Literature DB >> 25807919

Quantitative description of radiofrequency (RF) power-based ratiometric chemical exchange saturation transfer (CEST) pH imaging.

Renhua Wu1, Dario Livio Longo, Silvio Aime, Phillip Zhe Sun.   

Abstract

Chemical exchange saturation transfer (CEST) MRI holds great promise for the imaging of pH. However, routine CEST measurement varies not only with the pH-dependent chemical exchange rate, but also with CEST agent concentration, providing pH-weighted information. Conventional ratiometric CEST imaging normalizes the confounding concentration factor by analyzing the relative CEST effect from different exchangeable groups, requiring CEST agents with multiple chemically distinguishable labile proton sites. Recently, a radiofrequency (RF) power-based ratiometric CEST MRI approach has been developed for concentration-independent pH MRI using CEST agents with a single exchangeable group. To facilitate quantification and optimization of the new ratiometric analysis, we quantified the RF power-based ratiometric CEST ratio (rCESTR) and derived its signal-to-noise and contrast-to-noise ratios. Using creatine as a representative CEST agent containing a single exchangeable site, our study demonstrated that optimized RF power-based ratiometric analysis provides good pH sensitivity. We showed that rCESTR follows a base-catalyzed exchange relationship with pH independent of creatine concentration. The pH accuracy of RF power-based ratiometric MRI was within 0.15-0.20 pH units. Furthermore, the absolute exchange rate can be obtained from the proposed ratiometric analysis. To summarize, RF power-based ratiometric CEST analysis provides concentration-independent pH-sensitive imaging and complements conventional multiple labile proton group-based ratiometric CEST analysis.
Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Keywords:  MRI; chemical exchange saturation transfer (CEST); pH; quantitative CEST (qCEST) analysis; ratiometric CEST analysis

Mesh:

Substances:

Year:  2015        PMID: 25807919      PMCID: PMC4423622          DOI: 10.1002/nbm.3284

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  52 in total

1.  A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST).

Authors:  K M Ward; A H Aletras; R S Balaban
Journal:  J Magn Reson       Date:  2000-03       Impact factor: 2.229

2.  Optimization of the irradiation power in chemical exchange dependent saturation transfer experiments.

Authors:  Phillip Zhe Sun; Peter C M van Zijl; Jinyuan Zhou
Journal:  J Magn Reson       Date:  2005-08       Impact factor: 2.229

3.  Fast radio-frequency enforced steady state (FRESS) spin echo MRI for quantitative T2 mapping: minimizing the apparent repetition time (TR) dependence for fast T2 measurement.

Authors:  Jerry S Cheung; Enfeng Wang; XiaoAn Zhang; Emiri Mandeville; Eng H Lo; A Gregory Sorensen; Phillip Zhe Sun
Journal:  NMR Biomed       Date:  2011-07-14       Impact factor: 4.044

4.  Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): Ph calibration for poly-L-lysine and a starburst dendrimer.

Authors:  Michael T McMahon; Assaf A Gilad; Jinyuan Zhou; Phillip Z Sun; Jeff W M Bulte; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

5.  Magnetic resonance imaging of the Amine-Proton EXchange (APEX) dependent contrast.

Authors:  Tao Jin; Ping Wang; Xiaopeng Zong; Seong-Gi Kim
Journal:  Neuroimage       Date:  2011-08-16       Impact factor: 6.556

6.  Association between pH-weighted endogenous amide proton chemical exchange saturation transfer MRI and tissue lactic acidosis during acute ischemic stroke.

Authors:  Phillip Zhe Sun; Jerry S Cheung; Enfeng Wang; Eng H Lo
Journal:  J Cereb Blood Flow Metab       Date:  2011-03-09       Impact factor: 6.200

7.  Measuring in vivo tumor pHe with CEST-FISP MRI.

Authors:  Vipul R Sheth; Yuguo Li; Liu Qi Chen; Christine M Howison; Chris A Flask; Mark D Pagel
Journal:  Magn Reson Med       Date:  2011-10-25       Impact factor: 4.668

8.  Chemical exchange saturation transfer (CEST): what is in a name and what isn't?

Authors:  Peter C M van Zijl; Nirbhay N Yadav
Journal:  Magn Reson Med       Date:  2011-02-17       Impact factor: 4.668

9.  Optimizing pulsed-chemical exchange saturation transfer imaging sequences.

Authors:  Zhongliang Zu; Ke Li; Vaibhav A Janve; Mark D Does; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2011-03-22       Impact factor: 4.668

10.  Using two chemical exchange saturation transfer magnetic resonance imaging contrast agents for molecular imaging studies.

