Literature DB >> 25892745

A FIELD CANCELATION SIGNAL EXTRACTION METHOD FOR MAGNETIC PARTICLE IMAGING.

Volkmar Schulz1,2, Marcel Straub1, Max Mahlke2, Simon Hubertus1, Twan Lammers3, Fabian Kiessling3.   

Abstract

In nowadays Magnetic Particle Imaging (MPI) signal detection and excitation happens at the same time. This concept, however, leads to strong coupling of the drive (excitation) field (DF) with the receive chain. As the induced DF signal is several orders of magnitude higher, special measures have to be taken to suppress this signal portion within the receive signal to keep the required dynamic range of the subsequent analog to digital conversion in a technically feasible range. For "frequency space MPI" high-order band-stop-filters have been successfully used to remove the DF signals, which unfortunately as well removes the fundamental harmonic components of the signal of the magnetic nanoparticles (MNP). According to the Langevin theory the fundamental harmonic component has a large signal contribution and is important for direct reconstruction of the particle concentration. In order to separate the fundamental harmonic component of the MNP from the induced DF signal, different concepts have been proposed using signal cancelation based on additional DF signals, also in combination with additional filtering. In this paper, we propose a field-cancelation (FC) concept in which a receive coil (RC) consists of a series connection of a primary coil in combination with an additional cancelation coil. The geometry of the primary coil was chosen to be sensitive for the MNP signal while the cancelation coil was chosen to minimize the overall inductive coupling of the FC-RC with the DF. Sensitivity plots and mutual coupling coefficients were calculated using a thin-wire approximation. A prototype FC-RC was manufactured and effectiveness of the reduction of the mutual inductive coupling (d) was tested in an existing mouse MPI scanner. The difference between simulations (ds =70 dB) and the measurements (dms =55 dB) indicated the feasibility as well as the need for further investigations.

Entities:  

Keywords:  MPI; Magnetic Particle Imaging; field cancelation; receive coil

Year:  2015        PMID: 25892745      PMCID: PMC4398986          DOI: 10.1109/TMAG.2014.2325852

Source DB:  PubMed          Journal:  IEEE Trans Magn        ISSN: 0018-9464            Impact factor:   1.700


  8 in total

1.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

2.  Tomographic imaging using the nonlinear response of magnetic particles.

Authors:  Bernhard Gleich; Jürgen Weizenecker
Journal:  Nature       Date:  2005-06-30       Impact factor: 49.962

3.  Three-dimensional real-time in vivo magnetic particle imaging.

Authors:  J Weizenecker; B Gleich; J Rahmer; H Dahnke; J Borgert
Journal:  Phys Med Biol       Date:  2009-02-10       Impact factor: 3.609

4.  Analog receive signal processing for magnetic particle imaging.

Authors:  Matthias Graeser; Tobias Knopp; Mandy Grüttner; Timo F Sattel; Thorsten M Buzug
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

5.  The X-space formulation of the magnetic particle imaging process: 1-D signal, resolution, bandwidth, SNR, SAR, and magnetostimulation.

Authors:  Patrick W Goodwill; Steven M Conolly
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

6.  Projection x-space magnetic particle imaging.

Authors:  Patrick W Goodwill; Justin J Konkle; Bo Zheng; Emine U Saritas; Steven M Conolly
Journal:  IEEE Trans Med Imaging       Date:  2012-05       Impact factor: 10.048

7.  Flexible and modular MPI simulation framework and its use in modelling a μMPI.

Authors:  Marcel Straub; Twan Lammers; Fabian Kiessling; Volkmar Schulz
Journal:  IEEE Trans Magn       Date:  2015-02-01       Impact factor: 1.700

8.  Signal encoding in magnetic particle imaging: properties of the system function.

Authors:  Jürgen Rahmer; Jürgen Weizenecker; Bernhard Gleich; Jörn Borgert
Journal:  BMC Med Imaging       Date:  2009-04-01       Impact factor: 1.930

  8 in total
  2 in total

1.  Flexible and modular MPI simulation framework and its use in modelling a μMPI.

Authors:  Marcel Straub; Twan Lammers; Fabian Kiessling; Volkmar Schulz
Journal:  IEEE Trans Magn       Date:  2015-02-01       Impact factor: 1.700

2.  Real-Time Two-Dimensional Magnetic Particle Imaging for Electromagnetic Navigation in Targeted Drug Delivery.

Authors:  Tuan-Anh Le; Xingming Zhang; Ali Kafash Hoshiar; Jungwon Yoon
Journal:  Sensors (Basel)       Date:  2017-09-07       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.