Literature DB >> 26002122

Dosimetric benefit of adaptive re-planning in pancreatic cancer stereotactic body radiotherapy.

Yongbao Li1, Jeremy D P Hoisak2, Nan Li2, Carrie Jiang2, Zhen Tian3, Quentin Gautier2, Masoud Zarepisheh2, Zhaoxia Wu4, Yaqiang Liu4, Xun Jia3, Jona Hattangadi-Gluth2, Loren K Mell2, Steve Jiang3, James D Murphy5.   

Abstract

Stereotactic body radiotherapy (SBRT) shows promise in unresectable pancreatic cancer, though this treatment modality has high rates of normal tissue toxicity. This study explores the dosimetric utility of daily adaptive re-planning with pancreas SBRT. We used a previously developed supercomputing online re-planning environment (SCORE) to re-plan 10 patients with pancreas SBRT. Tumor and normal tissue contours were deformed from treatment planning computed tomographies (CTs) and transferred to daily cone-beam CT (CBCT) scans before re-optimizing each daily treatment plan. We compared the intended radiation dose, the actual radiation dose, and the optimized radiation dose for the pancreas tumor planning target volume (PTV) and the duodenum. Treatment re-optimization improved coverage of the PTV and reduced dose to the duodenum. Within the PTV, the actual hot spot (volume receiving 110% of the prescription dose) decreased from 4.5% to 0.5% after daily adaptive re-planning. Within the duodenum, the volume receiving the prescription dose decreased from 0.9% to 0.3% after re-planning. It is noteworthy that variation in the amount of air within a patient׳s stomach substantially changed dose to the PTV. Adaptive re-planning with pancreas SBRT has the ability to improve dose to the tumor and decrease dose to the nearby duodenum, thereby reducing the risk of toxicity.
Copyright © 2015 American Association of Medical Dosimetrists. All rights reserved.

Entities:  

Keywords:  CBCT; Interfraction anatomic changes; Online adaptive re-planning; Pancreatic cancer; SBRT

Mesh:

Year:  2015        PMID: 26002122     DOI: 10.1016/j.meddos.2015.04.002

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  12 in total

1.  Dosimetric parameters correlate with duodenal histopathologic damage after stereotactic body radiotherapy for pancreatic cancer: Secondary analysis of a prospective clinical trial.

Authors:  Vivek Verma; Audrey J Lazenby; Dandan Zheng; Abhijeet R Bhirud; Quan P Ly; Chandrakanth Are; Aaron R Sasson; Chi Lin
Journal:  Radiother Oncol       Date:  2017-01-12       Impact factor: 6.280

2.  Feasibility and reproducibility of substituting oral contrast with water for duodenal volume delineation in patients undergoing pancreatic stereotactic body radiotherapy.

Authors:  Guangyin Wu; Vivek Verma; Matthias F Haefner; Sicong Li; Chi Lin
Journal:  J Gastrointest Oncol       Date:  2017-08

3.  Dosimetric impact of gastrointestinal air column in radiation treatment of pancreatic cancer.

Authors:  Neil C Estabrook; Jonathan B Corn; Marvene M Ewing; Higinia R Cardenes; Indra J Das
Journal:  Br J Radiol       Date:  2017-12-22       Impact factor: 3.039

4.  Quantifying Allowable Motion to Achieve Safe Dose Escalation in Pancreatic SBRT.

Authors:  Yijun Ding; Warren G Campbell; Moyed Miften; Yevgeniy Vinogradskiy; Karyn A Goodman; Tracey Schefter; Bernard L Jones
Journal:  Pract Radiat Oncol       Date:  2019-04-02

5.  General and custom deep learning autosegmentation models for organs in head and neck, abdomen, and male pelvis.

Authors:  Asma Amjad; Jiaofeng Xu; Dan Thill; Colleen Lawton; William Hall; Musaddiq J Awan; Monica Shukla; Beth A Erickson; X Allen Li
Journal:  Med Phys       Date:  2022-02-07       Impact factor: 4.071

6.  Dosimetric Uncertainties Resulting From Interfractional Anatomic Variations for Patients Receiving Pancreas Stereotactic Body Radiation Therapy and Cone Beam Computed Tomography Image Guidance.

Authors:  Joshua S Niedzielski; Yufei Liu; Sylvia S W Ng; Rachael M Martin; Luis A Perles; Sam Beddar; Neal Rebueno; Eugene J Koay; Cullen Taniguchi; Emma B Holliday; Prajnan Das; Grace L Smith; Bruce D Minsky; Ethan B Ludmir; Joseph M Herman; Albert Koong; Gabriel O Sawakuchi
Journal:  Int J Radiat Oncol Biol Phys       Date:  2021-08-13       Impact factor: 7.038

7.  Synthetic CT-aided multiorgan segmentation for CBCT-guided adaptive pancreatic radiotherapy.

Authors:  Xianjin Dai; Yang Lei; Jacob Wynne; James Janopaul-Naylor; Tonghe Wang; Justin Roper; Walter J Curran; Tian Liu; Pretesh Patel; Xiaofeng Yang
Journal:  Med Phys       Date:  2021-10-13       Impact factor: 4.071

Review 8.  Stereotactic radiotherapy of pancreatic cancer: a systematic review on pain relief.

Authors:  Milly Buwenge; Gabriella Macchia; Alessandra Arcelli; Rezarta Frakulli; Lorenzo Fuccio; Sara Guerri; Elisa Grassi; Silvia Cammelli; Francesco Cellini; Alessio G Morganti
Journal:  J Pain Res       Date:  2018-10-04       Impact factor: 3.133

9.  Technical Assessment of an Automated Treatment Planning on Dose Escalation of Pancreas Stereotactic Body Radiotherapy.

Authors:  Shuo Wang; Dandan Zheng; Chi Lin; Yu Lei; Vivek Verma; April Smith; Rongtao Ma; Charles A Enke; Sumin Zhou
Journal:  Technol Cancer Res Treat       Date:  2019-01-01

10.  Dosimetric effects of anatomical changes during fractionated photon radiation therapy in pancreatic cancer patients.

Authors:  Astrid van der Horst; Antonetta C Houweling; Geertjan van Tienhoven; Jorrit Visser; Arjan Bel
Journal:  J Appl Clin Med Phys       Date:  2017-10-04       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.