Literature DB >> 26039419

Tracking Changes in Cardiac Output: Statistical Considerations on the 4-Quadrant Plot and the Polar Plot Methodology.

Bernd Saugel1, Oliver Grothe, Julia Y Wagner.   

Abstract

When comparing 2 technologies for measuring hemodynamic parameters with regard to their ability to track changes, 2 graphical tools are omnipresent in the literature: the 4-quadrant plot and the polar plot recently proposed by Critchley et al. The polar plot is thought to be the more advanced statistical tool, but care should be taken when it comes to its interpretation. The polar plot excludes possibly important measurements from the data. The polar plot transforms the data nonlinearily, which may prevent it from being seen clearly. In this article, we compare the 4-quadrant and the polar plot in detail and thoroughly describe advantages and limitations of each. We also discuss pitfalls concerning the methods to prepare the researcher for the sound use of both methods. Finally, we briefly revisit the Bland-Altman plot for the use in this context.

Mesh:

Year:  2015        PMID: 26039419     DOI: 10.1213/ANE.0000000000000725

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  38 in total

1.  How to "validate" newly developed cardiac output monitoring devices.

Authors:  J J Vos; T W L Scheeren
Journal:  J Clin Monit Comput       Date:  2015-10-13       Impact factor: 2.502

Review 2.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

3.  Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.

Authors:  M Sanders; S Servaas; C Slagt
Journal:  J Clin Monit Comput       Date:  2019-06-07       Impact factor: 2.502

4.  Cardiac output monitoring: less invasiveness, less accuracy?

Authors:  Bernd Saugel; Julia Y Wagner; Thomas W L Scheeren
Journal:  J Clin Monit Comput       Date:  2016-06-17       Impact factor: 2.502

5.  Innovative noninvasive hemodynamic monitoring: curb your enthusiasm after initial validation studies and evaluate the technologies' clinical applicability.

Authors:  Bernd Saugel; Julia Y Wagner
Journal:  J Clin Monit Comput       Date:  2016-02-24       Impact factor: 2.502

6.  Estimated continuous cardiac output based on pulse wave transit time in off-pump coronary artery bypass grafting: a comparison with transpulmonary thermodilution.

Authors:  Alexey A Smetkin; Ayyaz Hussain; Evgenia V Fot; Viktor I Zakharov; Natalia N Izotova; Angelika S Yudina; Zinaida A Dityateva; Yanina V Gromova; Vsevolod V Kuzkov; Lars J Bjertnæs; Mikhail Y Kirov
Journal:  J Clin Monit Comput       Date:  2016-03-07       Impact factor: 2.502

7.  Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement.

Authors:  Jarkko Harju; Antti Vehkaoja; Pekka Kumpulainen; Stefano Campadello; Ville Lindroos; Arvi Yli-Hankala; Niku Oksala
Journal:  J Clin Monit Comput       Date:  2017-01-19       Impact factor: 2.502

8.  A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients.

Authors:  Julia Y Wagner; Annmarie Körner; Leonie Schulte-Uentrop; Mathias Kubik; Hermann Reichenspurner; Stefan Kluge; Daniel A Reuter; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2017-05-24       Impact factor: 2.502

9.  Comparison of stroke volume measurements during hemodialysis using bioimpedance cardiography and echocardiography.

Authors:  Michael J Germain; Jyovani Joubert; Daniel O'Grady; Brian H Nathanson; Yossi Chait; Nathan W Levin
Journal:  Hemodial Int       Date:  2017-08-10       Impact factor: 1.812

10.  Comparison of stroke volumes assessed by three-dimensional echocardiography and transpulmonary thermodilution in a pediatric animal model.

Authors:  Katharina Linden; Dennis Ladage; Oliver Dewald; Eva Gatzweiler; Andrea Pieper; Matthias Seehase; Georg Daniel Duerr; Johannes Breuer; Ulrike Herberg
Journal:  J Clin Monit Comput       Date:  2016-02-17       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.