Literature DB >> 21871570

Magnetic resonance imaging of the Amine-Proton EXchange (APEX) dependent contrast.

Tao Jin1, Ping Wang, Xiaopeng Zong, Seong-Gi Kim.   

Abstract

Chemical exchange between water and labile protons from amino-acids, proteins and other molecules can be exploited to provide tissue contrast with magnetic resonance imaging (MRI) techniques. Using an off-resonance Spin-Locking (SL) scheme for signal preparation is advantageous because the image contrast can be tuned to specific exchange rates by adjusting SL pulse parameters. While the amide-proton transfer (APT) contrast is obtained optimally with steady-state preparation, using a low power and long irradiation pulse, image contrast from the faster amine-water proton exchange (APEX) is optimized in the transient state with a higher power and a shorter SL pulse. Our phantom experiments show that the APEX contrast is sensitive to protein and amino acid concentration, as well as pH. In vivo 9.4-T SL MRI data of rat brains with irradiation parameters optimized to slow exchange rates have a sharp peak at 3.5 ppm and also broad peak at -2 to -5 ppm, inducing negative contrast in APT-weighted images, while the APEX image has large positive signal resulting from a weighted summation of many different amine-groups. Brain ischemia induced by cardiac arrest decreases pure APT signal from ~1.7% to ~0%, and increases the APEX signal from ~8% to ~16%. In the middle cerebral artery occlusion (MCAO) model, the APEX signal shows different spatial and temporal patterns with large inter-animal variations compared to APT and water diffusion maps. Because of the similarity between the chemical exchange saturation transfer (CEST) and SL techniques, APEX contrast can also be obtained by a CEST approach using similar irradiation parameters. APEX may provide useful information for many diseases involving a change in levels of proteins, peptides, amino-acids, or pH, and may serve as a sensitive neuroimaging biomarker.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21871570      PMCID: PMC3228904          DOI: 10.1016/j.neuroimage.2011.08.014

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  25 in total

1.  A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST).

Authors:  K M Ward; A H Aletras; R S Balaban
Journal:  J Magn Reson       Date:  2000-03       Impact factor: 2.229

2.  R1rho relaxation outside of the fast-exchange limit.

Authors:  Oleg Trott; Arthur G Palmer
Journal:  J Magn Reson       Date:  2002-01       Impact factor: 2.229

3.  Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI.

Authors:  Jinyuan Zhou; Jean-Francois Payen; David A Wilson; Richard J Traystman; Peter C M van Zijl
Journal:  Nat Med       Date:  2003-07-20       Impact factor: 53.440

4.  Quantitative description of proton exchange processes between water and endogenous and exogenous agents for WEX, CEST, and APT experiments.

Authors:  Jinyuan Zhou; David A Wilson; Phillip Zhe Sun; Judith A Klaus; Peter C M Van Zijl
Journal:  Magn Reson Med       Date:  2004-05       Impact factor: 4.668

5.  Optimization of the irradiation power in chemical exchange dependent saturation transfer experiments.

Authors:  Phillip Zhe Sun; Peter C M van Zijl; Jinyuan Zhou
Journal:  J Magn Reson       Date:  2005-08       Impact factor: 2.229

6.  Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain.

Authors:  Jun Hua; Craig K Jones; Jaishri Blakeley; Seth A Smith; Peter C M van Zijl; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2007-10       Impact factor: 4.668

7.  Proton exchange rates from amino acid side chains--implications for image contrast.

Authors:  E Liepinsh; G Otting
Journal:  Magn Reson Med       Date:  1996-01       Impact factor: 4.668

8.  Monitoring disease progression in transgenic mouse models of Alzheimer's disease with proton magnetic resonance spectroscopy.

Authors:  Malgorzata Marjanska; Geoffrey L Curran; Thomas M Wengenack; Pierre-Gilles Henry; Robin L Bliss; Joseph F Poduslo; Clifford R Jack; Kâmil Ugurbil; Michael Garwood
Journal:  Proc Natl Acad Sci U S A       Date:  2005-08-09       Impact factor: 11.205

9.  Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): Ph calibration for poly-L-lysine and a starburst dendrimer.

