Literature DB >> 25943608

Systematic review and meta-analysis of method comparison studies of Masimo pulse co-oximeters (Radical-7™ or Pronto-7™) and HemoCue® absorption spectrometers (B-Hemoglobin or 201+) with laboratory haemoglobin estimation.

R Hiscock1, D Kumar1, S W Simmons2.   

Abstract

We assessed agreement in haemoglobin measurement between Masimo pulse co-oximeters (Rad-7™ and Pronto-7™) and HemoCue® photometers (201+ or B-Hemoglobin) with laboratory-based determination and identified 39 relevant studies (2915 patients in Masimo group and 3084 patients in HemoCue group). In the Masimo group, the overall mean difference was -0.03 g/dl (95% prediction interval -0.30 to 0.23) and 95% limits of agreement -3.0 to 2.9 g/dl compared to 0.08 g/dl (95% prediction interval -0.04 to 0.20) and 95% limits of agreement -1.3 to 1.4 g/dl in the HemoCue group. Only B-Hemoglobin exhibited bias (0.53, 95% prediction interval 0.27 to 0.78). The overall standard deviation of difference was larger (1.42 g/dl versus 0.64 g/dl) for Masimo pulse co-oximeters compared to HemoCue photometers. Masimo devices and HemoCue 201+ both provide an unbiased, pooled estimate of laboratory haemoglobin. However, Masimo devices have lower precision and wider 95% limits of agreement than HemoCue devices. Clinicians should carefully consider these limits of agreement before basing transfusion or other clinical decisions on these point-of-care measurements alone.

Entities:  

Keywords:  haemoglobin; oximetry

Mesh:

Substances:

Year:  2015        PMID: 25943608     DOI: 10.1177/0310057X1504300310

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  18 in total

1.  mHealth spectroscopy of blood hemoglobin with spectral super-resolution.

Authors:  Sang Mok Park; Michelle A Visbal-Onufrak; Md Munirul Haque; Martin C Were; Violet Naanyu; Md Kamrul Hasan; Young L Kim
Journal:  Optica       Date:  2020-06-20       Impact factor: 11.104

2.  Detection of anaemia from retinal fundus images via deep learning.

Authors:  Yun Liu; Avinash V Varadarajan; Akinori Mitani; Abigail Huang; Subhashini Venugopalan; Greg S Corrado; Lily Peng; Dale R Webster; Naama Hammel
Journal:  Nat Biomed Eng       Date:  2019-12-23       Impact factor: 25.671

3.  Noninvasively Measured Hemoglobin Concentration Reflects Arterial Hemoglobin Concentration Before but Not After Cardiopulmonary Bypass in Patients Undergoing Coronary Artery or Valve Surgery.

Authors:  Matthias L Riess; Paul S Pagel
Journal:  J Cardiothorac Vasc Anesth       Date:  2016-03-24       Impact factor: 2.628

Review 4.  [Diagnostics and treatment of preoperative anemia].

Authors:  C Rosenthal; C von Heymann; L Kaufner
Journal:  Anaesthesist       Date:  2019-08       Impact factor: 1.041

5.  Poor Validity of Noninvasive Hemoglobin Measurements by Pulse Oximetry Compared with Conventional Absorptiometry in Children in Côte d'Ivoire.

Authors:  Isaac I Bogoch; Jean T Coulibaly; Jason Rajchgot; Jason R Andrews; Jana Kovac; Jürg Utzinger; Gordana Panic; Jennifer Keiser
Journal:  Am J Trop Med Hyg       Date:  2016-11-14       Impact factor: 2.345

Review 6.  Emerging point-of-care technologies for anemia detection.

Authors:  Ran An; Yuning Huang; Yuncheng Man; Russell W Valentine; Erdem Kucukal; Utku Goreke; Zoe Sekyonda; Connie Piccone; Amma Owusu-Ansah; Sanjay Ahuja; Jane A Little; Umut A Gurkan
Journal:  Lab Chip       Date:  2021-05-18       Impact factor: 6.799

7.  Validation of Masimo Pronto 7 and HemoCue 201 for hemoglobin determination in children from 1 to 5 years of age.

Authors:  Teresa Shamah Levy; Ignacio Méndez-Gómez-Humarán; María Del Carmen Morales Ruán; Brenda Martinez Tapia; Salvador Villalpando Hernández; Mauricio Hernández Ávila
Journal:  PLoS One       Date:  2017-02-07       Impact factor: 3.240

8.  Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India.

Authors:  Sutapa Bandyopadhyay Neogi; Jyoti Sharma; Shivam Pandey; Nausheen Zaidi; Maitreyee Bhattacharya; Rakhee Kar; Sitanshu Sekhar Kar; Abhishek Purohit; Sanjib Bandyopadhyay; Renu Saxena
Journal:  BMC Health Serv Res       Date:  2020-05-26       Impact factor: 2.655

9.  Cross-sectional relationship between haemoglobin concentration and measures of physical and cognitive function in an older rural South African population.

Authors:  Collin F Payne; Justine I Davies; F Xavier Gomez-Olive; Katherine J Hands; Kathleen Kahn; Lindsay C Kobayashi; Brent Tipping; Stephen M Tollman; Alisha Wade; Miles D Witham
Journal:  J Epidemiol Community Health       Date:  2018-04-21       Impact factor: 3.710

10.  Noninvasive hematocrit assessment for cardiovascular magnetic resonance extracellular volume quantification using a point-of-care device and synthetic derivation.

Authors:  Sean Robison; Gauri Rani Karur; Rachel M Wald; Paaladinesh Thavendiranathan; Andrew M Crean; Kate Hanneman
Journal:  J Cardiovasc Magn Reson       Date:  2018-03-15       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.