Literature DB >> 24393498

A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes.

Andrea Michalski1, John Atyeo2, Jennifer Cox3, Marianne Rinks4, Marita Morgia5, Gillian Lamoury5.   

Abstract

Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. All patients were prescribed a dose of 45Gy in 20 fractions to the breast with an SIB of 56Gy in 20 fractions to the tumor bed and normalized so that D98% > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D98% > 95% and D2% < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTVboost eval (0.079 ± 0.011) and breast minus the SIB volume (BreastSIB) (p < 0.001, 0.15 ± 0.03) compared with the PTVboost eval (0.085 ± 0.008, 0.088 ± 0.12) and BreastSIB (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11Gy compared with 7.75 ± 2.54Gy and 8.29 ± 2.76Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44Gy and 3.91 ± 1.58Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D-CRT in both PTV dose conformity and reduction of mean doses to the ipsilateral lung. Crown
Copyright © 2014. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3D-CRT; Breast cancer; IMRT; Simultaneous integrated boost; Tomotherapy

Mesh:

Year:  2014        PMID: 24393498     DOI: 10.1016/j.meddos.2013.12.003

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  17 in total

1.  Comparing four radiotherapy techniques for treating the chest wall plus levels III-IV draining nodes after breast reconstruction.

Authors:  Valentina Lancellotta; Martina Iacco; Elisabetta Perrucci; Lorenzo Falcinelli; Claudio Zucchetti; Berardino de Bari; Simonetta Saldi; Cynthia Aristei
Journal:  Br J Radiol       Date:  2018-03-19       Impact factor: 3.039

2.  Dosimetric Comparison of Sequential Versus Simultaneous-integrated Boost in Early-stage Breast Cancer Patients Treated With Breast-conserving Surgery.

Authors:  Cem Onal; Esma Efe; Ozan C Guler; Berna A Yildirim
Journal:  In Vivo       Date:  2019 Nov-Dec       Impact factor: 2.155

3.  Developing Multivariable Normal Tissue Complication Probability Model to Predict the Incidence of Symptomatic Radiation Pneumonitis among Breast Cancer Patients.

Authors:  Tsair-Fwu Lee; Pei-Ju Chao; Liyun Chang; Hui-Min Ting; Yu-Jie Huang
Journal:  PLoS One       Date:  2015-07-06       Impact factor: 3.240

4.  A Dosimetric Comparative Analysis of TomoDirect and Three-Dimensional Conformal Radiotherapy in Early Breast Cancer.

Authors:  Mi Joo Chung; Sung Hwan Kim; Jong Hoon Lee; Young Jin Suh
Journal:  J Breast Cancer       Date:  2015-03-27       Impact factor: 3.588

5.  Dosimetric comparison of three intensity-modulated radiation therapies for left breast cancer after breast-conserving surgery.

Authors:  Huai-Wen Zhang; Bo Hu; Chen Xie; Yun-Lai Wang
Journal:  J Appl Clin Med Phys       Date:  2018-03-10       Impact factor: 2.102

6.  Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index.

Authors:  Jackie Yim; Clare Suttie; Regina Bromley; Marita Morgia; Gillian Lamoury
Journal:  J Med Radiat Sci       Date:  2015-08-20

7.  Simultaneous integrated boost (SIB) radiation therapy of right sided breast cancer with and without flattening filter - A treatment planning study.

Authors:  Johannes Maier; Bernadette Knott; Manuel Maerz; Rainer Loeschel; Oliver Koelbl; Barbara Dobler
Journal:  Radiat Oncol       Date:  2016-08-31       Impact factor: 3.481

8.  The feasibility of a heart block with an electron compensation as an alternative whole breast radiotherapy technique in patients with underlying cardiac or pulmonary disease.

Authors:  Hye Jin Kang; Shin-Wook Kim; Seok Hyun Son
Journal:  PLoS One       Date:  2017-09-01       Impact factor: 3.240

9.  Evaluation of the anatomical parameters for normal tissue sparing in the prone position radiotherapy with small sized left breasts.

Authors:  Hyunjung Kim; Jinyoung Kim
Journal:  Oncotarget       Date:  2016-11-01

10.  Analysis of Geometric and Dosimetric Effects of Bra Application to Support Large or Pendulous Breasts During Radiotherapy Planning: A Retrospective Single-Center Study.

Authors:  So Hyun Park; Jinhyun Choi
Journal:  Technol Cancer Res Treat       Date:  2021 Jan-Dec
View more