Literature DB >> 20529726

The X-space formulation of the magnetic particle imaging process: 1-D signal, resolution, bandwidth, SNR, SAR, and magnetostimulation.

Patrick W Goodwill1, Steven M Conolly.   

Abstract

The magnetic particle imaging (MPI) imaging process is a new method of medical imaging with great promise. In this paper we derive the 1-D MPI signal, resolution, bandwidth requirements, signal-to-noise ratio (SNR), specific absorption rate, and slew rate limitations. We conclude with experimental data measuring the point spread function for commercially available SPIO nanoparticles and a demonstration of the principles behind 1-D imaging using a static offset field. Despite arising from the nonlinear temporal response of a magnetic nanoparticle to a changing magnetic field, the imaging process is linear in the magnetization distribution and can be described as a convolution. Reconstruction in one dimension is exact and has a well-behaved quasi-Lorentzian point spread function.The spatial resolution improves cubically with increasing diameter of the SPIO domain, inverse to absolute temperature, linearly with saturation magnetization, and inversely with gradient. The band width requirements approach a megahertz for reasonable imaging parameters and millimeter scale resolutions, and the SNR increases with the scanning rate. The limit to SNR as we scale MPI to human sizes will be patient heating. SAR and magnetostimulation limits give us surprising relations between optimal scanning speeds and scanning frequency for different types of scanners.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20529726     DOI: 10.1109/TMI.2010.2052284

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  76 in total

1.  Tracer design for magnetic particle imaging (invited).

Authors:  R Matthew Ferguson; Amit P Khandhar; Kannan M Krishnan
Journal:  J Appl Phys       Date:  2012-03-02       Impact factor: 2.546

2.  The use of magnetic nanoparticles in thermal therapy monitoring and screening: Localization and imaging (invited).

Authors:  John B Weaver
Journal:  J Appl Phys       Date:  2012-03-02       Impact factor: 2.546

3.  An x-space magnetic particle imaging scanner.

Authors:  Patrick W Goodwill; Kuan Lu; Bo Zheng; Steven M Conolly
Journal:  Rev Sci Instrum       Date:  2012-03       Impact factor: 1.523

4.  Ferrohydrodynamic modeling of magnetic nanoparticle harmonic spectra for magnetic particle imaging.

Authors:  Rohan Dhavalikar; Lorena Maldonado-Camargo; Nicolas Garraud; Carlos Rinaldi
Journal:  J Appl Phys       Date:  2015-11-05       Impact factor: 2.546

5.  Low drive field amplitude for improved image resolution in magnetic particle imaging.

Authors:  Laura R Croft; Patrick W Goodwill; Justin J Konkle; Hamed Arami; Daniel A Price; Ada X Li; Emine U Saritas; Steven M Conolly
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

6.  Rodent Cerebral Blood Volume (CBV) changes during hypercapnia observed using Magnetic Particle Imaging (MPI) detection.

Authors:  Clarissa Zimmerman Cooley; Joseph B Mandeville; Erica E Mason; Emiri T Mandeville; Lawrence L Wald
Journal:  Neuroimage       Date:  2018-05-05       Impact factor: 6.556

7.  Size-dependent ferrohydrodynamic relaxometry of magnetic particle imaging tracers in different environments.

Authors:  Hamed Arami; R M Ferguson; Amit P Khandhar; Kannan M Krishnan
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

8.  Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging.

Authors:  R Matthew Ferguson; Kevin R Minard; Amit P Khandhar; Kannan M Krishnan
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

9.  Effects of pulse duration on magnetostimulation thresholds.

Authors:  Emine U Saritas; Patrick W Goodwill; Steven M Conolly
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

Review 10.  Magnetic particle imaging for radiation-free, sensitive and high-contrast vascular imaging and cell tracking.

Authors:  Xinyi Y Zhou; Zhi Wei Tay; Prashant Chandrasekharan; Elaine Y Yu; Daniel W Hensley; Ryan Orendorff; Kenneth E Jeffris; David Mai; Bo Zheng; Patrick W Goodwill; Steven M Conolly
Journal:  Curr Opin Chem Biol       Date:  2018-05-10       Impact factor: 8.822

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.