| Literature DB >> 25986069 |
Tao Zhang1, Zhi-Wen Liang2, Jun Han3, Jian-Ping Bi4, Zhi-Yong Yang5, Hong Ma6.
Abstract
BACKGROUND: The objective of this study was to compare the dose distributions of RapidArc (RA), static gantry intensity-modulated radiotherapy (IMRT), and three-dimensional conformal radiotherapy (3DCRT) as adjuvant radiotherapy modalities for the treatment of gastric cancer.Entities:
Mesh:
Year: 2015 PMID: 25986069 PMCID: PMC4438524 DOI: 10.1186/s13014-015-0420-x
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Summary of the DVH parameters examined
| Parameters | 3DCRT Mean ± SD | IMRT Mean ± SD | RA Mean ± SD | |
|---|---|---|---|---|
| PTV | D1% (Gy) | 49.9 ± 0.29 | 48.2 ± 0.17 | 48.4 ± 0.24 |
| D99% (Gy) | 40.5 ± 0.43 | 40.3 ± 0.41 | 40.1 ± 0.37 | |
| V95% (%) | 96.6 ± 0.61 | 98.9 ± 0.33 | 98.5 ± 0.62 | |
| V107% (%) | 13.6 ± 3.7 | 1.02 ± 0.01 | 1.02 ± 0.01 | |
| EUD (Gy) | 47.3 ± 0.09 | 46.8 ± 1.45 | 46.4 ± 0.06 | |
| HI | 0.1 ± 0.01 | 0.05 ± 0.01 | 0.07 ± 0.01 | |
| CI | 0.71 ± 0.02 | 0.89 ± 0.04 | 0.90 ± 0.02 | |
| Normal liver | Dmean (Gy) | 17.6 ± 0.82 | 14.2 ± 0.73 | 15.3 ± 1.1 |
| V30 (%) | 12.3 ± 1.6 | 12.7 ± 1.3 | 6.90 ± 1.4 | |
| Left kidney | Dmean (Gy) | 13.2 ± 1.21 | 15.3 ± 0.63 | 14.1 ± 0.61 |
| V20 (%) | 29.9 ± 2.5 | 27.7 ± 1.8 | 22.4 ± 3.6 | |
| Right kidney | Dmean (Gy) | 11.9 ± 1.4 | 13.5 ± 0.65 | 12.2 ± 0.90 |
| V20 (%) | 19.2 ± 1.1 | 16.2 ± 1.1 | 12.7 ± 1.3 | |
| Small bowel | Dmean (Gy) | 13.1 ± 0.83 | 12.4 ± 0.39 | 13.1 ± 0.76 |
| V30 (%) | 17.2 ± 0.61 | 16.5 ± 0.67 | 15.6 ± 0.83 | |
| V40 (%) | 11.0 ± 0.38 | 9.78 ± 0.93 | 9.15 ± 0.44 | |
| Spinal cord | D1% (Gy) | 33.0 ± 0.74 | 31.0 ± 0.29 | 27.8 ± 0.75 |
| MU | 250 ± 3.4 | 694 ± 3.9 | 399 ± 6.8 | |
Abbreviations: 3DCRT: 3D conformal radiation therapy; IMRT: intensity-modulated radiation therapy; RA: RapidArc; PTV: planned tumor volume; Dn%: dose received by n% of the volume; Gy: Gray (unit); Vx%: the volume receiving ≥ x% of the prescribed dose; EUD: equivalent uniform dose; HI: homogeneity index; CI: conformity index; Dmean: the mean dose for the organ; Vn: the volume receiving n dose of radiation (Gy); MU: monitor units; EUD: equivalent uniform dose
Differences among the three methods with regard to the DVH parameters
| Parameters |
| ||||
|---|---|---|---|---|---|
| Overall | 3DCRT vs. IMRT | 3DCRT vs. RA | IMRT vs. RA | ||
| PTV | D1% (Gy) | 0.003 | 3DCRT > IMRT** | 3DCRT > RA** | − |
| D99% (Gy) | 0.803 | − | − | − | |
| V95% (%) | 0.533 | − | − | − | |
| V107% (%) | 0.005 | 3DCRT > IMRT* | 3DCRT > RA* | − | |
| EUD (Gy) | 0.012 | 3DCRT > IMRT* | 3DCRT > RA* | _ | |
| HI | 0.03 | 3DCRT > IMRT* | 3DCRT > RA* | − | |
| CI | 0.001 | 3DCRT < IMRT* | 3DCRT < RA* | − | |
| Normal liver | Dmean (Gy) | 0.058 | 3DCRT > IMRT** | − | − |
| V30 (%) | 0.006 | − | 3DCRT > RA** | IMRT > RA** | |
| Left kidney | Dmean (Gy) | 0.335 | − | − | − |
| V20 (%) | 0.137 | − | 3DCRT > RA* | − | |
| Right kidney | Dmean (Gy) | 0.912 | − | − | − |
| V20 (%) | 0.005 | − | 3DCRT > RA** | − | |
| Small bowel | Dmean (Gy) | 0.657 | − | − | − |
| V30 (%) | 0.075 | − | − | − | |
| V40 (%) | 0.453 | − | − | − | |
| Spinal cord | D1% (Gy) | 0.011 | − | 3DCRT > RA* | IMRT > RA* |
| MU | 0.001 | IMRT > 3DCRT** | IMRT > RA** | ||
Abbreviations: 3DCRT: 3D conformal radiation therapy; IMRT: intensity-modulated radiation therapy; RA: RapidArc; PTV: planned tumor volume; Dn%: dose received by n% of the volume; Gy: Gray (unit); Vx%: the volume receiving ≥ x% of the prescribed dose; EUD: equivalent uniform dose; HI: homogeneity index; CI: conformity index; Dmean: the mean dose for the organ; Vn: the volume receiving n dose of radiation (Gy); MU: monitor units
*P <0.05; **P <0.01
Fig. 1Comparison of the PTV isodose distributions achieved with 3DCRT, IMRT, and RapidArc adjuvant radiotherapy modalities
Fig. 2Mean dose volume histograms for PTV, CTV, OAR, and healthy tissue for global analysis according to treatment plan. 3DCRT: 3D conformal radiation therapy (blue); IMRT: intensity-modulated radiation therapy (red); RapidArc: double-arc RapidArc (green)