Authors:  M Meser Ali; Guanshu Liu; Tejas Shah; Chris A Flask; Mark D Pagel
Journal:  Acc Chem Res       Date:  2009-07-21       Impact factor: 22.384

View more
  23 in total

1.  Chemical exchange saturation transfer fingerprinting for exchange rate quantification.

Authors:  Zhengwei Zhou; Pei Han; Bill Zhou; Anthony G Christodoulou; Jaime L Shaw; Zixin Deng; Debiao Li
Journal:  Magn Reson Med       Date:  2018-05-30       Impact factor: 4.668

Review 2.  Cellular and Molecular Imaging Using Chemical Exchange Saturation Transfer.

Authors:  Michael T McMahon; Assaf A Gilad
Journal:  Top Magn Reson Imaging       Date:  2016-10

3.  A method for accurate pH mapping with chemical exchange saturation transfer (CEST) MRI.

Authors:  Phillip Zhe Sun; Gang Xiao; Iris Yuwen Zhou; Yingkun Guo; Renhua Wu
Journal:  Contrast Media Mol Imaging       Date:  2015-12-21       Impact factor: 3.161

4.  A generalized ratiometric chemical exchange saturation transfer (CEST) MRI approach for mapping renal pH using iopamidol.

Authors:  Yin Wu; Iris Y Zhou; Takahiro Igarashi; Dario L Longo; Silvio Aime; Phillip Zhe Sun
Journal:  Magn Reson Med       Date:  2017-07-07       Impact factor: 4.668

5.  Analysis Protocol for the Quantification of Renal pH Using Chemical Exchange Saturation Transfer (CEST) MRI.

Authors:  Hahnsung Kim; Yin Wu; Daisy Villano; Dario Livio Longo; Michael T McMahon; Phillip Zhe Sun
Journal:  Methods Mol Biol       Date:  2021

6.  Rapid and quantitative chemical exchange saturation transfer (CEST) imaging with magnetic resonance fingerprinting (MRF).

Authors:  Ouri Cohen; Shuning Huang; Michael T McMahon; Matthew S Rosen; Christian T Farrar
Journal:  Magn Reson Med       Date:  2018-05-13       Impact factor: 4.668

7.  Quantitative chemical exchange saturation transfer MRI of intervertebral disc in a porcine model.

Authors:  Zhengwei Zhou; Maxim Bez; Wafa Tawackoli; Joseph Giaconi; Dmitriy Sheyn; Sandra de Mel; Marcel M Maya; Barry D Pressman; Zulma Gazit; Gadi Pelled; Dan Gazit; Debiao Li
Journal:  Magn Reson Med       Date:  2016-09-26       Impact factor: 4.668

8.  Amplified detection of phosphocreatine and creatine after supplementation using CEST MRI at high and ultrahigh magnetic fields.

Authors:  KowsalyaDevi Pavuluri; Jens T Rosenberg; Shannon Helsper; Shaowei Bo; Michael T McMahon
Journal:  J Magn Reson       Date:  2020-02-27       Impact factor: 2.229

Review 9.  Two decades of dendrimers as versatile MRI agents: a tale with and without metals.

Authors:  Michael T McMahon; Jeff W M Bulte
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2017-09-11

10.  Developing imidazoles as CEST MRI pH sensors.

Authors:  Xing Yang; Xiaolei Song; Sangeeta Ray Banerjee; Yuguo Li; Youngjoo Byun; Guanshu Liu; Zaver M Bhujwalla; Martin G Pomper; Michael T McMahon
Journal:  Contrast Media Mol Imaging       Date:  2016-04-13       Impact factor: 3.161

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.