Literature DB >> 26784127

Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities.

David Rodbard1.   

Abstract

Continuous glucose monitoring (CGM) provides information unattainable by intermittent capillary blood glucose, including instantaneous real-time display of glucose level and rate of change of glucose, alerts and alarms for actual or impending hypo- and hyperglycemia, "24/7" coverage, and the ability to characterize glycemic variability. Progressively more accurate and precise, reasonably unobtrusive, small, comfortable, user-friendly devices connect to the Internet to share information and are sine qua non for a closed-loop artificial pancreas. CGM can inform, educate, motivate, and alert people with diabetes. CGM is medically indicated for patients with frequent, severe, or nocturnal hypoglycemia, especially in the presence of hypoglycemia unawareness. Surprisingly, despite tremendous advances, utilization of CGM has remained fairly limited to date. Barriers to use have included the following: (1) lack of Food and Drug Administration approval, to date, for insulin dosing ("nonadjuvant use") in the United States and for use in hospital and intensive care unit settings; (2) cost and variable reimbursement; (3) need for recalibrations; (4) periodic replacement of sensors; (5) day-to-day variability in glycemic patterns, which can limit the predictability of findings based on retrospective, masked "professional" use; (6) time, implicit costs, and inconvenience for uploading of data for retrospective analysis; (7) lack of fair and reasonable reimbursement for physician time; (8) inexperience and lack of training of physicians and other healthcare professionals regarding interpretation of CGM results; (9) lack of standardization of software methods for analysis of CGM data; and (10) need for professional medical organizations to develop and disseminate additional clinical practice guidelines regarding the role of CGM. Ongoing advances in technology and clinical research have addressed several of these barriers. Use of CGM in conjunction with an insulin pump with automated suspension of insulin infusion in response to actual observed or predicted hypoglycemia, as well as progressive refinement of closed-loop systems, is expected to dramatically enhance the clinical utility and utilization of CGM.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26784127      PMCID: PMC4717493          DOI: 10.1089/dia.2015.0417

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  50 in total

1.  Accuracy of the Sof-sensor glucose sensor with the iPro calibration algorithm.

Authors:  John B Welsh; Francine R Kaufman; Scott W Lee
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

2.  Hypoglycemia Reduction and Accuracy of Continuous Glucose Monitoring.

Authors:  Boris P Kovatchev
Journal:  Diabetes Technol Ther       Date:  2015-05-15       Impact factor: 6.118

3.  Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D Exchange clinic registry.

Authors:  Kellee M Miller; Nicole C Foster; Roy W Beck; Richard M Bergenstal; Stephanie N DuBose; Linda A DiMeglio; David M Maahs; William V Tamborlane
Journal:  Diabetes Care       Date:  2015-06       Impact factor: 19.112

4.  A clinical trial of the accuracy and treatment experience of the Dexcom G4 sensor (Dexcom G4 system) and Enlite sensor (guardian REAL-time system) tested simultaneously in ambulatory patients with type 1 diabetes.

Authors:  Viktorija Matuleviciene; Jeffrey I Joseph; Mervi Andelin; Irl B Hirsch; Stig Attvall; Aldina Pivodic; Sofia Dahlqvist; David Klonoff; Börje Haraldsson; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2014-09-18       Impact factor: 6.118

5.  Clinical interpretation of indices of quality of glycemic control and glycemic variability.

Authors:  David Rodbard
Journal:  Postgrad Med       Date:  2011-07       Impact factor: 3.840

Review 6.  The benefits, limitations, and cost-effectiveness of advanced technologies in the management of patients with diabetes mellitus.

Authors:  Robert A Vigersky
Journal:  J Diabetes Sci Technol       Date:  2015-03

7.  Multinight "bedside" closed-loop control for patients with type 1 diabetes.

Authors:  Sue A Brown; Boris P Kovatchev; Marc D Breton; Stacey M Anderson; Patrick Keith-Hynes; Stephen D Patek; Boyi Jiang; Najib Ben Brahim; Paul Vereshchetin; Daniela Bruttomesso; Angelo Avogaro; Simone Del Favero; Federico Boscari; Silvia Galasso; Roberto Visentin; Marco Monaro; Claudio Cobelli
Journal:  Diabetes Technol Ther       Date:  2015-01-16       Impact factor: 6.118

8.  Characterizing glucose exposure for individuals with normal glucose tolerance using continuous glucose monitoring and ambulatory glucose profile analysis.

