Literature DB >> 18390341

An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images.

P Coupe1, P Yger, S Prima, P Hellier, C Kervrann, C Barillot.   

Abstract

A critical issue in image restoration is the problem of noise removal while keeping the integrity of relevant image information. Denoising is a crucial step to increase image quality and to improve the performance of all the tasks needed for quantitative imaging analysis. The method proposed in this paper is based on a 3-D optimized blockwise version of the nonlocal (NL)-means filter (Buades, et al., 2005). The NL-means filter uses the redundancy of information in the image under study to remove the noise. The performance of the NL-means filter has been already demonstrated for 2-D images, but reducing the computational burden is a critical aspect to extend the method to 3-D images. To overcome this problem, we propose improvements to reduce the computational complexity. These different improvements allow to drastically divide the computational time while preserving the performances of the NL-means filter. A fully automated and optimized version of the NL-means filter is then presented. Our contributions to the NL-means filter are: 1) an automatic tuning of the smoothing parameter; 2) a selection of the most relevant voxels; 3) a blockwise implementation; and 4) a parallelized computation. Quantitative validation was carried out on synthetic datasets generated with BrainWeb (Collins, et al., 1998). The results show that our optimized NL-means filter outperforms the classical implementation of the NL-means filter, as well as two other classical denoising methods [anisotropic diffusion (Perona and Malik, 1990)] and total variation minimization process (Rudin, et al., 1992) in terms of accuracy (measured by the peak signal-to-noise ratio) with low computation time. Finally, qualitative results on real data are presented .

Mesh:

Year:  2008        PMID: 18390341      PMCID: PMC2881565          DOI: 10.1109/TMI.2007.906087

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  18 in total

1.  A wavelet-based method for improving signal-to-noise ratio and contrast in MR images.

Authors:  M E Alexander; R Baumgartner; A R Summers; C Windischberger; M Klarhoefer; E Moser; R L Somorjai
Journal:  Magn Reson Imaging       Date:  2000-02       Impact factor: 2.546

2.  Complex denoising of MR data via wavelet analysis: application for functional MRI.

Authors:  S Zaroubi; G Goelman
Journal:  Magn Reson Imaging       Date:  2000-01       Impact factor: 2.546

3.  Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR.

Authors:  J C Wood; K M Johnson
Journal:  Magn Reson Med       Date:  1999-03       Impact factor: 4.668

4.  Noise reduction for magnetic resonance images via adaptive multiscale products thresholding.

Authors:  Paul Bao; Lei Zhang
Journal:  IEEE Trans Med Imaging       Date:  2003-09       Impact factor: 10.048

5.  The staircasing effect in neighborhood filters and its solution.

Authors:  Antoni Buades; Bartomeu Coll; Jean-Michel Morel
Journal:  IEEE Trans Image Process       Date:  2006-06       Impact factor: 10.856

6.  Adaptive spatio-temporal restoration for 4D fluorescence microscopic imaging.

Authors:  Jérôme Boulanger; Charles Kervrann; Patrick Bouthemy
Journal:  Med Image Comput Comput Assist Interv       Date:  2005

7.  Efficient and reliable schemes for nonlinear diffusion filtering.

Authors:  J Weickert; B H Romeny; M A Viergever
Journal:  IEEE Trans Image Process       Date:  1998       Impact factor: 10.856

8.  Nonlinear anisotropic filtering of MRI data.

Authors:  G Gerig; O Kubler; R Kikinis; F A Jolesz
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

9.  Wavelet-based Rician noise removal for magnetic resonance imaging.

Authors:  R D Nowak
Journal:  IEEE Trans Image Process       Date:  1999       Impact factor: 10.856

10.  Noise in MRI.

Authors:  A Macovski
Journal:  Magn Reson Med       Date:  1996-09       Impact factor: 4.668

View more
  225 in total

1.  A CANDLE for a deeper in vivo insight.

Authors:  Pierrick Coupé; Martin Munz; Jose V Manjón; Edward S Ruthazer; D Louis Collins
Journal:  Med Image Anal       Date:  2012-01-18       Impact factor: 8.545

2.  Low-dose computed tomography image restoration using previous normal-dose scan.

Authors:  Jianhua Ma; Jing Huang; Qianjin Feng; Hua Zhang; Hongbing Lu; Zhengrong Liang; Wufan Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  A non-local approach for image super-resolution using intermodality priors.

Authors:  François Rousseau
Journal:  Med Image Anal       Date:  2010-05-06       Impact factor: 8.545

4.  The non-local bootstrap--estimation of uncertainty in diffusion MRI.

Authors:  Pew-Thian Yap; Hongyu An; Yasheng Chen; Dinggang Shen
Journal:  Inf Process Med Imaging       Date:  2013

Review 5.  Machine learning in quantitative PET: A review of attenuation correction and low-count image reconstruction methods.

Authors:  Tonghe Wang; Yang Lei; Yabo Fu; Walter J Curran; Tian Liu; Jonathon A Nye; Xiaofeng Yang
Journal:  Phys Med       Date:  2020-07-29       Impact factor: 2.685

6.  BTK: an open-source toolkit for fetal brain MR image processing.

Authors:  François Rousseau; Estanislao Oubel; Julien Pontabry; Marc Schweitzer; Colin Studholme; Mériam Koob; Jean-Louis Dietemann
Journal:  Comput Methods Programs Biomed       Date:  2012-10-01       Impact factor: 5.428

7.  Prediction of Alzheimer's disease in subjects with mild cognitive impairment from the ADNI cohort using patterns of cortical thinning.

Authors:  Simon F Eskildsen; Pierrick Coupé; Daniel García-Lorenzo; Vladimir Fonov; Jens C Pruessner; D Louis Collins
Journal:  Neuroimage       Date:  2012-10-02       Impact factor: 6.556

8.  Combining intraoperative ultrasound brain shift correction and augmented reality visualizations: a pilot study of eight cases.

Authors:  Ian J Gerard; Marta Kersten-Oertel; Simon Drouin; Jeffery A Hall; Kevin Petrecca; Dante De Nigris; Daniel A Di Giovanni; Tal Arbel; D Louis Collins
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-26

9.  Imputation Strategy for Reliable Regional MRI Morphological Measurements.

Authors:  Shaina Sta Cruz; Ivo D Dinov; Megan M Herting; Clio González-Zacarías; Hosung Kim; Arthur W Toga; Farshid Sepehrband
Journal:  Neuroinformatics       Date:  2020-01

10.  Differences in White Matter Microstructure and Connectivity in Nontreatment-Seeking Individuals with Alcohol Use Disorder.

Authors:  Evgeny J Chumin; Joaquín Goñi; Meredith E Halcomb; Timothy C Durazzo; Mario Dzemidzic; Karmen K Yoder
Journal:  Alcohol Clin Exp Res       Date:  2018-04-14       Impact factor: 3.455

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.