Abstract
PURPOSE: The purpose of this study is to compare dosimetric parameters of intensity-modulated mode of TomoDirect and three-dimensional conformal radiotherapy (3D-CRT) in patients with early breast cancer.Entities:
Keywords: Breast; Neoplasms; Radiometry; Radiotherapy
Year: 2015 PMID: 25834612 PMCID: PMC4381124 DOI: 10.4048/jbc.2015.18.1.57
Source DB: PubMed Journal: J Breast Cancer ISSN: 1738-6756 Impact factor: 3.588
Figure 1Dose distribution for TomoDirect plan (A) and three-dimensional conformal radiotherapy plan (B). Red contour means the planning target volume which contains lumpectomy site with clips and normal breast tissue.
Patient characteristics (n=26)
| Characteristic | No. (%) |
|---|---|
| Age (yr)* | 51 (37-70) |
| Body mass index (kg/m2)* | 23 (19-29) |
| Site | |
| Right | 11 (42.3) |
| Left | 15 (57.7) |
| pT stage | |
| Tis | 12 (46.2) |
| T1 | 10 (38.4) |
| T2 | 4 (15.4) |
| Tumor location | |
| Upper | 24 (92.3) |
| Lower | 2 (7.7) |
| Axillary staging | |
| None | 9 (34.7 ) |
| Sentinal node biopsy | 3 (11.5) |
| Axillary node dissection | 14 (53.8) |
| Presence of seroma ≥ 15 mL | |
| Negative | 20 (77.0) |
| Positive | 6 (23.0) |
| Adjuvant chemotherapy | |
| No | 13 (50.0) |
| Yes | 13 (50.0) |
*Median (range).
Comparison of dosimetric parameters for the planning target volume between TomoDirect and three-dimensional conformal radiotherapy
| Parameter | TomoDirect | 3D-CRT | |
|---|---|---|---|
| Mean dose (Gy) | 51.65 ± 0.37 | 50.88 ± 0.65 | <0.001 |
| V47.8 (%) | 100 ± 0.00 | 89.23 ± 6.33 | <0.001 |
| V52.9 (%) | 5.23 ± 10.02 | 4.46 ± 4.94 | 0.727 |
| V55.4 (%) | 0.13 ± 0.52 | 0.00 ± 0.00 | 0.193 |
| Dmin (Gy) | 39.96 ± 5.96 | 36.61 ± 2.37 | 0.011 |
| Dmax (Gy) | 55.40 ± 1.45 | 54.26 ± 0.92 | 0.001 |
| RCI | 1 ± 0.00 | 1.13 ± 0.10 | <0.001 |
| rDHI | 0.72 ± 0.11 | 0.67 ± 0.04 | 0.056 |
3D-CRT=three-dimensional conformal radiotherapy; VnGy=percentage of the volume receiving radiation ≥n Gy; Dmin=minimum dose irradiated to the planning target volume; Dmax=maximum dose irradiated to the planning target volume; RCI=radiation conformality index; rDHI=radical dose homogeneity index.
Figure 2Dose-volume histogram of the planning target volume in TomoDirect and three-dimensional conformal radiotherapy (3D-CRT) planning. The mean value of V47.8 was significantly higher in TomoDirect than in 3D-CRT (100% vs. 89.2%, *p<0.001).
VnGy=percentage of the volume receiving radiation ≥n Gy.
Comparison of dosimetric parameters for the ipsilateral lung and heart between TomoDirect and three-dimensional conformal radiotherapy
| Parameter | TomoDirect | 3D-CRT | ||
|---|---|---|---|---|
| Lung | Mean (Gy) | 5.07 ± 1.81 | 6.94 ± 2.25 | 0.002 |
| V40 (%) | 4.73 ± 2.86 | 9.71 ± 4.12 | <0.001 | |
| V30 (%) | 6.83 ± 3.51 | 11.5 ± 4.42 | <0.001 | |
| V20 (%) | 8.98 ± 4.01 | 13.19 ± 4.70 | 0.001 | |
| V10 (%) | 12.32 ± 4.28 | 15.28 ± 4.99 | 0.026 | |
| Heart | Mean (Gy) | 1.05 ± 0.82 | 1.62 ± 1.44 | 0.085 |
| V40 (%) | 0.24 ± 0.80 | 0.53 ± 1.53 | 0.395 | |
| V30 (%) | 0.47 ± 1.17 | 0.96 ± 1.98 | 0.290 | |
| V20 (%) | 0.73 ± 1.48 | 1.53 ± 2.53 | 0.169 | |
| V10 (%) | 1.16 ± 2.02 | 2.19 ± 3.26 | 0.780 | |
| Coronary artery* | Mean (Gy) | 7.24 ± 2.11 | 12.13 ± 2.84 | <0.001 |
3D-CRT=three-dimensional conformal radiotherapy; VnGy=percentage of the volume receiving radiation ≥n Gy.
*Irradiated doses of left anterior descending coronary artery were compared in left breast cancer patients.
Figure 3Dose volume histogram of the ipsilateral lung (A) and heart (B) in TomoDirect and three-dimensional conformal radiotherapy (3D-CRT) planning. The mean±SD values of V10, V20, V30, and V40 of ipsilateral lung were significantly lower in TomoDirect than in 3D-CRT.
VnGy=percentage of the volume receiving radiation ≥n Gy.
*p<0.05.