Lina De Geer1, Anna Oscarsson2, Jan Engvall3.
Abstract
BACKGROUND: Echocardiography is increasingly used for haemodynamic evaluation and titration of therapy in intensive care, warranting reliable and reproducible measurements. The aim of this study was to evaluate the observer dependence of echocardiographic findings of left ventricular (LV) diastolic and systolic dysfunction in patients with septic shock.Entities:
Mesh:
Year: 2015 PMID: 25880324 PMCID: PMC4399417 DOI: 10.1186/s12947-015-0015-6
Source DB: PubMed Journal: Cardiovasc Ultrasound ISSN: 1476-7120 Impact factor: 2.062
Baseline and echocardiographic characteristics of studied patients
| Number of pts, n | 47 |
| Male sex, n (%) | 29 (62) |
| Age, median (IQR) | 65 (57 – 74) |
| SAPS 3, median (IQR) | 73 (45 – 84) |
| EMR, median (IQR) | 60 (38 – 76) |
| SOFA day 1, median (IQR) | 11 (9 – 12) |
| ICU LOS, days, median (IQR) | 5 (2 – 12) |
| Mechanical ventilation at time of echocardiography, n (%) | 35 (74) |
| Heart rate at time of echocardiography, median (IQR) | 102 (87 – 112) |
| Atrial fibrillation at time of echocardiography, n (%) | 13 (28) |
| Pre-existing cardiac disease, n (%) | 23 (49) |
| Death in ICU, n (%) | 10 (21) |
| Death within 30 days, n (%) | 12 (26) |
| Death within 90 days, n (%) | 14 (30) |
Data are presented as medians (IQR) and numbers (%), as appropriate.
Left ventricular function on day 1
|
|
| |
|---|---|---|
| é cm/s | 8.1 ± 3.0 (1.7 – 19.0) | 9.0 ± 4.0 (2.9 – 22.0) |
| E/é | 14.4 ± 11.7 (5.0 – 68.1) | 11.4 ± 8.9 (1.0 – 52.3) |
| EF, % | 49 ± 11 (17 – 76) | 50 ± 12 (22 – 75) |
| GLPS, % | −16.6 ± 4.4 (−26.7 – (−3.1)) | −16.6 ± 4.6 (−24.5 – (−3.9)) |
Means ± standard deviation (range) for diastolic and systolic function parameters measured by the two observers.
Figure 1The correlation between and Bland-Altman analysis of é and E/é measured by two observers. Pearson’s correlation coefficient, mean measurements, differences and 95% limits of agreement (1.96 SD) between measurements by two observers.
Repeatability of results
|
|
|
|
| |||||
|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
| |
| Interobserver | 0.85 (0.73 – 0.92) | <0.001 | 0.70 (0.45 – 0.84) | <0.001 | 0.87 (0.77 – 0.93) | <0.001 | 0.91 (0.74 - 0.95) | <0.001 |
| Intraobserver | 0.91 (0.58 – 0.98) | 0.002 | 0.95 (0.80 – 0.99) | <0.001 | 0.84 (0.75 – 0.90) | <0.001 | 0.89 (0.55-0.97) | 0.002 |
Intraclass correlation coefficients (95% CI) and level of significance for the inter- and intraobserver variability of diastolic and systolic LV parameters.
Figure 2The correlation between and Bland-Altman analysis of EF and GLPS measured by two observers. Pearson’s correlation coefficient, mean measurements, differences and 95% limits of agreement (1.96 SD) between measurements by two observers.
Figure 3Variability of GLPS measurements. Segmental strain and GLPS of the left ventricle illustrated using automatic function imaging from three apical views and averaged for 18 segments; A. Measurements performed by observer 1, GLPS −17.9%; B. Measurements performed by observer 2, GLPS −20.0%; and C. Measurements re-assessed by observer 2, GLPS −18.4%.