Literature DB >> 25792534

Endovascular treatment of wide-neck anterior communicating artery aneurysms using WEB-DL and WEB-SL: short-term results in a multicenter study.

D N Gherasim1, B Gory2, R Sivan-Hoffmann1, L Pierot3, H Raoult4, J-Y Gauvrit4, H Desal5, X Barreau6, D Herbreteau7, R Riva1, F Ambesi Impiombato1, X Armoiry8, F Turjman1.   

Abstract

BACKGROUND AND
PURPOSE: Endovascular treatment of wide-neck anterior communicating artery aneurysms can often be challenging. The Woven EndoBridge (WEB) device is a recently developed intrasaccular flow disrupter dedicated to endovascular treatment of intracranial aneurysms. The aim of this study was to investigate the feasibility, safety, and efficacy of the WEB Dual-Layer and WEB Single-Layer devices for the treatment of wide-neck anterior communicating artery aneurysms.
MATERIALS AND METHODS: Patients with anterior communicating artery aneurysms treated with the WEB device between June 2013 and March 2014 in 5 French centers were analyzed. Procedural success, technical complications, clinical outcome at 1 month, and immediate and 3- to 6-month angiographic follow-up results were analyzed.
RESULTS: Ten patients with unruptured anterior communicating artery aneurysms with a mean neck diameter of 5.4 mm were treated with the WEB. Treatment failed in 3 of the 10 aneurysms without further clinical complications. One patient developed a procedural thromboembolic event, and the other 6 had normal neurologic examination findings at 1-month follow-up. Immediate anatomic outcome evaluation showed adequate occlusion (total occlusion or neck remnant) in 6 of 7 patients. Angiographic control was obtained in all patients, including 6 adequate aneurysm occlusions (3 complete occlusions and 3 neck remnants) at short-term follow-up.
CONCLUSIONS: In our small series, treatment of wide-neck anterior communicating artery aneurysms with the WEB device was feasible and safe. However, patient selection based on the aneurysm and initial angiographic findings in the parent artery is important due to the limitations of the WEB device navigation.
© 2015 by American Journal of Neuroradiology.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25792534      PMCID: PMC8013033          DOI: 10.3174/ajnr.A4282

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  22 in total

1.  WEB intrasaccular flow disruptor-prospective, multicenter experience in 83 patients with 85 aneurysms.

Authors:  C Papagiannaki; L Spelle; A-C Januel; A Benaissa; J-Y Gauvrit; V Costalat; H Desal; F Turjman; S Velasco; X Barreau; P Courtheoux; C Cognard; D Herbreteau; J Moret; L Pierot
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-03       Impact factor: 3.825

2.  WEB device for endovascular treatment of wide-neck bifurcation aneurysms.

Authors:  B Lubicz; B Mine; L Collignon; D Brisbois; G Duckwiler; C Strother
Journal:  AJNR Am J Neuroradiol       Date:  2013-01-04       Impact factor: 3.825

Review 3.  Stent-supported aneurysm coiling: a literature survey of treatment and follow-up.

Authors:  M Shapiro; T Becske; D Sahlein; J Babb; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

4.  Solitaire AB stent-assisted coiling of wide-necked intracranial aneurysms: short-term results from a prospective, consecutive, European multicentric study.

Authors:  Benjamin Gory; Joachim Klisch; Alain Bonafé; Charbel Mounayer; Remy Beaujeux; Jacques Moret; Boris Lubicz; Roberto Riva; Francis Turjman
Journal:  Neuroradiology       Date:  2013-09-22       Impact factor: 2.804

5.  Flow diverters failing to occlude experimental bifurcation or curved sidewall aneurysms: an in vivo study in canines.

Authors:  Tim E Darsaut; Fabrice Bing; Igor Salazkin; Guylaine Gevry; Jean Raymond
Journal:  J Neurosurg       Date:  2012-05-04       Impact factor: 5.115

6.  Solitaire AB stent-assisted coiling of wide-necked intracranial aneurysms: mid-term results from the SOLARE Study.

Authors:  Benjamin Gory; Joachim Klisch; Alain Bonafé; Charbel Mounayer; Remy Beaujeux; Jacques Moret; Boris Lubicz; Roberto Riva; Francis Turjman
Journal:  Neurosurgery       Date:  2014-09       Impact factor: 4.654

7.  Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms.

Authors:  Michel Piotin; Raphaël Blanc; Laurent Spelle; Charbel Mounayer; Rhelen Piantino; Paul J Schmidt; Jacques Moret
Journal:  Stroke       Date:  2009-12-03       Impact factor: 7.914

8.  Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils.

