Dosimetric impact of gastrointestinal air column in radiation treatment of pancreatic cancer.

Neil C Estabrook1, Jonathan B Corn1, Marvene M Ewing2, Higinia R Cardenes3, Indra J Das4.   

Abstract

OBJECTIVE: Dosimetric evaluation of air column in gastrointestinal (GI) structures in intensity modulated radiation therapy (IMRT) of pancreatic cancer.
METHODS: Nine sequential patients were retrospectively chosen for dosimetric analysis of air column in the GI apparatus in pancreatic cancer using cone beam CT (CBCT). The four-dimensional CT (4DCT) was used for target and organs at risk (OARs) and non-coplanar IMRT was used for treatment. Once a week, these patients underwent CBCT for air filling, isocentre verification and dose calculations retrospectively.
RESULTS: Abdominal air column variation was as great as ±80% between weekly CBCT and 4DCT. Even with such a large air column in the treatment path for pancreatic cancer, changes in anteroposterior dimension were minimal (2.8%). Using IMRT, variations in air column did not correlate dosimetrically with large changes in target volume. An average dosimetric deviation of mere -3.3% and a maximum of -5.5% was observed.
CONCLUSION: CBCT revealed large air column in GI structures; however, its impact is minimal for target coverage. Because of the inherent advantage of segmentation in IMRT, where only a small fraction of a given beam passes through the air column, this technique might have an advantage over 3DCRT in treating upper GI malignancies where the daily air column can have significant impact. Advances in knowledge: Radiation treatment of pancreatic cancer has significant challenges due to positioning, imaging of soft tissues and variability of air column in bowels. The dosimetric impact of variable air column is retrospectively studied using CBCT. Even though, the volume of air column changes by ± 80%, its dosimetric impact in IMRT is minimum.

Entities:  

Mesh:

Year:  2017        PMID: 29166133      PMCID: PMC5965473          DOI: 10.1259/bjr.20170512

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  30 in total

1.  Dose calculation on kV cone beam CT images: an investigation of the Hu-density conversion stability and dose accuracy using the site-specific calibration.

Authors:  Yi Rong; Jennifer Smilowitz; Dinesh Tewatia; Wolfgang A Tomé; Bhudatt Paliwal
Journal:  Med Dosim       Date:  2009-07-15       Impact factor: 1.482

2.  Characterization and management of interfractional anatomic changes for pancreatic cancer radiotherapy.

Authors:  Feng Liu; Beth Erickson; Cheng Peng; X Allen Li
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-03-19       Impact factor: 7.038

3.  Intensity-modulated radiation therapy in the treatment of gastric cancer: early clinical outcome and dosimetric comparison with conventional techniques.

Authors:  M T Milano; M C Garofalo; S J Chmura; K Farrey; C Rash; R Heimann; A B Jani
Journal:  Br J Radiol       Date:  2006-06       Impact factor: 3.039

4.  Dose calculation and treatment plan optimization including imaging dose from kilovoltage cone beam computed tomography.

Authors:  Parham Alaei; Emiliano Spezi; Margaret Reynolds
Journal:  Acta Oncol       Date:  2014-01-17       Impact factor: 4.089

Review 5.  Comparison of toxicity after IMRT and 3D-conformal radiotherapy for patients with pancreatic cancer - a systematic review.

Authors:  Martin-Immanuel Bittner; Anca-Ligia Grosu; Thomas B Brunner
Journal:  Radiother Oncol       Date:  2014-12-11       Impact factor: 6.280

6.  Intrafractional gastric motion and interfractional stomach deformity during radiation therapy.

Authors:  Miho Watanabe; Koichi Isobe; Haduki Takisima; Takashi Uno; Naoyuki Ueno; Hiroyuki Kawakami; Naoyuki Shigematsu; Miki Yamashita; Hisao Ito
Journal:  Radiother Oncol       Date:  2008-01-22       Impact factor: 6.280

7.  A study on adaptive IMRT treatment planning using kV cone-beam CT.

Authors:  George X Ding; Dennis M Duggan; Charles W Coffey; Matthew Deeley; Dennis E Hallahan; Anthony Cmelak; Arnold Malcolm
Journal:  Radiother Oncol       Date:  2007-08-20       Impact factor: 6.280

Review 8.  Upper abdominal malignancies: intensity-modulated radiation therapy.

Authors:  Mojgan Taremi; Jolie Ringash; Laura A Dawson
Journal:  Front Radiat Ther Oncol       Date:  2007

Review 9.  Computed tomography imaging parameters for inhomogeneity correction in radiation treatment planning.

Authors:  Indra J Das; Chee-Wai Cheng; Minsong Cao; Peter A S Johnstone
Journal:  J Med Phys       Date:  2016 Jan-Mar

10.  Effects of interportal error on dose distribution in patients undergoing breath-holding intensity-modulated radiotherapy for pancreatic cancer: evaluation of a new treatment planning method.

Authors:  Toru Takakura; Mitsuhiro Nakamura; Keiko Shibuya; Manabu Nakata; Akira Nakamura; Yukinori Matsuo; Takehiro Shiinoki; Kyoji Higashimura; Teruki Teshima; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

View more
  2 in total

1.  Dosimetric effect of the intestinal gas of online adaptive stereotactic body radiotherapy on target and critical organs without online electron density correction for pancreatic cancer.

Authors:  Chen Su; Hiroyuki Okamoto; Shie Nishioka; Tatsuya Sakasai; Daisuke Fujiyama; Yuki Miura; Yuki Tsunoda; Junichi Kuwahara; Satoshi Nakamura; Kotaro Iijima; Takahito Chiba; Keita Kaga; Mihiro Takemori; Hiroki Nakayama; Shouichi Katsuta; Koji Inaba; Hiroshi Igaki; Yuko Nakayama; Jun Itami
Journal:  Br J Radiol       Date:  2021-02-05       Impact factor: 3.039

2.  Quantifying and Assessing the Dosimetric Impact of Changing Gas Volumes Throughout the Course of VMAT Radiation Therapy of Upper Gastrointestinal Tumors.

Authors:  Joshua Scott; Kylie Dundas; Yolanda Surjan; Odette King; Sankar Arumugam; Shrikant Deshpande; Mark Udovitch; Mark Lee
Journal:  Adv Radiat Oncol       Date:  2021-01-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.