PURPOSE: The aim of this study was to provide fundus-controlled two-color adaptometry with an existing device. A quick and easy approach extends the application possibilities of a commercial fundus-controlled perimeter.
METHODS: An external filter holder was placed in front the objective lens of the MP1 (Nidek, Italy) and fitted with filters to modify background, stimulus intensity, and color. Prior to dark adaptometry, the subject's visual sensitivity profile was measured for red and blue stimuli to determine whether rods or cones or both mediated the absolute threshold. After light adaptation, 20 healthy subjects were investigated with a pattern covering six spots at the posterior pole of the retina up to 45 min of dark adaptation. Thresholds were determined using a 200 ms red Goldmann IV and a blue Goldmann II stimulus.
RESULTS: The pre-test sensitivity showed a typical distribution of values along the meridian, with high peripheral light increment sensitivity (LIS) and low central LIS for rods and the reverse for cones. After bleach, threshold recovery had a classic biphasic shape. The absolute threshold was reached after approximately 10 min for the red and 15 min for the blue stimulus.
CONCLUSIONS: Two-color fundus-controlled adaptometry with a commercial MP1 without internal changes to the device provides a quick and easy examination of rod and cone function during dark adaptation at defined retinal loci of the posterior pole. This innovative method will be helpful to measure rod vs. cone function at known loci of the posterior pole in early stages of retinal degenerations.

Entities:  

Mesh:

Year:  2015        PMID: 25904295     DOI: 10.1007/s00417-015-3010-6

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  26 in total

Review 1.  Into the twilight zone: the complexities of mesopic vision and luminous efficiency.

Authors:  Andrew Stockman; Lindsay T Sharpe
Journal:  Ophthalmic Physiol Opt       Date:  2006-05       Impact factor: 3.117

2.  Retinal function and rhodopsin levels in autosomal dominant retinitis pigmentosa with rhodopsin mutations.

Authors:  S G Jacobson; C M Kemp; C H Sung; J Nathans
Journal:  Am J Ophthalmol       Date:  1991-09-15       Impact factor: 5.258

3.  Rod sensitivity, cone sensitivity, and photoreceptor layer thickness in retinal degenerative diseases.

Authors:  David G Birch; Yuquan Wen; Kelly Locke; Donald C Hood
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-09-09       Impact factor: 4.799

4.  Effects of target size and eccentricity on visual detection and resolution.

Authors:  C A Johnson; J L Keltner; F Balestrery
Journal:  Vision Res       Date:  1978       Impact factor: 1.886

5.  Rod sensitivity relative to cone sensitivity in retinitis pigmentosa.

Authors:  R W Massof; D Finkelstein
Journal:  Invest Ophthalmol Vis Sci       Date:  1979-03       Impact factor: 4.799

6.  Static and acuity profile perimetry at various adaptation levels.

Authors:  C A Johnson; J L Keltner; F G Balestrery
Journal:  Doc Ophthalmol       Date:  1981-03-20       Impact factor: 2.379

7.  Disease expression of RP1 mutations causing autosomal dominant retinitis pigmentosa.

Authors:  S G Jacobson; A V Cideciyan; A Iannaccone; R G Weleber; G A Fishman; A M Maguire; L M Affatigato; J Bennett; E A Pierce; M Danciger; D B Farber; E M Stone
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-06       Impact factor: 4.799

8.  Reliability and consistency of dark-adapted psychophysical measures in advanced eye disease.

Authors:  Ava K Kiser; Derek Mladenovich; Fariba Eshraghi; Debra Bourdeau; Gislin Dagnelie
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-01       Impact factor: 4.799

9.  Peripheral absolute threshold spectral sensitivity in retinitis pigmentosa.

Authors:  R W Massof; M A Johnson; D Finkelstein
Journal:  Br J Ophthalmol       Date:  1981-02       Impact factor: 4.638

10.  Improving detection of mild loss of retinal light increment sensitivity at the posterior pole with the microperimeter MP1.

Authors:  Wadim Bowl; Birgit Lorenz; Melanie Jäger; Christoph Friedburg
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-07-12       Impact factor: 4.799

View more
  2 in total

1.  Measurement of dark adaptometry during ISCEV standard flash electroretinography.

Authors:  Jeff Rabin; Brooke Houser; Carolyn Talbert; Rue Patel
Journal:  Doc Ophthalmol       Date:  2017-10-03       Impact factor: 2.379

2.  Fundus-Controlled Dark Adaptometry in Young Children Without and With Spontaneously Regressed Retinopathy of Prematurity.

Authors:  Wadim Bowl; Birgit Lorenz; Knut Stieger; Silke Schweinfurth; Kerstin Holve; Monika Andrassi-Darida
Journal:  Transl Vis Sci Technol       Date:  2019-06-28       Impact factor: 3.283

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.