Literature DB >> 26040794

[Influence of corneal pachymetric changes on functional results after cataract surgery].

F N Auerbach1, M P Holzer1, G U Auffarth1, R Khoramnia1, B C Thomas1, D Saure2, T M Rabsilber3.   

Abstract

BACKGROUND: In the early postoperative period following uncomplicated cataract surgery, the correlation of corrected distance visual acuity (CDVA) and the increase in corneal thickness and anterior chamber depth (ACD) are investigated. PATIENTS AND METHODS: A total of 54 cataract patients with a mean age of 70 ± 8.4 years were included in this prospective study. Surgery was carried out on one eye of each patient according to the study protocol. Refraction, CDVA and ACD were evaluated 1 day and 1 week postoperatively and compared with the pachymetry results measured with the Pentacam.
RESULTS: The mean postoperative CDVA significantly improved from 0.31 ± 0.24 logMAR to 0.18 ± 0.22 logMAR after one day and up to 0.06 ± 0.13 logMAR one week after surgery (p < 0.05). The mean spherical equivalent was - 0.52 ± 0.69 D after one day and - 0.50 ± 0.82 D one week after surgery and showed only minimal differences compared to the mean target refraction of - 0.39 ± 0.70 D. Postoperative corneal thickness showed a significant increase compared to the preoperative results (p < 0.05) on both visits: the mean difference was 33.26 ± 50.20 µm (- 17 to 315 µm) on the first day and 20.22 ± 23.15 µm (- 10 to 99 µm) one week after surgery. Up to 7 days postoperatively the increase in corneal thickness and CDVA showed only moderate or no correlations (r = 0.465 vs. r = 0.072, respectively). Regarding pachymetry and ACD values, no or only low correlations were found.
CONCLUSION: The significant increase in corneal thickness on the first and seventh day shows no to moderate correlation to the CDVA. Nevertheless, a good and early rehabilitation of visual acuity following uncomplicated cataract surgery is possible. Intraocular pressure measurement can lead to false high results due to an increase in corneal thickness.

Entities:  

Keywords:  Anterior chamber depth; Cataract surgery; Corneal thickness; Pentacam; Visual acuity

Mesh:

Year:  2015        PMID: 26040794     DOI: 10.1007/s00347-015-0009-7

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  25 in total

1.  Endothelial cell loss after phacoemulsification: relation to preoperative and intraoperative parameters.

Authors:  T Walkow; N Anders; S Klebe
Journal:  J Cataract Refract Surg       Date:  2000-05       Impact factor: 3.351

2.  Free radicals in phacoemulsification and aspiration procedures.

Authors:  Hiroshi Takahashi; Atsuhiro Sakamoto; Ryoki Takahashi; Takeo Ohmura; Shigeto Shimmura; Kunitoshi Ohara
Journal:  Arch Ophthalmol       Date:  2002-10

3.  Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound.

Authors:  Birgit Lackner; Gerald Schmidinger; Stefan Pieh; Martin A Funovics; Christian Skorpik
Journal:  Optom Vis Sci       Date:  2005-10       Impact factor: 1.973

4.  Corneal thickness measurements in normal and keratoconic eyes: Pentacam comprehensive eye scanner versus noncontact specular microscopy and ultrasound pachymetry.

Authors:  Omür Ozlenen Uçakhan; Muhip Ozkan; Ayfer Kanpolat
Journal:  J Cataract Refract Surg       Date:  2006-06       Impact factor: 3.351

5.  Changes in the anterior chamber configuration after small-incision cataract surgery with posterior chamber intraocular lens implantation.

Authors:  Y Kurimoto; M Park; H Sakaue; T Kondo
Journal:  Am J Ophthalmol       Date:  1997-12       Impact factor: 5.258

6.  Risk factors for corneal endothelial injury during phacoemulsification.

Authors:  K Hayashi; H Hayashi; F Nakao; F Hayashi
Journal:  J Cataract Refract Surg       Date:  1996-10       Impact factor: 3.351

7.  Local corneal thickness changes after small-incision cataract surgery.

Authors:  Matthias Bolz; Stefan Sacu; Wolfgang Drexler; Oliver Findl
Journal:  J Cataract Refract Surg       Date:  2006-10       Impact factor: 3.351

8.  Identification of free radicals produced during phacoemulsification.

Authors:  M D Cameron; J F Poyer; S D Aust
Journal:  J Cataract Refract Surg       Date:  2001-03       Impact factor: 3.351

9.  Comparison of three methods of measuring corneal thickness and anterior chamber depth.

Authors:  Wolf Buehl; Danijela Stojanac; Stefan Sacu; Wolfgang Drexler; Oliver Findl
Journal:  Am J Ophthalmol       Date:  2006-01       Impact factor: 5.258

10.  To test or not to test: Preliminary assessment of normality when comparing two independent samples.

Authors:  Justine Rochon; Matthias Gondan; Meinhard Kieser
Journal:  BMC Med Res Methodol       Date:  2012-06-19       Impact factor: 4.615

View more
  1 in total

1.  Monitoring of central corneal thickness after phacoemulsification-comparison of statical and rotating Scheimpflug pachymetry, and spectral-domain OCT.

Authors:  Daniel M Handzel; Carsten H Meyer; Alfred Wegener
Journal:  Int J Ophthalmol       Date:  2022-08-18       Impact factor: 1.645

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.