Literature DB >> 25934769

Effect of flow diversion with silk on aneurysm size: A single center experience.

Lee-Anne Slater1, Cathy Soufan2, Michael Holt1, Winston Chong3.   

Abstract

Alterations in aneurysm size and mass effect can result in alleviation or aggravation of symptoms. We assessed the effects of flow diversion with SILK stents on aneurysm sac size and associated factors. A retrospective evaluation of 14 aneurysms treated with SILK stents alone with MRI follow-up was performed. Aneurysm sac size was measured using the sequence best demonstrating the sac. Aneurysm characteristics and flow-related enhancement on time of flight images were documented. Clinical histories were reviewed for evolution of symptoms. Complete collapse of the aneurysm sac was demonstrated at three and 18 months in 2/14 aneurysms. Increase in size was observed in 2/14 aneurysms with associated persistent flow on time of flight MRA. Blister formation with aggravation of symptoms was observed in one aneurysm, and subsequent decrease in size occurred after treatment with a second SILK. The other aneurysm which increased in size initially continued to enlarge asymptomatically despite retreatment with a second SILK, however at 24 months thrombosis of the sac and decrease in size was observed. The remaining 10/14 aneurysms decreased in size. Nine had corresponding MRA occlusion and the tenth demonstrated decreased but persistent flow on the time of flight MRA. No aneurysm with MRA occlusion increased in size. Decrease in sac size was associated with MRA occlusion in our study. Persistence of flow and blistering were associated with increased sac size. As previously demonstrated flow diversion may be effective in the treatment of large aneurysms presenting with mass effect, however rates of sac obliteration in this small series were not as high as previously reported.
© The Author(s) 2015 Reprints and permissions:]br]sagepub.co.uk/journalsPermissions.nav.

Entities:  

Keywords:  Flow-diverter; Silk flow diversion device; aneurysm; intracranial; stents

Mesh:

Year:  2015        PMID: 25934769      PMCID: PMC4757208          DOI: 10.1177/1591019915576433

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  14 in total

1.  Delayed ipsilateral parenchymal hemorrhage following flow diversion for the treatment of anterior circulation aneurysms.

Authors:  J P Cruz; M Chow; C O'Kelly; B Marotta; J Spears; W Montanera; D Fiorella; T Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-08       Impact factor: 3.825

Review 2.  Flow diverter stents in the treatment of intracranial aneurysms: Where are we?

Authors:  Laurent Pierot
Journal:  J Neuroradiol       Date:  2011-01-22       Impact factor: 3.447

Review 3.  Flow diversion for intracranial aneurysms: a review.

Authors:  Pietro I D'Urso; Giuseppe Lanzino; Harry J Cloft; David F Kallmes
Journal:  Stroke       Date:  2011-07-07       Impact factor: 7.914

4.  Flow diverters for unruptured aneurysms: are they safe enough?

Authors:  Willem Jan van Rooij
Journal:  Neuroradiology       Date:  2012-07-22       Impact factor: 2.804

5.  High-profile flow diverter (silk) implantation in the basilar artery: efficacy in the treatment of aneurysms and the role of the perforators.

Authors:  Zsolt Kulcsár; Ulrike Ernemann; Stephan G Wetzel; Alexander Bock; Sophia Goericke; Vasilis Panagiotopoulos; Michael Forsting; Daniel A Ruefenacht; Isabel Wanke
Journal:  Stroke       Date:  2010-07-08       Impact factor: 7.914

6.  Volume changes of extremely large and giant intracranial aneurysms after treatment with flow diverter stents.

Authors:  Angelo Carneiro; Neil Rane; Wilhelm Küker; Martino Cellerini; Rufus Corkill; James V Byrne
Journal:  Neuroradiology       Date:  2013-12-07       Impact factor: 2.804

7.  Coiling of very large or giant cerebral aneurysms: long-term clinical and serial angiographic results.

Authors:  Menno Sluzewski; Tomas Menovsky; Willem Jan van Rooij; Douwe Wijnalda
Journal:  AJNR Am J Neuroradiol       Date:  2003-02       Impact factor: 3.825

Review 8.  Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis.

Authors:  Waleed Brinjikji; Mohammad H Murad; Giuseppe Lanzino; Harry J Cloft; David F Kallmes
Journal:  Stroke       Date:  2013-01-15       Impact factor: 7.914

9.  Comparison of flow diversion and coiling in large unruptured intracranial saccular aneurysms.

Authors:  Nohra Chalouhi; Stavropoula Tjoumakaris; Robert M Starke; L Fernando Gonzalez; Ciro Randazzo; David Hasan; Jeffrey F McMahon; Saurabh Singhal; Lea A Moukarzel; Aaron S Dumont; Robert Rosenwasser; Pascal Jabbour
Journal:  Stroke       Date:  2013-05-30       Impact factor: 7.914

10.  Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections.

Authors:  Sebastian Fischer; Zsolt Vajda; Marta Aguilar Perez; Elisabeth Schmid; Nikolai Hopf; Hansjörg Bäzner; Hans Henkes
Journal:  Neuroradiology       Date:  2011-09-01       Impact factor: 2.804

View more
  3 in total

1.  Outcome Study of the Pipeline Embolization Device with Shield Technology in Unruptured Aneurysms (PEDSU).

Authors:  D Atasoy; N Kandasamy; J Hart; J Lynch; S-H Yang; D Walsh; C Tolias; T C Booth
Journal:  AJNR Am J Neuroradiol       Date:  2019-11-14       Impact factor: 3.825

2.  Flow Diverter Stents for the Treatment of Anterior Cerebral Artery Aneurysms: Safety and Effectiveness.

Authors:  F Clarençon; F Di Maria; J Gabrieli; E Shotar; C Zeghal; A Nouet; J Chiras; N-A Sourour
Journal:  Clin Neuroradiol       Date:  2015-08-07       Impact factor: 3.649

3.  Flow Redirection Endoluminal Device (FRED) with or without Adjunctive Coiling in Treatment of Very Large and Giant Cerebral Aneurysms.

Authors:  Sedat Giray Kandemirli; Feyyaz Baltacioglu; Jessica Jesser; Osman Kizilkilic; Civan Islak; Markus Möhlenbruch; Naci Kocer
Journal:  Clin Neuroradiol       Date:  2021-07-26       Impact factor: 3.649

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.