Literature DB >> 27231125

Clinical Evaluation of Fully Automated Elecsys® Syphilis Assay for the Detection of Antibodies of Treponema pallidum.

Dongdong Li1, Jingna An1, Tingting Wang1, Chuanmin Tao2, Lanlan Wang1.   

Abstract

OBJECTIVE: The resurgence of syphilis in recent years has become a serious threat to the public health worldwide, and the serological detection of specific antibodies against Treponema pallidum (TP) remains the most reliable method for laboratory diagnosis of syphilis. The performance of the Elecsys® Syphilis assay, a brand new electrochemiluminescene immunoassay (ECLIA), was assessed by large amounts of samples in this study.
METHODS: In comparison with InTec assay, the Elecsys® Syphilis assay was evaluated in 146 preselected samples from patients with syphilis, 1803 clinical routine samples, and 175 preselected samples from specific populations with reportedly increased rates of false-positive syphilis test results. Discrepancy samples must be investigated by Mikrogen Syphilis recomline assay.
RESULTS: There was an overall agreement of 99.58% between two assays (Kappa = 0.975). The sensitivity and specificity of the Elecsys® Syphilis assay were 100.0% (95% CI, 96.8-100.0%) and 99.8% (95% CI, 99.5-100.0%), respectively. The Elecsys syphilis assay displays better sensitivity (100%), specificity (99.8%), PPV (98.7%), and NPV (100%) in 2124 samples enrolled, compared with the InTec assay.
CONCLUSION: Considering the excellent ease of use and automation, high throughput, and its superior sensitivity, especially in primary syphilis, the Elecsys® Syphilis assay could represent an outstanding choice for screening of syphilis in high-volume laboratories. However, more attention was still needed, or the results must be confirmed by other treponemal immunoassays. The new Elecsys® Syphilis assay is applied to patients with malignant neoplasm or HIV infection.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  immunoassay; sensitivity; specificity; syphilis

Mesh:

Substances:

Year:  2016        PMID: 27231125      PMCID: PMC6807250          DOI: 10.1002/jcla.21998

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  14 in total

1.  Characterization of Treponema pallidum particle agglutination assay-negative sera following screening by treponemal total antibody enzyme immunoassays.

Authors:  P A C Maple; D Ratcliffe; E Smit
Journal:  Clin Vaccine Immunol       Date:  2010-09-15

2.  Evaluation of LIAISON Treponema Screen, a novel recombinant antigen-based chemiluminescence immunoassay for laboratory diagnosis of syphilis.

Authors:  Antonella Marangoni; Vittorio Sambri; Silvia Accardo; Francesca Cavrini; Antonietta D'Antuono; Alessandra Moroni; Elisa Storni; Roberto Cevenini
Journal:  Clin Diagn Lab Immunol       Date:  2005-10

3.  Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis.

Authors:  Jingna An; Qixia Chen; Qianqian Liu; Chenli Rao; Dongdong Li; Tingting Wang; Chuanmin Tao; Lanlan Wang
Journal:  Clin Vaccine Immunol       Date:  2015-05-13

4.  Performance evaluation of the Elecsys syphilis assay for the detection of total antibodies to Treponema pallidum.

Authors:  Martin Enders; Andrea Hunjet; Michael Gleich; Roland Imdahl; Annelies Mühlbacher; Harald Schennach; Kriangsak Chaiwong; Tasanee Sakuldamrongpanich; Ajda Turhan; Rüchan Sertöz; Eva Wolf; Wolfgang Mayer; Chuanmin Tao; Lan Lan Wang; Simona Semprini; Vittorio Sambri
Journal:  Clin Vaccine Immunol       Date:  2014-10-29

5.  Vitros 5600 Syphilis TPA assay: evaluation of an automated chemiluminescence assay for detection of Treponema pallidum antibodies in a high prevalence setting.

Authors:  Dorien Van den Bossche; Eric Florence; Christopher Kenyon; Marjan Van Esbroeck
Journal:  Sex Transm Dis       Date:  2014-11       Impact factor: 2.830

Review 6.  Novel Treponema pallidum serologic tests: a paradigm shift in syphilis screening for the 21st century.

Authors:  Arlene C Seña; Becky L White; P Frederick Sparling
Journal:  Clin Infect Dis       Date:  2010-09-15       Impact factor: 9.079

7.  Evaluation of the LIAISON chemiluminescence immunoassay for diagnosis of syphilis.

Authors:  Carrie S Knight; Mary A Crum; Robert W Hardy
Journal:  Clin Vaccine Immunol       Date:  2007-04-25

8.  Syphilis detection using the Siemens ADVIA Centaur Syphilis treponemal assay.

Authors:  Ad Donkers; H Roma Levy; Annemiek Letens-van Vliet
Journal:  Clin Chim Acta       Date:  2014-02-08       Impact factor: 3.786

9.  Evaluation of the BioPlex 2200 syphilis system as a first-line method of reverse-sequence screening for syphilis diagnosis.

Authors:  Antonella Marangoni; Paola Nardini; Claudio Foschi; Alessandra Moroni; Antonietta D'Antuono; Letizia Bacchi Reggiani; Roberto Cevenini
Journal:  Clin Vaccine Immunol       Date:  2013-05-22

10.  Current standards for diagnosis and treatment of syphilis: selection of some practical issues, based on the European (IUSTI) and U.S. (CDC) guidelines.

Authors:  Maciej Pastuszczak; Anna Wojas-Pelc
Journal:  Postepy Dermatol Alergol       Date:  2013-08-27       Impact factor: 1.837

View more