Literature DB >> 24705075

Evaluation of stimulus velocity in automated kinetic perimetry in young healthy participants.

Kazunori Hirasawa1, Nobuyuki Shoji2, Ayaka Okada3, Kana Takano3, Seiya Tomioka3.   

Abstract

This prospective study aimed to evaluate the stimulus velocity for automated kinetic perimetry based on the test duration, the kinetic sensitivity, and the variability of the kinetic sensitivity in 31 eyes of 31 young healthy participants. Automated kinetic perimetry was performed using an Octopus 900 perimeter with Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. The participants underwent testing at 14 predetermined meridians for each stimulus, with velocities of 2°, 3°, 4°, 5°, and 10°/s; each velocity was tested twice. The test duration, kinetic sensitivity, and variability of kinetic sensitivity were compared among the stimulus velocities. Twenty-nine eyes from 29 participants were analyzed, and two participants were excluded. The test durations at the velocities of 2°, 3°, 4°, 5°, and 10°/s were negatively correlated with the stimulus velocity (p<0.01). The variability of the kinetic sensitivities did not significantly differ among the stimulus velocities. The kinetic sensitivities at 2° and 3°/s did not differ significantly for all stimuli. However, those at 4°/s decreased for III4e, I4e, and I1e (p<0.05), and those at 5° and 10°/s decreased for all stimuli (p<0.05) compared with those at 2° or 3°/s. Although the test durations for each stimulus velocity were negatively correlated with the stimulus velocities, a stimulus velocity of 3° or 4°/s might be recommended for automated kinetic perimetry based on the changes in the kinetic sensitivity. As this study included only young participants, further studies in elderly participants may also be necessary.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Automated kinetic perimetry; Kinetic perimetry; Octopus 900; Perimetry; Stimulus velocity

Mesh:

Year:  2014        PMID: 24705075     DOI: 10.1016/j.visres.2014.03.010

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  2 in total

1.  Effects of mydriasis and miosis on kinetic perimetry findings in normal participants.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji; Chieko Kobashi; Ayaka Yamanashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-05-19       Impact factor: 3.117

2.  Effects of different levels of intraocular stray light on kinetic perimetry findings.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji; Karen Isono; Manami Tsuchiya
Journal:  PLoS One       Date:  2015-05-12       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.