Authors:  Michael T McMahon; Assaf A Gilad; Jinyuan Zhou; Phillip Z Sun; Jeff W M Bulte; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

10.  Off-resonance spin locking for MR imaging.

Authors:  G E Santyr; E J Fairbanks; F Kelcz; J A Sorenson
Journal:  Magn Reson Med       Date:  1994-07       Impact factor: 4.668

View more
  84 in total

1.  Improved measurement of labile proton concentration-weighted chemical exchange rate (k(ws)) with experimental factor-compensated and T(1) -normalized quantitative chemical exchange saturation transfer (CEST) MRI.

Authors:  Renhua Wu; Charng-Ming Liu; Philip K Liu; Phillip Zhe Sun
Journal:  Contrast Media Mol Imaging       Date:  2012 Jul-Aug       Impact factor: 3.161

2.  Improving the detection sensitivity of pH-weighted amide proton transfer MRI in acute stroke patients using extrapolated semisolid magnetization transfer reference signals.

Authors:  Hye-Young Heo; Yi Zhang; Tina M Burton; Shanshan Jiang; Yansong Zhao; Peter C M van Zijl; Richard Leigh; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2017-06-21       Impact factor: 4.668

3.  Simultaneous detection and separation of hyperacute intracerebral hemorrhage and cerebral ischemia using amide proton transfer MRI.

Authors:  Meiyun Wang; Xiaohua Hong; Che-Feng Chang; Qiang Li; Bo Ma; Hong Zhang; Sinan Xiang; Hye-Young Heo; Yi Zhang; Dong-Hoon Lee; Shanshan Jiang; Richard Leigh; Raymond C Koehler; Peter C M van Zijl; Jian Wang; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2015-04-16       Impact factor: 4.668

4.  Probing chemical exchange using quantitative spin-lock R asymmetry imaging with adiabatic RF pulses.

Authors:  Baiyan Jiang; Tao Jin; Thierry Blu; Weitian Chen
Journal:  Magn Reson Med       Date:  2019-06-24       Impact factor: 4.668

5.  Approximated analytical characterization of the steady-state chemical exchange saturation transfer (CEST) signals.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Magn Reson Med       Date:  2019-06-24       Impact factor: 4.668

6.  Inverse Z-spectrum analysis for spillover-, MT-, and T1 -corrected steady-state pulsed CEST-MRI--application to pH-weighted MRI of acute stroke.

Authors:  Moritz Zaiss; Junzhong Xu; Steffen Goerke; Imad S Khan; Robert J Singer; John C Gore; Daniel F Gochberg; Peter Bachert
Journal:  NMR Biomed       Date:  2014-01-03       Impact factor: 4.044

7.  Contributors to contrast between glioma and brain tissue in chemical exchange saturation transfer sensitive imaging at 3 Tesla.

Authors:  Rachel Scheidegger; Eric T Wong; David C Alsop
Journal:  Neuroimage       Date:  2014-05-20       Impact factor: 6.556

Review 8.  A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging.

Authors:  Jinsuh Kim; Yin Wu; Yingkun Guo; Hairong Zheng; Phillip Zhe Sun
Journal:  Contrast Media Mol Imaging       Date:  2015-01-12       Impact factor: 3.161

9.  Sensitivity-enhanced chemical exchange saturation transfer (CEST) MRI with least squares optimization of Carr Purcell Meiboom Gill multi-echo echo planar imaging.

Authors:  Phillip Zhe Sun; Yu Wang; Jie Lu
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

10.  Observation of true and pseudo NOE signals using CEST-MRI and CEST-MRS sequences with and without lipid suppression.

Authors:  Jianhua Lu; Jinyuan Zhou; Congbo Cai; Shuhui Cai; Zhong Chen
Journal:  Magn Reson Med       Date:  2014-05-06       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.