Literature DB >> 25992468

Utilizing Microchip Capillary Electrophoresis Electrospray Ionization for Hydrogen Exchange Mass Spectrometry.

William A Black, Bradley B Stocks1, J Scott Mellors, John R Engen1, J Michael Ramsey.   

Abstract

Hydrogen exchange (HX) mass spectrometry (MS) of complex mixtures requires a fast, reproducible, and high peak capacity separation prior to MS detection. The current paradigm relies on liquid chromatography (LC) with fast gradients performed at low temperatures to minimize back exchange. Unfortunately, under these conditions, the efficiency of LC is limited due to resistance to mass transfer, reducing the capability to analyze complex samples. Capillary electrophoresis (CE), on the other hand, is not limited by resistance to mass transfer, enabling very rapid separations that are not adversely affected by low temperature. Previously, we have demonstrated an integrated microfluidic device coupling CE with electrospray ionization (ESI) capable of very rapid and high efficiency separations. In this work, we demonstrate the utility of this microchip CE-ESI device for HX MS. High speed CE-ESI of a bovine hemoglobin pepsin digestion was performed in 1 min with a peak capacity of 62 versus a similar LC separation performed in 7 min with peak capacity of 31. A room temperature CE method performed in 1.25 min provided similar deuterium retention as an 8.5 min LC method conducted at 0 °C. Separation of a complex mixture with CE was done with considerably better speed and nearly triple the peak capacity than the equivalent separation by LC. Overall, the results indicate the potential utility of microchip CE-ESI for HX MS.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25992468      PMCID: PMC4470751          DOI: 10.1021/acs.analchem.5b01179

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  33 in total

1.  Development of multi-ESI-sprayer, multi-atmospheric-pressure-inlet mass spectrometry and its application to accurate mass measurement using time-of-flight mass spectrometry.

Authors:  L Jiang; M Moini
Journal:  Anal Chem       Date:  2000-01-01       Impact factor: 6.986

2.  Flow injection of the lock mass standard for accurate mass measurement in electrospray ionization time-of-flight mass spectrometry coupled with liquid chromatography.

Authors:  Laurence Charles
Journal:  Rapid Commun Mass Spectrom       Date:  2003       Impact factor: 2.419

Review 3.  Multidimensional LC-LC and LC-CE for high-resolution separations of biological molecules.

Authors:  Charles R Evans; James W Jorgenson
Journal:  Anal Bioanal Chem       Date:  2004-02-12       Impact factor: 4.142

Review 4.  Accurate mass measurement for the determination of elemental formula--a tutorial.

Authors:  Anthony W T Bristow
Journal:  Mass Spectrom Rev       Date:  2006 Jan-Feb       Impact factor: 10.946

5.  Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatography.

Authors:  Martin Gilar; Amy E Daly; Marianna Kele; Uwe D Neue; John C Gebler
Journal:  J Chromatogr A       Date:  2004-12-24       Impact factor: 4.759

6.  The cell as a collection of protein machines: preparing the next generation of molecular biologists.

Authors:  B Alberts
Journal:  Cell       Date:  1998-02-06       Impact factor: 41.582

7.  Protein hydrogen exchange studied by the fragment separation method.

Authors:  J J Englander; J R Rogero; S W Englander
Journal:  Anal Biochem       Date:  1985-05-15       Impact factor: 3.365

8.  Free-zone electrophoresis in glass capillaries.

Authors:  J W Jorgenson; K D Lukacs
Journal:  Clin Chem       Date:  1981-09       Impact factor: 8.327

Review 9.  Hydrogen exchange mass spectrometry: what is it and what can it tell us?

Authors:  Sean R Marcsisin; John R Engen
Journal:  Anal Bioanal Chem       Date:  2010-03-01       Impact factor: 4.142

10.  Fully integrated glass microfluidic device for performing high-efficiency capillary electrophoresis and electrospray ionization mass spectrometry.

Authors:  J S Mellors; V Gorbounov; R S Ramsey; J M Ramsey
Journal:  Anal Chem       Date:  2008-08-13       Impact factor: 6.986

View more
  7 in total

1.  Fabrication of anti-protein-fouling poly(ethylene glycol) microfluidic chip electrophoresis by sandwich photolithography.

Authors:  Hailin Cong; Xiaodan Xu; Bing Yu; Huwei Liu; Hua Yuan
Journal:  Biomicrofluidics       Date:  2016-07-19       Impact factor: 2.800

2.  Fabrication of universal serial bus flash disk type microfluidic chip electrophoresis and application for protein analysis under ultra low voltage.

Authors:  Hailin Cong; Xiaodan Xu; Bing Yu; Huwei Liu; Hua Yuan
Journal:  Biomicrofluidics       Date:  2016-03-15       Impact factor: 2.800

Review 3.  Recent trends of capillary electrophoresis-mass spectrometry in proteomics research.

Authors:  Fabio P Gomes; John R Yates
Journal:  Mass Spectrom Rev       Date:  2019-08-12       Impact factor: 10.946

Review 4.  Advances in Hydrogen/Deuterium Exchange Mass Spectrometry and the Pursuit of Challenging Biological Systems.

Authors:  Ellie I James; Taylor A Murphree; Clint Vorauer; John R Engen; Miklos Guttman
Journal:  Chem Rev       Date:  2021-09-07       Impact factor: 72.087

5.  Label-Free, In-Solution Screening of Peptide Libraries for Binding to Protein Targets Using Hydrogen Exchange Mass Spectrometry.

Authors:  Walid S Maaty; David D Weis
Journal:  J Am Chem Soc       Date:  2016-01-21       Impact factor: 15.419

6.  On-line pre-treatment, separation, and nanoelectrospray mass spectrometric determinations for pesticide metabolites and peptides based on a modular microfluidic platform.

Authors:  Yinyin Hao; Yajing Bao; Xueying Huang; Yijun Hu; Bo Xiong
Journal:  RSC Adv       Date:  2018-11-28       Impact factor: 3.361

7.  Seven perspectives on GPCR H/D-exchange proteomics methods.

Authors:  Xi Zhang
Journal:  F1000Res       Date:  2017-01-30
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.