Literature DB >> 24818784

Solitaire AB stent-assisted coiling of wide-necked intracranial aneurysms: mid-term results from the SOLARE Study.

Benjamin Gory1, Joachim Klisch, Alain Bonafé, Charbel Mounayer, Remy Beaujeux, Jacques Moret, Boris Lubicz, Roberto Riva, Francis Turjman.   

Abstract

BACKGROUND: Endovascular treatment of intracranial aneurysms can be technically difficult when the neck is wide. The Solitaire AB stent (Covidien, Irvine, California), the only fully retrieved stent, assists in the coiling of wide-neck intracranial aneurysms.
OBJECTIVE: To evaluate the mid-term angiographic follow-up of wide-necked aneurysms treated with the Solitaire AB stent.
METHODS: SOLARE (SOLitaire Aneurysm Remodeling) is a consecutive, prospective study conducted in 7 European centers. A core laboratory evaluated the postoperative and mid-term (6 month ± 15 days) angiographic results by using the Raymond classification Scale. Recanalization was defined as worsening, and progressive thrombosis was defined as improvement in the Raymond scale score.
RESULTS: The mean width of the aneurysm sac was 7.5 mm, and the mean diameter of the aneurysm neck was 4.7 mm. Angiographic mid-term follow-up was obtained in 55 of 65 aneurysms (85.9%). Complete occlusion was achieved in 33 aneurysms (60%); a neck remnant was seen in 16 aneurysms (29.1%) and an aneurysm remnant in 6 aneurysms (10.9%). Of 55 aneurysms, recanalization was observed in 8 aneurysms (14.5%), and progressive thrombosis was observed in 17 aneurysms (30.9%). No bleeding or rebleeding was observed during the follow-up period.
CONCLUSION: Stent-assisted coiling of wide-necked intracranial aneurysms was found to be safe and effective with the Solitaire AB stent at 6-month follow-up. Angiographic results improve with time due to progressive thrombosis of the aneurysm.

Entities:  

Mesh:

Year:  2014        PMID: 24818784     DOI: 10.1227/NEU.0000000000000415

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  18 in total

1.  One-Year Angiographic Follow-Up after WEB-SL Endovascular Treatment of Wide-Neck Bifurcation Intracranial Aneurysms.

Authors:  R Sivan-Hoffmann; B Gory; R Riva; P-E Labeyrie; F Signorelli; I Eldesouky; U Gonike-Sadeh; X Armoiry; F Turjman
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-20       Impact factor: 3.825

2.  Stent-Assisted Coiling of Wide-Neck Intracranial Aneurysms Using Low-Profile LEO Baby Stents: Initial and Midterm Results.

Authors:  K Aydin; A Arat; S Sencer; M Barburoglu; S Men
Journal:  AJNR Am J Neuroradiol       Date:  2015-05-28       Impact factor: 3.825

3.  Endovascular treatment of bifurcation intracranial aneurysms with the WEB SL/SLS: 6-month clinical and angiographic results.

Authors:  Patricia Bozzetto Ambrosi; Benjamin Gory; Rotem Sivan-Hoffmann; Roberto Riva; Francesco Signorelli; Paul-Emile Labeyrie; Islam Eldesouky; Udi Sadeh-Gonike; Xavier Armoiry; Francis Turjman
Journal:  Interv Neuroradiol       Date:  2015-06-25       Impact factor: 1.610

4.  Endovascular treatment of wide-neck anterior communicating artery aneurysms using WEB-DL and WEB-SL: short-term results in a multicenter study.

Authors:  D N Gherasim; B Gory; R Sivan-Hoffmann; L Pierot; H Raoult; J-Y Gauvrit; H Desal; X Barreau; D Herbreteau; R Riva; F Ambesi Impiombato; X Armoiry; F Turjman
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-19       Impact factor: 3.825

5.  pCONus Device for the Endovascular Treatment of Wide-Neck Middle Cerebral Artery Aneurysms.

Authors:  B Gory; M Aguilar-Pérez; E Pomero; F Turjman; W Weber; S Fischer; H Henkes; A Biondi
Journal:  AJNR Am J Neuroradiol       Date:  2015-07-23       Impact factor: 3.825

6.  Results of Temporary Stent-assisted Coil Embolization (CATS) for the Treatment of Wide-neck Aneurysms : A 10-year Single Center Experience.

Authors:  F Gottmann; O Nikoubashman; A Höllig; A Reich; M Wiesmann
Journal:  Clin Neuroradiol       Date:  2022-08-26       Impact factor: 3.156

7.  PulseRider Stent-Assisted Coiling of Wide-Neck Bifurcation Aneurysms: Periprocedural Results in an International Series.

Authors:  B Gory; A M Spiotta; S Mangiafico; A Consoli; A Biondi; E Pomero; M Killer-Oberpfalzer; W Weber; R Riva; P E Labeyrie; F Turjman
Journal:  AJNR Am J Neuroradiol       Date:  2015-09-03       Impact factor: 3.825

8.  Primary Stenting for Acute Ischemic Stroke Using the Enterprise Intracranial Stent: 2-Year Results of a Phase-I Trial.

Authors:  Sabareesh K Natarajan; Ashish Sonig; J Mocco; Travis M Dumont; Harjot Thind; Mary L Hartney; Kenneth V Snyder; L Nelson Hopkins; Adnan H Siddiqui; Elad I Levy
Journal:  J Vasc Interv Neurol       Date:  2015-07

9.  EVIDENCE trial: design of a phase 2, randomized, controlled, multicenter study comparing flow diversion and traditional endovascular strategy in unruptured saccular wide-necked intracranial aneurysms.

Authors:  Francis Turjman; Olivier Levrier; Xavier Combaz; Alain Bonafé; Alessandra Biondi; Hubert Desal; Serge Bracard; Charbel Mounayer; Roberto Riva; Francois Chapuis; Laure Huot; Xavier Armoiry; Benjamin Gory
Journal:  Neuroradiology       Date:  2014-10-04       Impact factor: 2.804

10.  The Use of Solitaire AB Stents in Coil Embolization of Wide-Necked Cerebral Aneurysms.

Authors:  Teng-Fei Li; Shao-Feng Shui; Xin-Wei Han; Lei Yan; Ji Ma; Dong Guo; Hong-Can Zhu; Shu-Kai Wang; Yuan-Hong He; Wen-Wu Chen; Li-Ping Wei; Ming-Ke Wang; Tai-Min Song
Journal:  PLoS One       Date:  2015-10-01       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.