Non-invasive measurement of intra-abdominal pressure: a preliminary study.

G H van Ramshorst1, J F Lange, R H M Goossens, N L Agudelo, G J Kleinrensink, M Verwaal, S F J Flipsen, W C J Hop, L S G L Wauben, J Jeekel.   

Abstract

The importance of measuring intra-abdominal pressure (IAP) has increased since the negative effects of sustained increased IAP, also known as intra-abdominal hypertension (IAH), have become known. The relation between IAP and abdominal wall tension has been included in several reports. We have developed a device to measure abdominal wall tension by measuring force and distance. This device enables us to investigate the correlation between the abdominal wall tension and IAP. The abdomens of two corpses (one female, one male) were insufflated with air. IAP was increased and measured at intervals by means of a laparoscopic set-up. Abdominal tension was measured at seven points on the abdominal wall at each interval. Pearson's correlation coefficients were used to determine the relationship between IAP and tension for each point measured. ANOVA was used to assess relations between measured tensions versus applied pressure, locations and subjects. In both corpses, all points showed significant (p < 0.001) correlations between IAP and abdominal wall tension. The points along the mid transverse plane appear to be more similar compared to more cranial and caudal points. We have assessed the feasibility of a device that non-invasively can track changes in IAP. Measurements performed with the device are preliminary results, and further investigation is needed.

Entities:  

Mesh:

Year:  2008        PMID: 18641425     DOI: 10.1088/0967-3334/29/8/N01

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  6 in total

1.  Noninvasive monitoring of intra-abdominal pressure by measuring abdominal wall tension.

Authors:  Yuan-Zhuo Chen; Shu-Ying Yan; Yan-Qing Chen; Yu-Gang Zhuang; Zhao Wei; Shu-Qin Zhou; Hu Peng
Journal:  World J Emerg Med       Date:  2015

2.  Preliminary study of reliability of transcutaneous sensors in measuring intraabdominal pressure.

Authors:  Maša Kušar; Mihajlo Djokić; Srdjan Djordjević; Marija Hribernik; Simon Krašna; Blaž Trotovšek
Journal:  Sci Rep       Date:  2022-05-18       Impact factor: 4.996

3.  Effect of retension sutures on abdominal pressure after abdominal surgery.

Authors:  Hao Tang; Dong Liu; Hai-Feng Qi; Ze-Ping Liang; Xiu-Zhu Zhang; Dong-Po Jiang; Lian-Yang Zhang
Journal:  Chin J Traumatol       Date:  2018-01-31

Review 4.  A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside.

Authors:  Salar Tayebi; Adrian Gutierrez; Ikram Mohout; Evelien Smets; Robert Wise; Johan Stiens; Manu L N G Malbrain
Journal:  J Clin Monit Comput       Date:  2020-07-22       Impact factor: 2.502

5.  A New Device for Measuring Abdominal Wall Tension and Its Value in Screening Abdominal Infection.

Authors:  Hao Tang; Dong Liu; Yong Guo; Huayu Zhang; Yang Li; Xiaoyu Peng; Yaoli Wang; Dongpo Jiang; Lianyang Zhang; Zhengguo Wang
Journal:  Med Devices (Auckl)       Date:  2021-04-22

6.  Stretchable Capacitive Pressure Sensing Sleeve Deployable onto Catheter Balloons towards Continuous Intra-Abdominal Pressure Monitoring.

Authors:  Kirthika Senthil Kumar; Zongyuan Xu; Manivannan Sivaperuman Kalairaj; Godwin Ponraj; Hui Huang; Chi-Fai Ng; Qing Hui Wu; Hongliang Ren
Journal:  Biosensors (Basel)       Date:  2021-05-14