Noninvasive Assessment of Excessive Erythrocytosis as a Screening Method for Chronic Mountain Sickness at High Altitude.

Kaetan J Vyas1, David Danz2, Robert H Gilman3, Robert A Wise1, Fabiola León-Velarde4, J Jaime Miranda5,6, William Checkley1.   

Abstract

Vyas, Kaetan J., David Danz, Robert H. Gilman, Robert A. Wise, Fabiola León-Velarde, J. Jaime Miranda, and William Checkley. Noninvasive assessment of excessive erythrocytosis as a screening method for chronic mountain sickness at high altitude. High Alt Med Biol 16:162-168, 2015.--Globally, over 140 million people are at risk of developing chronic mountain sickness, a common maladaptation to life at high altitude (>2500 meters above sea level). The diagnosis is contingent upon the identification of excessive erythrocytosis (EE). Current best practices to identify EE require a venous blood draw, which is cumbersome for large-scale surveillance. We evaluated two point-of-care biomarkers to screen for EE: noninvasive spot-check tests of total hemoglobin and oxyhemoglobin saturation (Pronto-7, Masimo Corporation). We conducted paired evaluations of total serum hemoglobin from a venous blood draw and noninvasive, spot-check testing of total hemoglobin and oxyhemoglobin saturation with the Pronto-7 in 382 adults aged ≥35 years living in Puno, Peru (3825 meters above sea level). We used the Bland-Altman method to measure agreement between the noninvasive hemoglobin assessment and the gold standard lab hemoglobin analyzer. Mean age was 58.8 years and 47% were male. The Pronto-7 test was unsuccessful in 21 (5%) participants. Limits of agreement between total hemoglobin measured via venous blood draw and the noninvasive, spot-check test ranged from -2.8 g/dL (95% CI -3.0 to -2.5) to 2.5 g/dL (95% CI 2.2 to 2.7), with a bias of -0.2 g/dL (95% CI -0.3 to -0.02) for the difference between total hemoglobin and noninvasive hemoglobin concentrations. Overall, the noninvasive spot-check test of total hemoglobin had a better area under the receiver operating characteristic curve compared to oxyhemoglobin saturation for the identification of EE as measured by a gold standard laboratory hemoglobin analyzer (0.96 vs. 0.82; p<0.001). Best cut-off values to screen for EE with the Pronto 7 were ≥19.9 g/dL in males and ≥17.5 g/dL in females. At these cut-points, sensitivity and specificity were both 92% and 89% for males and females, respectively. A noninvasive, spot-check test of total hemoglobin had low bias and high discrimination for the detection of EE in high altitude Peru, and may be a useful point-of-care tool for large-scale surveillance in high-altitude settings.

Entities:  

Keywords:  chronic mountain sickness; excessive erythrocytosis; noninvasive methods; screening

Mesh:

Substances:

Year:  2015        PMID: 25973777      PMCID: PMC4490741          DOI: 10.1089/ham.2015.0026

Source DB:  PubMed          Journal:  High Alt Med Biol        ISSN: 1527-0297            Impact factor:   1.981


  21 in total

1.  Exercise pathophysiology in patients with chronic mountain sickness exercise in chronic mountain sickness.

Authors:  Herman Groepenhoff; Marieke J Overbeek; Massimiliano Mulè; Mart van der Plas; Paola Argiento; Francisco C Villafuerte; Sophia Beloka; Vitalie Faoro; Jose L Macarlupu; Herve Guenard; Claire de Bisschop; Jean-Benoit Martinot; Rebecca Vanderpool; Dante Penaloza; Robert Naeije
Journal:  Chest       Date:  2012-10       Impact factor: 9.410

Review 2.  Chronic mountain sickness and the heart.

Authors:  Fabiola León-Velarde; Francisco C Villafuerte; Jean-Paul Richalet
Journal:  Prog Cardiovasc Dis       Date:  2010 May-Jun       Impact factor: 8.194

3.  Noninvasive methods for haemoglobin screening in prospective blood donors.

Authors:  A Belardinelli; M Benni; P L Tazzari; P Pagliaro
Journal:  Vox Sang       Date:  2013-04-19       Impact factor: 2.144

4.  Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum hospital, Sudan.

