Literature DB >> 25922453

The reliability and accuracy of measuring anteversion of the acetabular component on plain anteroposterior and lateral radiographs after total hip arthroplasty.

W C Shin1, S M Lee1, K W Lee1, H J Cho1, J S Lee1, K T Suh1.   

Abstract

There is no single standardised method of measuring the orientation of the acetabular component on plain radiographs after total hip arthroplasty. We assessed the reliability and accuracy of three methods of assessing anteversion of the acetabular component for 551 THAs using the PolyWare software and the methods of Liaw et al, and of Woo and Morrey. All measurements of the three methods had excellent intra- and inter-observer reliability. The values of the PolyWare software, which determines version of the acetabular component by edge detection were regarded as the reference standard. Although the PolyWare software and the method of Liaw et al were similarly precise, the method of Woo and Morrey was significantly less accurate (p < 0.001). The method of Liaw et al seemed to be more accurate than that of Woo and Morrey when compared with the measurements using the PolyWare software. If the qualified lateral radiograph was selected, anteversion measured using the method of Woo and Morrey was considered to be relatively reliable. ©2015 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  anteversion; plain radiograph; total hip arthroplasty

Mesh:

Year:  2015        PMID: 25922453     DOI: 10.1302/0301-620X.97B5.34735

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  12 in total

1.  Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

Authors:  T Schwarz; M Weber; M Wörner; T Renkawitz; J Grifka; B Craiovan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-10-06       Impact factor: 2.924

2.  Analysis of acetabular orientation and femoral anteversion using images of three-dimensional reconstructed bone models.

Authors:  Jaeyeong Park; Jun-Young Kim; Hyun Deok Kim; Young Cheol Kim; Anna Seo; Minkyu Je; Jong Uk Mun; Bia Kim; Il Hyung Park; Shin-Yoon Kim
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-01-06       Impact factor: 2.924

Review 3.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

4.  Comparison of clinical results and patient's satisfaction between direct anterior approach and Hardinge approach in primary total hip arthroplasty in a community hospital.

Authors:  C Trevisan; R Compagnoni; R Klumpp
Journal:  Musculoskelet Surg       Date:  2017-04-27

5.  Level of surgical experience is associated with change in hip center of rotation following cementless total hip arthroplasty: A radiographic assessment.

Authors:  Seung-Chan Kim; Young-Wook Lim; Soon-Yong Kwon; Woo-Lam Jo; Sung-Hun Ju; Chan-Joo Park; Choong-Woo Lee; Yong-Sik Kim
Journal:  PLoS One       Date:  2017-05-24       Impact factor: 3.240

6.  Surgical accuracy, function, and quality of life of simultaneous versus staged bilateral Total hip Arthroplasty in patients with Osteonecrosis of the femoral head.

Authors:  Seung-Chan Kim; Young-Wook Lim; Woo-Lam Jo; Dong-Chul Park; Jin-Woo Lee; Won-Woo Kang; Yong-Sik Kim
Journal:  BMC Musculoskelet Disord       Date:  2017-06-17       Impact factor: 2.362

7.  Accuracy of planar anteversion measurements using anteroposterior radiographs.

Authors:  Gwang Chul Lee; Sang Hong Lee; Sin Wook Kang; Hyung Seok Park; Suenghwan Jo
Journal:  BMC Musculoskelet Disord       Date:  2019-12-05       Impact factor: 2.362

8.  Robot-Assisted Total Hip Arthroplasty for Arthrodesed Hips.

Authors:  Wei Chai; Xiangpeng Kong; Minzhi Yang; Ken Lee Puah; Peifu Tang; Jiying Chen
Journal:  Ther Clin Risk Manag       Date:  2020-05-04       Impact factor: 2.423

9.  The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs.

Authors:  Yang Soo Park; Won Chul Shin; Sang Min Lee; Sang Ho Kwak; Jung Yun Bae; Kuen Tak Suh
Journal:  J Orthop Surg Res       Date:  2018-04-02       Impact factor: 2.359

10.  Evaluation of Tilt-correction of Anteversion on Anteroposterior Pelvic Radiographs in Total Hip Arthroplasty.

Authors:  Jeffrey M Muir; John Vincent; Joseph Schipper; Meinusha Govindarajan; Wayne G Paprosky
Journal:  Cureus       Date:  2018-05-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.