Literature DB >> 24480375

Dosimetric comparison of 3D conformal, IMRT, and V-MAT techniques for accelerated partial-breast irradiation (APBI).

Jian-Jian Qiu1, Zheng Chang2, Janet K Horton2, Qing-Rong Jackie Wu2, Sua Yoo2, Fang-Fang Yin3.   

Abstract

The purpose is to dosimetrically compare the following 3 delivery techniques: 3-dimensional conformal radiation therapy (3D-CRT), intensity-modulated arc therapy (IMRT), and volumetric-modulated arc therapy (V-MAT) in the treatment of accelerated partial-breast irradiation (APBI). Overall, 16 patients with T1/2N0 breast cancer were treated with 3D-CRT (multiple, noncoplanar photon fields) on the RTOG 0413 partial-breast trial. These cases were subsequently replanned using static gantry IMRT and V-MAT technology to understand dosimetric differences among these 3 techniques. Several dosimetric parameters were used in plan quality evaluation, including dose conformity index (CI) and dose-volume histogram analysis of normal tissue coverage. Quality assurance studies including gamma analysis were performed to compare the measured and calculated dose distributions. The IMRT and V-MAT plans gave more conformal target dose distributions than the 3D-CRT plans (p < 0.05 in CI). The volume of ipsilateral breast receiving 5 and 10Gy was significantly less using the V-MAT technique than with either 3D-CRT or IMRT (p < 0.05). The maximum lung dose and the ipsilateral lung volume receiving 10 (V10) or 20Gy (V20) were significantly less with both V-MAT and IMRT (p < 0.05). The IMRT technique was superior to 3D-CRT and V-MAT of low dose distributions in ipsilateral lung (p < 0.05 in V5 and D5). The total mean monitor units (MUs) for V-MAT (621.0 ± 111.9) were 12.2% less than those for 3D-CRT (707.3 ± 130.9) and 46.5% less than those for IMRT (1161.4 ± 315.6) (p < 0.05). The average machine delivery time was 1.5 ± 0.2 minutes for the V-MAT plans, 7.0 ± 1.6 minutes for the 3D-CRT plans, and 11.5 ± 1.9 minutes for the IMRT plans, demonstrating much less delivery time for V-MAT. Based on this preliminary study, V-MAT and IMRT techniques offer improved dose conformity as compared with 3D-CRT techniques without increasing dose to the ipsilateral lung. In terms of MU and delivery time, V-MAT is significantly more efficient for APBI than for conventional 3D-CRT and static-beam IMRT.
Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Accelerated partial-breast irradiation (APBI); IMRT; Intensity-modulated arc therapy; Volumetric-modulated arc therapy (V-MAT)

Mesh:

Year:  2014        PMID: 24480375     DOI: 10.1016/j.meddos.2013.12.001

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  10 in total

1.  The Influence of Treatment Position (Prone vs. Supine) on Clip Displacement, Seroma, Tumor Bed and Partial Breast Target Volumes: Comparative Study.

Authors:  Ferenc Lakosi; Akos Gulyban; Selma Ben-Mustapha Simoni; Paul Viet Nguyen; Séverine Cucchiaro; Laurence Seidel; Levente Janvary; Sophie Nicolas; Peter Vavassis; Philippe Coucke
Journal:  Pathol Oncol Res       Date:  2015-12-16       Impact factor: 3.201

2.  A Dosimetric Comparative Analysis of TomoDirect and Three-Dimensional Conformal Radiotherapy in Early Breast Cancer.

Authors:  Mi Joo Chung; Sung Hwan Kim; Jong Hoon Lee; Young Jin Suh
Journal:  J Breast Cancer       Date:  2015-03-27       Impact factor: 3.588

Review 3.  Intensity modulated radiation therapy for breast cancer: current perspectives.

Authors:  Milly Buwenge; Silvia Cammelli; Ilario Ammendolia; Giorgio Tolento; Alice Zamagni; Alessandra Arcelli; Gabriella Macchia; Francesco Deodato; Savino Cilla; Alessio G Morganti
Journal:  Breast Cancer (Dove Med Press)       Date:  2017-03-06

4.  Dosimetric Comparison of Treatment Plans Using Physical Wedge and Enhanced Dynamic Wedge for the Planning of Breast Radiotherapy.

Authors:  Zhenia Gopalakrishnan; Raghuram K Nair; P Raghukumar; B Sarin
Journal:  J Med Phys       Date:  2018 Jan-Mar

5.  Treatment constraints for single dose external beam preoperative partial breast irradiation in early-stage breast cancer.

Authors:  Ramona K Charaghvandi; Sua Yoo; Bram van Asselen; Anna Rodrigues; Desirée H J G van den Bongard; Janet K Horton
Journal:  Clin Transl Radiat Oncol       Date:  2017-09-08

6.  Multicatheter interstitial brachytherapy versus stereotactic radiotherapy with CyberKnife for accelerated partial breast irradiation: a comparative treatment planning study with respect to dosimetry of organs at risk.

Authors:  András Herein; Gábor Stelczer; Csilla Pesznyák; Georgina Fröhlich; Viktor Smanykó; Norbert Mészáros; Csaba Polgár; Tibor Major
Journal:  Radiol Oncol       Date:  2021-03-25       Impact factor: 2.991

7.  Individually selected teletherapy technique for accelerated partial breast irradiation.

Authors:  Renáta L Kószó; Zsuzsanna Kahán; Barbara Darázs; Ferenc Rárosi; Zoltán Varga
Journal:  Rep Pract Oncol Radiother       Date:  2021-12-30

8.  Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology.

Authors:  Jianjian Qiu; Shujun Zhang; Bo Lv; Xiangpeng Zheng
Journal:  Technol Cancer Res Treat       Date:  2021 Jan-Dec

9.  Performance of a knowledge-based planning model for optimizing intensity-modulated radiotherapy plans for partial breast irradiation.

Authors:  Amy Frederick; Michael Roumeliotis; Petra Grendarova; Sarah Quirk
Journal:  J Appl Clin Med Phys       Date:  2021-12-22       Impact factor: 2.102

10.  External beam accelerated partial breast irradiation: dosimetric assessment of conformal and three different intensity modulated techniques.

Authors:  Gábor Stelczer; Tibor Major; Norbert Mészáros; Csaba Polgár; Csilla Pesznyák
Journal:  Radiol Oncol       Date:  2019-01-19       Impact factor: 2.991

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.