Sensitivity and cross calibration.

A M Paans1, D W Lamotte.   

Abstract

In Positron Emission Tomography it is possible to obtain quantitative information on the distribution of positron emitting radiopharmaceuticals. The different components influencing the sensitivity and the cross calibration of PET systems are discussed especially with respect to the quantitative nature of the PET technique.

Mesh:

Year:  1989        PMID: 2583207     DOI: 10.1007/bf00631771

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  7 in total

1.  Analytical study of a high-resolution positron ring detector system for transaxial reconstruction tomography.

Authors:  S E Derenzo; H Zaklad; T F Budinger
Journal:  J Nucl Med       Date:  1975-12       Impact factor: 10.057

2.  Scatter fraction: measurement and correction.

Authors:  A M Paans; G Rosenqvist; S Holte; L Eriksson; M Dahlbom; C Bohm
Journal:  Eur J Nucl Med       Date:  1989

3.  Quantitation in positron emission computed tomography: 7. A technique to reduce noise in accidental coincidence measurements and coincidence efficiency calibration.

Authors:  M E Casey; E J Hoffman
Journal:  J Comput Assist Tomogr       Date:  1986 Sep-Oct       Impact factor: 1.826

4.  A rotating double-headed positron camera.

Authors:  A M Paans; W Vaalburg; M G Woldring
Journal:  J Nucl Med       Date:  1985-12       Impact factor: 10.057

5.  Analytical study of the performance of a multilayer positron computed tomography scanner.

Authors:  E Tanaka; N Nohara; T Tomitani; M Endo
Journal:  J Comput Assist Tomogr       Date:  1982-04       Impact factor: 1.826

6.  Method for optimizing side shielding in positron-emission tomographs and for comparing detector materials.

Authors:  S E Derenzo
Journal:  J Nucl Med       Date:  1980-10       Impact factor: 10.057

7.  Potential advantages of a cesium fluoride scintillator for a time-of-flight positron camera.

Authors:  R Allemand; C Gresset; J Vacher
Journal:  J Nucl Med       Date:  1980-02       Impact factor: 10.057

  7 in total
  2 in total

1.  Issues in quantification of cardiac PET studies.

Authors:  Hugo W A M de Jong; Mark Lubberink
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-03       Impact factor: 9.236

2.  A method for measuring the absolute sensitivity of positron emission tomographic scanners.

Authors:  D L Bailey; T Jones; T J Spinks
Journal:  Eur J Nucl Med       Date:  1991
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.