Literature DB >> 25970652

Comparison of shear bond strength and bonding time of a novel flash-free bonding system.

Moonyoung Lee1, Georgios Kanavakis2.   

Abstract

OBJECTIVE: To evaluate the bonding time, shear bond strength (SBS), and adhesive residue index (ARI) of APC(TM) Flash-Free bonding system.
MATERIALS AND METHODS: Thirty-six extracted human maxillary premolars were randomly divided into three groups (12 per group) and used for this in vitro study: group 1, APC Flash-Free Adhesive Coated Appliance System; group 2, Clarity ADVANCED Ceramic Bracket pasted manually; group 3 (control group), 3M APC PLUS Adhesive prepasted brackets bonded with the extruded flash removed. Bonding time was measured using a stopwatch. Bond strength was measured using an Instron at a cross-head speed of 1 mm/min. The ARI was graded on a scale from 1 to 5. Repeated-measures analysis of variance and post hoc Tukey tests were used for statistical analysis.
RESULTS: It took significantly (P < .001) less time to bond in the APC Flash-Free Adhesive group (30.7 ± 3.3 seconds) compared with the control group (41.8 ± 4.0 seconds) and the manual group (39.2 ± 2.8 seconds). The APC Flash-Free Adhesive coated bracket had significantly (P < .001) greater SBS (13.7 ± 2.2 MPa) compared with the control group (10.8 ± 2.0 MPa) and the manual group (10.4 ± 1.4 MPa). The ARI was significantly (P < .001) greater with the APC Flash-Free Adhesive coated bracket compared with that of the other two groups.
CONCLUSIONS: Compared with other methods of bonding, the APC Flash-Free Adhesive Coated System can potentially reduce bonding time while increasing SBS.

Entities:  

Keywords:  Bonding systems; Bonding time; Flash free bonding; Shear bond strength

Mesh:

Year:  2015        PMID: 25970652     DOI: 10.2319/011715-37.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  10 in total

1.  Clinical performance of precoated brackets and self-etch bonding technique: a prospective comparative study.

Authors:  Ezgi Atik; Hande Gorucu-Coskuner; Tulin Taner
Journal:  Clin Oral Investig       Date:  2018-11-30       Impact factor: 3.573

2.  Shear Bond Strength of Ceramic Brackets with Different Base Designs: Comparative In-vitro Study.

Authors:  Mohd Younus Ansari; Deepak K Agarwal; Ankur Gupta; Preeti Bhattacharya; Juhi Ansar; Ravi Bhandari
Journal:  J Clin Diagn Res       Date:  2016-11-01

3.  A comparative assessment of bracket survival and adhesive removal time using flash-free or conventional adhesive for orthodontic bracket bonding: A split-mouth randomized controlled clinical trial.

Authors:  Thorsten Grünheid; Brent E Larson
Journal:  Angle Orthod       Date:  2018-09-19       Impact factor: 2.079

4.  Enamel around orthodontic brackets coated with flash-free and conventional adhesives.

Authors:  Mohamed Tarek ElSherifa; Marwa Sameh Shamaa; Mona A Montasser
Journal:  J Orofac Orthop       Date:  2020-07-21       Impact factor: 1.938

5.  Comparison of flash-free and conventional bonding systems: A systematic review and meta-analysis.

Authors:  He Wang; Ge Feng; Bo Hu; Haonan Tian; Yunchun Kuang; Tingwei Zhang; Jinlin Song
Journal:  Angle Orthod       Date:  2022-07-14       Impact factor: 2.684

6.  Effect of a single-component ceramic conditioner on shear bond strength of precoated brackets to different CAD/CAM materials.

Authors:  Carlos González-Serrano; Jin-Ho Phark; María Victoria Fuentes; Alberto Albaladejo; Andrés Sánchez-Monescillo; Sillas Duarte; Laura Ceballos
Journal:  Clin Oral Investig       Date:  2020-08-15       Impact factor: 3.573

7.  Effect of surface treatments and flash-free adhesive on the shear bond strength of ceramic orthodontic brackets to CAD/CAM provisional materials.

Authors:  Tarek Ahmed Soliman; Sayed Ghorab; Hossam Baeshen
Journal:  Clin Oral Investig       Date:  2021-10-04       Impact factor: 3.573

8.  Fluorescence-Aided Identification Technique (FIT) Improves Tooth Surface Clean-Up after Debonding of Buccal and Lingual Orthodontic Appliances.

Authors:  Olivia Engeler; Oliver Stadler; Simone Horn; Christian Dettwiler; Thomas Connert; Carlalberta Verna; Georgios Kanavakis
Journal:  J Clin Med       Date:  2021-12-31       Impact factor: 4.241

9.  The effect of beer and milk tea on the shear bond strength of adhesive precoated brackets: An in vitro comparative study.

Authors:  Weerada Vorachart; Nonglak Sombuntham; Kulthida Parakonthun
Journal:  Heliyon       Date:  2022-08-15

10.  Shear bond strength of a flash-free orthodontic adhesive system after thermal aging procedure.

Authors:  Carlos González-Serrano; Eugenia Baena; María-Victoria Fuentes; Alberto Albaladejo; Manuel Míguez-Contreras; Manuel O Lagravère; Laura Ceballos
Journal:  J Clin Exp Dent       Date:  2019-02-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.