Literature DB >> 26055082

Effect of Continuous Glucose Monitoring Accuracy on Clinicians' Retrospective Decision Making in Diabetes: A Pilot Study.

Zeinab Mahmoudi1, Mette Dencker Johansen1, Hanne Holdflod Nørgaard2, Steen Andersen2, Ulrik Pedersen-Bjergaard2, Lise Tarnow3, Jens Sandahl Christiansen4, Ole Hejlesen5.   

Abstract

BACKGROUND: The use of continuous glucose monitoring (CGM) in clinical decision making in diabetes could be limited by the inaccuracy of CGM data when compared to plasma glucose measurements. The aim of the present study is to investigate the impact of CGM numerical accuracy on the precision of diabetes treatment adjustments.
METHOD: CGM profiles with maximum 5-day duration from 12 patients with type 1 diabetes treated with a basal-bolus insulin regimen were processed by 2 CGM algorithms, with the accuracy of algorithm 2 being higher than the accuracy of algorithm 1, using the median absolute relative difference (MARD) as the measure of accuracy. During 2 separate and similar occasions over a 1-month interval, 3 clinicians reviewed the processed CGM profiles, and adjusted the dose level of basal and prandial insulin. The precision of the dosage adjustments were defined in terms of the interclinician agreement and the intraclinician reproducibility of the decisions. The Cohen's kappa coefficient was used to assess the precision of the decisions. The study was based on retrospective and blind CGM data.
RESULTS: For the interclinician agreement, in the first occasion, the kappa of algorithm 1 was .32, and that of algorithm 2 was .36. For the interclinician agreement, in the second occasion, the kappas of algorithms 1 and 2 were .17 and .22, respectively. For the intraclinician reproducibility of the decisions, the kappas of algorithm 1 were .35, .22, and .80 and the kappas of algorithm 2 were .44, .52, and .32, for the 3 clinicians, respectively. For the interclinician agreement, the relative kappa change from algorithm 1 to algorithm 2 was 86.06%, and for the intraclinician reproducibility, the relative kappa change from algorithm 1 to algorithm 2 was 53.99%.
CONCLUSIONS: Results indicated that the accuracy of CGM algorithms might potentially affect the precision of the CGM-based insulin adjustments for type 1 diabetes patients. However, a larger study with several clinical centers, with higher number of clinicians and patients is required to validate the impact of CGM accuracy on decisions precision.
© 2015 Diabetes Technology Society.

Entities:  

Keywords:  accuracy; continuous glucose monitoring algorithm; decision making; diabetes treatment adjustment; insulin adjustment; short-term continuous glucose monitoring; type 1 diabetes

Mesh:

Substances:

Year:  2015        PMID: 26055082      PMCID: PMC4667341          DOI: 10.1177/1932296815587935

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  51 in total

1.  Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study.

Authors:  B W Bode; T M Gross; K R Thornton; J J Mastrototaro
Journal:  Diabetes Res Clin Pract       Date:  1999-12       Impact factor: 5.602

2.  Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method.

Authors:  C Choleau; J C Klein; G Reach; B Aussedat; V Demaria-Pesce; G S Wilson; R Gifford; W K Ward
Journal:  Biosens Bioelectron       Date:  2002-08       Impact factor: 10.618

3.  Understanding interobserver agreement: the kappa statistic.

Authors:  Anthony J Viera; Joanne M Garrett
Journal:  Fam Med       Date:  2005-05       Impact factor: 1.756

4.  Accuracy of a new real-time continuous glucose monitoring algorithm.

Authors:  D Barry Keenan; Raymond Cartaya; John J Mastrototaro
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

5.  Interobserver reliability and intraobserver reproducibility of the modified Ficat classification system of osteonecrosis of the femoral head.

Authors:  S W Smith; R A Meyer; P M Connor; S E Smith; E N Hanley
Journal:  J Bone Joint Surg Am       Date:  1996-11       Impact factor: 5.284

6.  Professional continuous glucose monitoring in subjects with type 1 diabetes: retrospective hypoglycemia detection.

Authors:  Morten Hasselstrøm Jensen; Toke Folke Christensen; Lise Tarnow; Zeinab Mahmoudi; Mette Dencker Johansen; Ole Kristian Hejlesen
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

7.  Perceived accuracy in continuous glucose monitoring: understanding the impact on patients.

Authors:  William H Polonsky; Danielle Hessler
Journal:  J Diabetes Sci Technol       Date:  2014-11-10

8.  Assessment of the AO/ASIF fracture classification for the distal tibia.

Authors:  J S Martin; J L Marsh; S K Bonar; T A DeCoster; E M Found; E A Brandser
Journal:  J Orthop Trauma       Date:  1997-10       Impact factor: 2.512

9.  The role of continuous glucose monitoring in clinical decision-making in diabetes in pregnancy.

Authors:  Kylie McLachlan; Alicia Jenkins; David O'Neal
Journal:  Aust N Z J Obstet Gynaecol       Date:  2007-06       Impact factor: 2.100

10.  Continuous glucose monitoring for treatment adjustment in diabetic pregnancies--a pilot study.

Authors:  Y Yogev; A Ben-Haroush; R Chen; B Kaplan; M Phillip; M Hod
Journal:  Diabet Med       Date:  2003-07       Impact factor: 4.359

View more
  1 in total

1.  Designing Decision-Support Technologies for Patient-Generated Data in Type 1 Diabetes.

Authors:  Si Sun; Kaitlin L Costello
Journal:  AMIA Annu Symp Proc       Date:  2018-04-16
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.