Literature DB >> 25824873

Improved tibial component rotation in TKA using patient-specific instrumentation.

Thomas J Heyse1, Carsten O Tibesku.   

Abstract

INTRODUCTION: Patient-specific instrumentation (PSI) was introduced in an attempt to reduce positional outliers of components in total knee arthroplasty (TKA). It was hypothesized that PSI could help with the positioning of tibial components in optimal rotational alignment.
METHODS: A magnetic resonance imaging (MRI) analysis of 58 patients following TKA was conducted. Of these, 30 operations were performed using PSI and 28 using conventional instrumentation. The rotation of the tibial components was determined in MRI using three different reference lines: a tangent to the dorsal tibial condyles, the tibial epicondylar line, and the tibial tubercle. Deviations >9° were considered outliers. Also internal rotation >1° was considered an outlier. Data were analyzed statistically for positional outliers using the Chi-squared test.
RESULTS: There was excellent inter- and intraobserver reliability with low standard deviations for the determination of tibial component rotation using the tangent to the dorsal condyles and the tibial epicondylar line as reference. Using the dorsal tangent as reference, there were eight components in excessive external rotation (28.6 %) and one component being in relative internal rotation (5.4°) in the conventional group, while there were two components in excessive external rotation in the PSI group (6.7 %). Using the tibial epicondyles as reference, there were seven components in excessive external rotation (21.4 %) and one component being in relative internal rotation (4.4°) in the conventional group; while there were two components in excessive external rotation in the PSI group (6.7 %). These differences were statistically significant (p < 0.05). Measurements based on the tibial tubercle showed poor reproducibility in terms of intra- and interobserver reliability and was of little use in the context of the research question. DISCUSSION AND
CONCLUSION: In this setup, PSI was effective in significantly reducing outliers of optimal rotational tibial component alignment during TKA. Anatomy of the proximal tibia does not deliver clear landmarks that are prominent and consistent. This makes both, MRI analysis as well as cutting jig production and intraoperative placement a challenge.

Entities:  

Mesh:

Year:  2015        PMID: 25824873     DOI: 10.1007/s00402-015-2157-2

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  12 in total

Review 1.  Patient specific instrumentation in total knee arthroplasty: a state of the art.

Authors:  Lorenzo Mattei; Pietro Pellegrino; Michel Calò; Alessandro Bistolfi; Filippo Castoldi
Journal:  Ann Transl Med       Date:  2016-04

2.  Internal femoral component malrotation in TKA significantly alters tibiofemoral kinematics.

Authors:  Thomas J Heyse; Bilal F El-Zayat; Ronny De Corte; Yan Chevalier; Susanne Fuchs-Winkelmann; Luc Labey
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-11-11       Impact factor: 4.342

3.  [Total knee arthroplasty with 3D printing technique versus conventional surgery: comparison of the outcomes].

Authors:  Ming Niu; Fei Ma; Ju-Rong Ma; Jun-Wei Li; Xu-Nian Wu; Tong Wang; Yu-Liang Wang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-11-20

4.  Accuracy of tibial cuts with patient-specific instrumentation is not influenced by the surgeon's level of experience.

Authors:  Alexander Antoniadis; Roland S Camenzind; Michael O Schär; Dario Bergadano; Näder Helmy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-06-05       Impact factor: 4.342

5.  Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation.

Authors:  Soheil Mehdipour; Mohamad Qoreishi; Ali Keipourfard
Journal:  Arch Bone Jt Surg       Date:  2020-09

6.  [Total knee arthroplasty with the use of patient specific instruments. The VISIONAIRE system].

Authors:  C O Tibesku
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

7.  [Progress in the method of tibial prosthesis rotation alignment in total knee arthroplasty].

Authors:  Xin Liu; Shengjie Guo; Shuaijie Li; Yanwei Cao; Chuan Xiang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-09-15

8.  Patient-specific instrumentation combined with a new tool for gap balancing is useful in total knee replacement: a 3-year follow-up of a retrospective study.

Authors:  Ting Deng; Tangyou Liu; Qing Lei; Lihong Cai; Song Chen
Journal:  J Orthop Surg Res       Date:  2021-05-12       Impact factor: 2.359

9.  The Effect of Patient-Specific Instrumentation Incorporating an Extramedullary Tibial Guide on Operative Efficiency for Total Knee Arthroplasty.

Authors:  Oh-Ryong Kwon; Kyoung-Tak Kang; Juhyun Son; Dong-Suk Suh; Dong Beom Heo; Yong-Gon Koh
Journal:  Biomed Res Int       Date:  2017-08-03       Impact factor: 3.411

10.  [Clinical application of distal femoral patient-specific cutting guide based on knee CT and full-length X-ray film of lower extremities].

Authors:  Bi Wu; Yue Wang; Peng Hao; Junwei Feng
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-02-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.