Authors:  Ishag Adam; Samah Ahmed; Mahmoud H Mahmoud; Mohammed I Yassin
Journal:  Diagn Pathol       Date:  2012-03-21       Impact factor: 2.644

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  High serum testosterone levels are associated with excessive erythrocytosis of chronic mountain sickness in men.

Authors:  Gustavo F Gonzales; Manuel Gasco; Vilma Tapia; Cynthia Gonzales-Castañeda
Journal:  Am J Physiol Endocrinol Metab       Date:  2009-03-24       Impact factor: 4.310

7.  Evaluation of point-of-care haemoglobin measuring devices: a comparison of Radical-7™ pulse co-oximetry, HemoCue(®) and laboratory haemoglobin measurements in obstetric patients*.

Authors:  V A Skelton; N Wijayasinghe; S Sharafudeen; A Sange; N S Parry; C Junghans
Journal:  Anaesthesia       Date:  2012-10-22       Impact factor: 6.955

8.  Accuracy of point-of-care-testing (POCT) for determining hemoglobin concentrations.

Authors:  H Gehring; C Hornberger; L Dibbelt; A Rothsigkeit; K Gerlach; J Schumacher; P Schmucker
Journal:  Acta Anaesthesiol Scand       Date:  2002-09       Impact factor: 2.105

9.  Accuracy of noninvasive hemoglobin and invasive point-of-care hemoglobin testing compared with a laboratory analyzer.

Authors:  N Shah; E A Osea; G J Martinez
Journal:  Int J Lab Hematol       Date:  2013-06-27       Impact factor: 2.877

10.  Prevalence of Chronic Mountain Sickness in high altitude districts of Himachal Pradesh.

Authors:  Inderjeet Singh Sahota; Nidhi Singh Panwar
Journal:  Indian J Occup Environ Med       Date:  2013-09
View more
  5 in total

Review 1.  Methods and analyzers for hemoglobin measurement in clinical laboratories and field settings.

Authors:  Ralph D Whitehead; Zuguo Mei; Carine Mapango; Maria Elena D Jefferds
Journal:  Ann N Y Acad Sci       Date:  2019-06-04       Impact factor: 5.691

2.  Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India.

Authors:  Sutapa Bandyopadhyay Neogi; Jyoti Sharma; Shivam Pandey; Nausheen Zaidi; Maitreyee Bhattacharya; Rakhee Kar; Sitanshu Sekhar Kar; Abhishek Purohit; Sanjib Bandyopadhyay; Renu Saxena
Journal:  BMC Health Serv Res       Date:  2020-05-26       Impact factor: 2.655

Review 3.  Towards sustainable partnerships in global health: the case of the CRONICAS Centre of Excellence in Chronic Diseases in Peru.

Authors:  J Jaime Miranda; Antonio Bernabé-Ortiz; Francisco Diez-Canseco; Germán Málaga; María K Cárdenas; Rodrigo M Carrillo-Larco; María Lazo-Porras; Miguel Moscoso-Porras; M Amalia Pesantes; Vilarmina Ponce; Ricardo Araya; David Beran; Peter Busse; Oscar Boggio; William Checkley; Patricia J García; Luis Huicho; Fabiola León-Velarde; Andrés G Lescano; David C Mohr; William Pan; David Peiris; Pablo Perel; Cristina Rabadán-Diehl; Maria Rivera-Chira; Katherine Sacksteder; Liam Smeeth; Antonio J Trujillo; Jonathan C K Wells; Lijing L Yan; Héctor H García; Robert H Gilman
Journal:  Global Health       Date:  2016-06-02       Impact factor: 4.185

4.  Ethnically Tibetan women in Nepal with low hemoglobin concentration have better reproductive outcomes.

Authors:  Jang Ik Cho; Buddha Basnyat; Choongwon Jeong; Anna Di Rienzo; Geoff Childs; Sienna R Craig; Jiayang Sun; Cynthia M Beall
Journal:  Evol Med Public Health       Date:  2017-04-21

5.  Noninvasive hematocrit assessment for cardiovascular magnetic resonance extracellular volume quantification using a point-of-care device and synthetic derivation.

Authors:  Sean Robison; Gauri Rani Karur; Rachel M Wald; Paaladinesh Thavendiranathan; Andrew M Crean; Kate Hanneman
Journal:  J Cardiovasc Magn Reson       Date:  2018-03-15       Impact factor: 5.364

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.