Literature DB >> 23791504

Single-arc volumetric-modulated arc therapy (sVMAT) as adjuvant treatment for gastric cancer: dosimetric comparisons with three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT).

Xin Wang1, Guangjun Li, Yingjie Zhang, Sen Bai, Feng Xu, Yuquan Wei, Youling Gong.   

Abstract

To compare the dosimetric differences between the single-arc volumetric-modulated arc therapy (sVMAT), 3-dimensional conformal radiotherapy (3D-CRT), and intensity-modulated radiotherapy (IMRT) techniques in treatment planning for gastric cancer as adjuvant radiotherapy. Twelve patients were retrospectively analyzed. In each patient's case, the parameters were compared based on the dose-volume histogram (DVH) of the sVMAT, 3D-CRT, and IMRT plans, respectively. Three techniques showed similar target dose coverage. The maximum and mean doses of the target were significantly higher in the sVMAT plans than that in 3D-CRT plans and in the 3D-CRT/IMRT plans, respectively, but these differences were clinically acceptable. The IMRT and sVMAT plans successfully achieved better target dose conformity, reduced the V20/30, and mean dose of the left kidney, as well as the V20/30 of the liver, compared with the 3D-CRT plans. And the sVMAT technique reduced the V20 of the liver much significantly. Although the maximum dose of the spinal cord were much higher in the IMRT and sVMAT plans, respectively (mean 36.4 vs 39.5 and 40.6Gy), these data were still under the constraints. Not much difference was found in the analysis of the parameters of the right kidney, intestine, and heart. The IMRT and sVMAT plans achieved similar dose distribution to the target, but superior to the 3D-CRT plans, in adjuvant radiotherapy for gastric cancer. The sVMAT technique improved the dose sparings of the left kidney and liver, compared with the 3D-CRT technique, but showed few dosimetric advantages over the IMRT technique. Studies are warranted to evaluate the clinical benefits of the VMAT treatment for patients with gastric cancer after surgery in the future.
© 2013 American Association of Medical Dosimetrists.

Entities:  

Keywords:  Dosimetric comparison; Gastric cancer; Intensity-modulated radiotherapy; Three-dimensional conformal radiotherapy; Volumetric-modulated arc therapy

Mesh:

Year:  2013        PMID: 23791504     DOI: 10.1016/j.meddos.2013.04.007

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  15 in total

1.  The outcomes of radiotherapy and factors that predict overall survival in elderly patients with esophageal squamous cell carcinoma.

Authors:  H Yin; M E; H Zhang; C Wang
Journal:  Clin Transl Oncol       Date:  2017-01-13       Impact factor: 3.405

Review 2.  Chemoradiation for gastric cancer: controversies, updates and novel techniques.

Authors:  M Fan; W Hu; Z Zhang
Journal:  Br J Radiol       Date:  2015-04-01       Impact factor: 3.039

3.  Comparison of dosimetric parameters and toxicity in esophageal cancer patients undergoing 3D conformal radiotherapy or VMAT.

Authors:  Stefan Münch; Sylvia Aichmeier; Alexander Hapfelmeier; Marciana-Nona Duma; Markus Oechsner; Marcus Feith; Stephanie E Combs; Daniel Habermehl
Journal:  Strahlenther Onkol       Date:  2016-07-14       Impact factor: 3.621

4.  Can we obtain planning goals for conformal techniques in neoadjuvant and adjuvant radiochemotherapy for gastric cancer patients?

Authors:  Wojciech Leszczyński; Paweł Polanowski; Paulina Leszczyńska; Leszek Hawrylewicz; Iwona Brąclik; Rafał Kawczyński; Jerzy Wydmański
Journal:  Rep Pract Oncol Radiother       Date:  2016-02-08

5.  Dosimetric and clinical toxicity comparison of critical organ preservation with three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and RapidArc for the treatment of locally advanced cancer of the pancreatic head.

Authors:  L Jin; R Wang; S Jiang; J Yue; T Liu; X Dou; K Zhu; R Feng; X Xu; D Chen; Y Yin
Journal:  Curr Oncol       Date:  2016-02-18       Impact factor: 3.677

6.  Dosimetric comparison of 3-dimensional conformal radiotherapy, volumetric modulated arc therapy, and helical tomotherapy for postoperative gastric cancer patients.

Authors:  Cem Onal; Yemliha Dölek; Berna Akkuş Yıldırım
Journal:  Jpn J Radiol       Date:  2017-11-03       Impact factor: 2.374

7.  Double-arc volumetric modulated therapy improves dose distribution compared to static gantry IMRT and 3D conformal radiotherapy for adjuvant therapy of gastric cancer.

Authors:  Tao Zhang; Zhi-Wen Liang; Jun Han; Jian-Ping Bi; Zhi-Yong Yang; Hong Ma
Journal:  Radiat Oncol       Date:  2015-05-19       Impact factor: 3.481

8.  Delineation of Margins for the Planning Target Volume (PTV) for Image-Guided Radiotherapy (IGRT) of Gastric Cancer Based on Intrafraction Motion

Authors:  Paulina Leszczyńska; Wojciech Leszczyński; Jerzy Wydmański; Agnieszka Namysł Kaletka; Andrzej Tukiendorf; Leszek Hawrylewicz
Journal:  Asian Pac J Cancer Prev       Date:  2017-01-01

9.  Dosimetric comparison of intensity modulated and volumetric arc radiation therapy for gastric cancer.

Authors:  Zhiping Li; Jianshuang Zeng; Zi Wang; Hong Zhu; Yuquan Wei
Journal:  Oncol Lett       Date:  2014-07-18       Impact factor: 2.967

10.  Prediction of radiosensitive patients with gastric cancer by developing gene signature.

Authors:  Jin Zhou; Xiaoyu Wu; Gang Li; Xin Gao; Min Zhai; Weichang Chen; Huagang Hu; Zaixiang Tang
Journal:  Int J Oncol       Date:  2017-08-30       Impact factor: 5.650

View more