Literature DB >> 25981119

Effects of mydriasis and miosis on kinetic perimetry findings in normal participants.

Kazunori Hirasawa1, Nobuyuki Shoji, Chieko Kobashi, Ayaka Yamanashi.   

Abstract

PURPOSE: To evaluate the effects of pharmacologically induced mydriasis and miosis on kinetic perimetry findings in normal participants.
METHODS: Thirty-eight eyes of 38 healthy young participants underwent kinetic perimetry (Octopus 900 perimeter) with III4e, I4e, I3e, I2e, and I1e stimuli. For each participant, 24 predetermined meridians with 15° intervals were automatically tested with a velocity of 3°/s under normal, mydriatic, and miotic conditions. Mydriasis and miosis were induced by one drop of 0.4 % tropicamide and 2 % pilocarpine hydrochloride, respectively. The isopter area and kinetic sensitivity were compared between the three pupil conditions.
RESULTS: The average pupil size in the normal condition was 5.6 ± 0.9 mm, and it significantly increased to 8.5 ± 0.7 mm after mydriasis (p < 0.01) and decreased to 3.4 ± 0.8 mm after miosis (p < 0.01). Compared to the normal pupil, the isopter area of the dilated pupil was not significantly different under the III4e stimulus; however, it significantly decreased under the I4e, I3e, I2e, and I1e stimuli (p < 0.01). Compared to the normal pupil, the isopter area of the constricted pupil significantly decreased (p < 0.01) with the III4e stimulus and significantly increased with the I3e and I2e stimuli (p < 0.05).
CONCLUSIONS: For both pupil conditions, kinetic sensitivity at each meridian showed a similar trend to the isopter area under each stimulus. The isopter area of the dilated pupil generally decreased, whereas the isopter area of the constricted pupil showed various findings. Therefore, careful attention should be paid to changes in the isopter area associated with changes in the pupil size.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25981119     DOI: 10.1007/s00417-015-3048-5

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  22 in total

1.  Factors influencing normal perimetric thresholds obtained using the Humphrey Field Analyzer.

Authors:  P R Herse
Journal:  Invest Ophthalmol Vis Sci       Date:  1992-03       Impact factor: 4.799

2.  Effects of pupillary dilation on automated perimetry in normal patients.

Authors:  K A Lindenmuth; G L Skuta; R Rabbani; D C Musch; T J Bergstrom
Journal:  Ophthalmology       Date:  1990-03       Impact factor: 12.079

3.  Evaluation of stimulus velocity in automated kinetic perimetry in young healthy participants.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji; Ayaka Okada; Kana Takano; Seiya Tomioka
Journal:  Vision Res       Date:  2014-04-03       Impact factor: 1.886

4.  Effects of pupillary constriction on automated perimetry in normal eyes.

Authors:  K A Lindenmuth; G L Skuta; R Rabbani; D C Musch
Journal:  Ophthalmology       Date:  1989-09       Impact factor: 12.079

5.  The influence of miotics on the visual field.

Authors:  C W Kee; D H Youn
Journal:  Korean J Ophthalmol       Date:  1987-06

6.  Optimal rates of movement for kinetic perimetry.

Authors:  C A Johnson; J L Keltner
Journal:  Arch Ophthalmol       Date:  1987-01

7.  Pupillary dilation and its effects on automated perimetry results.

Authors:  G R Kudrna; M A Stanley; L A Remington
Journal:  J Am Optom Assoc       Date:  1995-11

8.  An evaluation of the accuracy of community-based perimetry.

Authors:  J D Trobe; P C Acosta; J J Shuster; J P Krischer
Journal:  Am J Ophthalmol       Date:  1980-11       Impact factor: 5.258

9.  The effect of pilocarpine on the visual field in normals.

Authors:  D J McCluskey; J P Douglas; P S O'Connor; K Story; L M Ivy; J S Harvey
Journal:  Ophthalmology       Date:  1986-06       Impact factor: 12.079

10.  The effect of pilocarpine on the glaucomatous visual field.

Authors:  A R Webster; A J Luff; C R Canning; A R Elkington
Journal:  Br J Ophthalmol       Date:  1993-11       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.