Authors:  Roger S Mazze; Ellie Strock; David Wesley; Sarah Borgman; Blaine Morgan; Richard Bergenstal; Robert Cuddihy
Journal:  Diabetes Technol Ther       Date:  2008-06       Impact factor: 6.118

9.  Progress in Diabetes Technology: Developments in Insulin Pumps, Continuous Glucose Monitors, and Progress towards the Artificial Pancreas.

Authors:  Gregory P Forlenza; Bruce Buckingham; David M Maahs
Journal:  J Pediatr       Date:  2015-11-05       Impact factor: 4.406

10.  Predictive Low-Glucose Insulin Suspension Reduces Duration of Nocturnal Hypoglycemia in Children Without Increasing Ketosis.

Authors:  Bruce A Buckingham; Dan Raghinaru; Fraser Cameron; B Wayne Bequette; H Peter Chase; David M Maahs; Robert Slover; R Paul Wadwa; Darrell M Wilson; Trang Ly; Tandy Aye; Irene Hramiak; Cheril Clarson; Robert Stein; Patricia H Gallego; John Lum; Judy Sibayan; Craig Kollman; Roy W Beck
Journal:  Diabetes Care       Date:  2015-06-06       Impact factor: 19.112

View more
  142 in total

1.  A Review of Continuous Glucose Monitoring Data Interpretation in the Age of Automated Insulin Delivery.

Authors:  Laya Ekhlaspour; Ideen Tabatabai; Bruce Buckingham
Journal:  J Diabetes Sci Technol       Date:  2019-05-26

Review 2.  Wearable biosensors for healthcare monitoring.

Authors:  Jayoung Kim; Alan S Campbell; Berta Esteban-Fernández de Ávila; Joseph Wang
Journal:  Nat Biotechnol       Date:  2019-02-25       Impact factor: 54.908

Review 3.  Glucose-Responsive Insulin and Delivery Systems: Innovation and Translation.

Authors:  Jinqiang Wang; Zejun Wang; Jicheng Yu; Anna R Kahkoska; John B Buse; Zhen Gu
Journal:  Adv Mater       Date:  2019-08-18       Impact factor: 30.849

Review 4.  Use of Diabetes Technology in Children: Role of Structured Education for Young People with Diabetes and Families.

Authors:  Hannah R Desrochers; Alan T Schultz; Lori M Laffel
Journal:  Endocrinol Metab Clin North Am       Date:  2020-03       Impact factor: 4.741

5.  Health Care Provider Knowledge and Perceptions of FDA-Approved and Do-It-Yourself Automated Insulin Delivery.

Authors:  James A Murray; Margaret F Clayton; Michelle L Litchman
Journal:  J Diabetes Sci Technol       Date:  2019-12-26

6.  Tissue Response to Subcutaneous Infusion Catheter.

Authors:  Ershuai Zhang; Zhiqiang Cao
Journal:  J Diabetes Sci Technol       Date:  2019-03-31

Review 7.  Wireless and battery-free platforms for collection of biosignals.

Authors:  Tucker Stuart; Le Cai; Alex Burton; Philipp Gutruf
Journal:  Biosens Bioelectron       Date:  2021-01-23       Impact factor: 10.618

Review 8.  Closing the Loop.

Authors:  Revital Nimri; Nathan Murray; Alexander Ochs; Jordan E Pinsker; Eyal Dassau
Journal:  Diabetes Technol Ther       Date:  2017-02       Impact factor: 6.118

Review 9.  Continuous Glucose Monitoring and Global Reimbursement: An Update.

Authors:  Claudia Graham
Journal:  Diabetes Technol Ther       Date:  2017-06       Impact factor: 6.118

10.  Diabetes and Prediabetes Classification Using Glycemic Variability Indices From Continuous Glucose Monitoring Data.

Authors:  Giada Acciaroli; Giovanni Sparacino; Liisa Hakaste; Andrea Facchinetti; Giorgio Maria Di Nunzio; Alessandro Palombit; Tiinamaija Tuomi; Rafael Gabriel; Jaime Aranda; Saturio Vega; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2017-06-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.