Literature DB >> 2586373

A correlated noise reduction algorithm for dual-energy digital subtraction angiography.

C H McCollough1, M S Van Lysel, W W Peppler, C A Mistretta.   

Abstract

It has long been recognized that the problems of motion artifacts in conventional time subtraction digital subtraction angiography (DSA) may be overcome using energy subtraction techniques. Of the variety of energy subtraction techniques investigated, non-k-edge dual-energy subtraction offers the best signal-to-noise ratio (SNR). However, this technique achieves only 55% of the temporal DSA SNR. Noise reduction techniques that average the noisier high-energy image produce various degrees of noise improvement while minimally affecting iodine contrast and resolution. A more significant improvement in dual-energy DSA iodine SNR, however, results when the correlated noise that exists in material specific images is appropriately cancelled. The correlated noise reduction (CNR) algorithm presented here follows directly from the dual-energy computed tomography work of Kalender who made explicit use of noise correlations in material specific images to reduce noise. The results are identical to those achieved using a linear version of the two-stage filtering process described by Macovski in which the selective image is filtered to reduce high-frequency noise and added to a weighted, high SNR, nonselective image which has been processed with a high-frequency bandpass filter. The dual-energy DSA CNR algorithm presented here combines selective tissue and iodine images to produce a significant increase in the iodine SNR while fully preserving iodine spatial resolution. Theoretical calculations predict a factor of 2-4 improvement in SNR compared to conventional dual-energy images. The improvement factor achieved is dependent upon the x-ray beam spectra and the size of blurring kernel used in the algorithm.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2586373     DOI: 10.1118/1.596436

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Dual-energy contrast-enhanced digital breast tomosynthesis--a feasibility study.

Authors:  A-K Carton; S C Gavenonis; J A Currivan; E F Conant; M D Schnall; A D A Maidment
Journal:  Br J Radiol       Date:  2009-06-08       Impact factor: 3.039

2.  Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images.

Authors:  Samuel Richard; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

3.  Dual-energy digital mammography for calcification imaging: noise reduction techniques.

Authors:  S Cheenu Kappadath; Chris C Shaw
Journal:  Phys Med Biol       Date:  2008-09-02       Impact factor: 3.609

4.  Left ventricular dual-energy digital subtraction angiography: a motion immune digital subtraction technique.

Authors:  M S Van Lysel; W P Miller; D G Senior; V K Gupta; D J Ende; D J Albright
Journal:  Int J Card Imaging       Date:  1991

Review 5.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Joel G Fletcher
Journal:  Radiology       Date:  2015-09       Impact factor: 11.105

6.  Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study.

Authors:  Bitbyeol Kim; Ho Kyung Kim; Jinsung Kim; Yongkan Ki; Ji Hyeon Joo; Hosang Jeon; Dahl Park; Wontaek Kim; Jiho Nam; Dong Hyeon Kim
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2021-09-15

7.  Simultaneous reduction in noise and cross-contamination artifacts for dual-energy X-ray CT.

Authors:  Baojun Li; Baohong Li; Jack Luo; Peng Tang; Jiandong Mao; Xiaoye Wu
Journal:  Biomed Res Int       Date:  2013-06-19       Impact factor: 3.411

Review 8.  The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence.

Authors:  Martin J Willemink; Peter B Noël
Journal:  Eur Radiol       Date:  2018-10-30       Impact factor: 5.315

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.