Authors:  Jean Raymond; François Guilbert; Alain Weill; Stavros A Georganos; Louis Juravsky; Anick Lambert; Julie Lamoureux; Miguel Chagnon; Daniel Roy
Journal:  Stroke       Date:  2003-05-29       Impact factor: 7.914

9.  "Y" and "X" stent-assisted coiling of complex and wide-neck intracranial bifurcation aneurysms.

Authors:  B Bartolini; R Blanc; S Pistocchi; H Redjem; M Piotin
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-24       Impact factor: 3.825

10.  Recovery of motor function after stroke.

Authors:  R Bonita; R Beaglehole
Journal:  Stroke       Date:  1988-12       Impact factor: 7.914

View more
  13 in total

Review 1.  "Coil mainly" policy in management of intracranial ACoA aneurysms: single-centre experience with the systematic review of literature and meta-analysis.

Authors:  Anna Steklacova; Ondrej Bradac; Patricia de Lacy; Jiri Lacman; Frantisek Charvat; Vladimir Benes
Journal:  Neurosurg Rev       Date:  2017-11-28       Impact factor: 3.042

2.  WEB Treatment of Ruptured Intracranial Aneurysms.

Authors:  W J van Rooij; J P Peluso; R S Bechan; M Sluzewski
Journal:  AJNR Am J Neuroradiol       Date:  2016-04-21       Impact factor: 3.825

3.  Contrast-Enhanced and Time-of-Flight MRA at 3T Compared with DSA for the Follow-Up of Intracranial Aneurysms Treated with the WEB Device.

Authors:  C Timsit; S Soize; A Benaissa; C Portefaix; J-Y Gauvrit; L Pierot
Journal:  AJNR Am J Neuroradiol       Date:  2016-04-21       Impact factor: 3.825

4.  One-Year Angiographic Follow-Up after WEB-SL Endovascular Treatment of Wide-Neck Bifurcation Intracranial Aneurysms.

Authors:  R Sivan-Hoffmann; B Gory; R Riva; P-E Labeyrie; F Signorelli; I Eldesouky; U Gonike-Sadeh; X Armoiry; F Turjman
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-20       Impact factor: 3.825

5.  The RISE trial: A Randomized Trial on Intra-Saccular Endobridge devices.

Authors:  Jean Raymond; Anne-Christine Januel; Daniela Iancu; Daniel Roy; Alain Weill; Andrew Carlson; Tim E Darsaut
Journal:  Interv Neuroradiol       Date:  2019-11-05       Impact factor: 1.610

6.  Endovascular treatment of bifurcation intracranial aneurysms with the WEB SL/SLS: 6-month clinical and angiographic results.

Authors:  Patricia Bozzetto Ambrosi; Benjamin Gory; Rotem Sivan-Hoffmann; Roberto Riva; Francesco Signorelli; Paul-Emile Labeyrie; Islam Eldesouky; Udi Sadeh-Gonike; Xavier Armoiry; Francis Turjman
Journal:  Interv Neuroradiol       Date:  2015-06-25       Impact factor: 1.610

7.  Incidence and predictors of headache relief after endovascular treatment in patients with unruptured intracranial aneurysms.

Authors:  Wenjun Ji; Aihua Liu; Xinjian Yang; Youxiang Li; Chuhan Jiang; Zhongxue Wu
Journal:  Interv Neuroradiol       Date:  2016-09-22       Impact factor: 1.610

8.  The Woven EndoBridge (WEB) as primary treatment for unruptured intracranial aneurysms.

Authors:  Sanne Bt van Rooij; Willem Jan van Rooij; Jo P Peluso; Menno Sluzewski
Journal:  Interv Neuroradiol       Date:  2018-05-16       Impact factor: 1.610

9.  PulseRider Stent-Assisted Coiling of Wide-Neck Bifurcation Aneurysms: Periprocedural Results in an International Series.

Authors:  B Gory; A M Spiotta; S Mangiafico; A Consoli; A Biondi; E Pomero; M Killer-Oberpfalzer; W Weber; R Riva; P E Labeyrie; F Turjman
Journal:  AJNR Am J Neuroradiol       Date:  2015-09-03       Impact factor: 3.825

10.  Evaluation of the Angiographic Grading Scale in Aneurysms Treated with the WEB Device in 80 Rabbits: Correlation with Histologic Evaluation.

Authors:  A Rouchaud; W Brinjikji; Y-H Ding; D Dai; Y Q Zhu; H J Cloft; D F Kallmes; R Kadirvel
Journal:  AJNR Am J Neuroradiol       Date:  2015-09-24       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.