Factors influencing normal perimetric thresholds obtained using the Humphrey Field Analyzer.

P R Herse1.   

Abstract

The relationships between dioptric blur, pupil size, retinal eccentricity, and retinal sensitivity were investigated in the central 5 degrees of the visual field in 10 normal subjects using the Humphrey Field Analyzer. Pupil size did not influence the foveal sensitivity or retinal profile in the unblurred condition. The slope of the retinal profile was significantly steeper in the 3 mm pupil size condition (-0.62 dB/degree) than when compared to the 8 mm pupil size condition (-0.34 dB/degree), when averaged over all dioptric blur conditions. The depth of focus for the 3 mm pupil size condition (3.86 diopters) was significantly greater than that found for the 8 mm pupil size condition (1.82 D). The retinal threshold doubling eccentricity (E2) was calculated to be similar to that of grating acuity and contrast sensitivity (3.71). The data suggest that while large depth of focus effects in small pupil sizes appear to reduce the need for accurate refractive error corrections in determining perimetric retinal sensitivities, variations in the slope of the retinal profile under conditions of uncontrolled dioptric blur and pupil size may result in the artifactual sensitivity decreases. Therefore, it is recommended that measurement of pupil size and accurate correction of near refractive errors be performed to minimize the possibility of incorrect detection of central visual field defects.

Entities:  

Mesh:

Year:  1992        PMID: 1544786

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  4 in total

1.  Effects of mydriasis and miosis on kinetic perimetry findings in normal participants.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji; Chieko Kobashi; Ayaka Yamanashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-05-19       Impact factor: 3.117

2.  Influence of uncorrected ametropia on computer-based perimetry in patients with visual field defects and normal subjects.

Authors:  Sandra Jobke; Erich Kasten; Bernhard A Sabel
Journal:  Clin Ophthalmol       Date:  2007-06

3.  Author's reply.

Authors:  Emrullah Beyazyildiz; Özlem Beyazyildiz; Hasan Basri Arifoglu; Aysegül Kocak Altintas; Sükrü Gültekin Köklü
Journal:  Indian J Ophthalmol       Date:  2015-01       Impact factor: 1.848

4.  Clinical Application of Infrared-Light Microperimetry in the Assessment of Scotopic-Eye Sensitivity.

Authors:  Grzegorz Łabuz; Asu Rayamajhi; Julia Usinger; Katarzyna Komar; Patrick Merz; Ramin Khoramnia; Grazyna Palczewska; Krzysztof Palczewski; Gerd U Auffarth
Journal:  Transl Vis Sci Technol       Date:  2020-07-07       Impact factor: 3.283

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.