; Ziyad Samara; Pierre Baconnier; Thomas Similowski; Christian Straus
Journal:  Respir Physiol Neurobiol       Date:  2006-12-12       Impact factor: 1.931

2.  Non-invasive measurement of intra-abdominal pressure: a preliminary study.

Authors:  G H van Ramshorst; J F Lange; R H M Goossens; N L Agudelo; G J Kleinrensink; M Verwaal; S F J Flipsen; W C J Hop; L S G L Wauben; J Jeekel
Journal:  Physiol Meas       Date:  2008-07-18       Impact factor: 2.833

3.  Evaluation of respiratory inductive plethysmography: accuracy for analysis of respiratory waveforms.

Authors:  P Y Carry; P Baconnier; A Eberhard; P Cotte; G Benchetrit
Journal:  Chest       Date:  1997-04       Impact factor: 9.410

Review 4.  The role of abdominal compliance, the neglected parameter in critically ill patients - a consensus review of 16. Part 2: measurement techniques and management recommendations.

Authors:  Manu L N G Malbrain; Inneke De Laet; Jan J De Waele; Michael Sugrue; Alexander Schachtrupp; Juan Duchesne; Gabrielle Van Ramshorst; Bart De Keulenaer; Andrew W Kirkpatrick; Siavash Ahmadi-Noorbakhsh; Jan Mulier; Paolo Pelosi; Rao Ivatury; Francisco Pracca; Marcelo David; Derek J Roberts
Journal:  Anaesthesiol Intensive Ther       Date:  2014 Nov-Dec

Review 5.  A systematic review and individual patient data meta-analysis on intra-abdominal hypertension in critically ill patients: the wake-up project. World initiative on Abdominal Hypertension Epidemiology, a Unifying Project (WAKE-Up!).

Authors:  M L N G Malbrain; D Chiumello; B M Cesana; A Reintam Blaser; J Starkopf; M Sugrue; P Pelosi; P Severgnini; G Hernandez; N Brienza; A W Kirkpatrick; A Schachtrupp; J Kempchen; E Estenssoro; M G Vidal; I De Laet; B L De Keulenaer
Journal:  Minerva Anestesiol       Date:  2013-12-12       Impact factor: 3.051

6.  Compression sonography for non-invasive measurement of lower leg compartment pressure in an animal model.

Authors:  Andreas Bloch; Corina Tomaschett; Stephan M Jakob; Andreas Schwinghammer; Timo Schmid
Journal:  Injury       Date:  2017-11-27       Impact factor: 2.586

7.  Towards estimation of respiratory muscle effort with respiratory inductance plethysmography signals and complementary ensemble empirical mode decomposition.

Authors:  Ya-Chen Chen; Tzu-Chien Hsiao
Journal:  Med Biol Eng Comput       Date:  2017-12-26       Impact factor: 2.602

8.  Noninvasive assessment of intra-abdominal pressure by measurement of abdominal wall tension.

Authors:  Gabriëlle H van Ramshorst; Mahdi Salih; Wim C J Hop; Oscar J F van Waes; Gert-Jan Kleinrensink; Richard H M Goossens; Johan F Lange
Journal:  J Surg Res       Date:  2010-03-05       Impact factor: 2.192

9.  In vivo measurement of the effect of intra-abdominal pressure on the human spine.

Authors:  P W Hodges; A G Cresswell; K Daggfeldt; A Thorstensson
Journal:  J Biomech       Date:  2001-03       Impact factor: 2.712

10.  Rational intraabdominal pressure monitoring: how to do it?

Authors:  J J De Waele; I De laet; M L N G Malbrain
Journal:  Acta Clin Belg       Date:  2007       Impact factor: 1.264

View more
  3 in total

1.  A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection.

Authors:  Hao Tang; Dong Liu; Yong Guo; Huayu Zhang; Yang Li; Xiaoyu Peng; Yaoli Wang; Dongpo Jiang; Lianyang Zhang; Zhengguo Wang
Journal:  Med Devices (Auckl)       Date:  2021-04-22

2.  Pre-Clinical Validation of A Novel Continuous Intra-Abdominal Pressure Measurement Equipment (SERENNO).

Authors:  Salar Tayebi; Robert Wise; Ali Pourkazemi; Johan Stiens; Manu L N G Malbrain
Journal:  Life (Basel)       Date:  2022-07-30

3.  Continuous intra-abdominal pressure: is it ready for prime time?

Authors:  Manu L N G Malbrain; Bart L De Keulenaer; Ashish K Khanna
Journal:  Intensive Care Med       Date:  2022-08-04       Impact factor: 41.787

  3 in total