Literature DB >> 25745539

An Integrated X-Ray/Optical Tomography System for Pre-clinical Radiation Research.

S Eslami1, Y Yang2, J Wong2, M S Patterson3, I Iordachita1.   

Abstract

The current Small Animal Radiation Research Platform (SARRP) is poor for localizing small soft tissue targets for irradiation or tumor models growing in a soft tissue environment. Therefore, an imaging method complementary to x-ray CT is required to localize the soft tissue target's Center of Mass (CoM) to within 1 mm. In this paper, we report the development of an integrated x-ray/bioluminescence imaging/tomography (BLI/BLT) system to provide a pre-clinical, high resolution irradiation system. This system can be used to study radiation effects in small animals under the conebeam computed tomography (CBCT) imaging guidance by adding the bioluminescence imaging (BLI) system as a standalone system which can also be docked onto the SARRP. The proposed system integrates two robotic rotating stages and an x-ray source rated at maximum 130 kVp and having a small variable focal spot. A high performance and low noise CCD camera mounted in a light-tight housing along with an optical filter assembly is used for multi-wavelength BL tomography. A three-mirror arrangement is implemented to eliminate the need of rotating the CCD camera for acquiring multiple views. The mirror system is attached to a motorized stage to capture images in angles between 0-90° (for the standalone system). Camera and CBCT calibration are accomplished.

Entities:  

Keywords:  CBCT; bioluminescent tomography; small animal radiation research platform; x-ray

Year:  2013        PMID: 25745539      PMCID: PMC4347524          DOI: 10.1117/12.2008060

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  10 in total

1.  A geometric calibration method for cone beam CT systems.

Authors:  Kai Yang; Alexander L C Kwan; DeWitt F Miller; John M Boone
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

2.  Small animal radiation research platform: imaging, mechanics, control and calibration.

Authors:  Mohammad Matinfar; Owen Gray; Iulian Iordachita; Chris Kennedy; Eric Ford; John Wong; Russell H Taylor; Peter Kazanzides
Journal:  Med Image Comput Comput Assist Interv       Date:  2007

3.  MicroRT-small animal conformal irradiator.

Authors:  S Stojadinovic; D A Low; A J Hope; M Vicic; J O Deasy; J Cui; D Khullar; P J Parikh; K T Malinowski; E W Izaguirre; S Mutic; P W Grigsby
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

4.  Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner.

Authors:  Edward E Graves; Hu Zhou; Raja Chatterjee; Paul J Keall; Sanjiv Sam Gambhir; Christopher H Contag; Arthur L Boyer
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

5.  A novel high resolution micro-radiotherapy system for small animal irradiation for cancer research.

Authors:  Sigen Wang; Zhijun Liu; Shabana Sultana; Eric Schreiber; Otto Zhou; Sha Chang
Journal:  Biofactors       Date:  2007       Impact factor: 6.113

6.  3D image-guided robotic needle positioning system for small animal interventions.

Authors:  Jeffrey S Bax; Christopher S R Waring; Shi Sherebrin; Shawn Stapleton; Thomas J Hudson; David A Jaffray; James C Lacefield; Aaron Fenster
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

7.  Auto calibration of a cone-beam-CT.

Authors:  Daniel Gross; Ulrich Heil; Ralf Schulze; Elmar Schoemer; Ulrich Schwanecke
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

8.  Image-guided small animal radiation research platform: calibration of treatment beam alignment.

Authors:  Mohammad Matinfar; Eric Ford; Iulian Iordachita; John Wong; Peter Kazanzides
Journal:  Phys Med Biol       Date:  2009-01-14       Impact factor: 3.609

9.  High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities.

Authors:  John Wong; Elwood Armour; Peter Kazanzides; Iulian Iordachita; Erik Tryggestad; Hua Deng; Mohammad Matinfar; Christopher Kennedy; Zejian Liu; Timothy Chan; Owen Gray; Frank Verhaegen; Todd McNutt; Eric Ford; Theodore L DeWeese
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-08-01       Impact factor: 7.038

10.  In vivo optical imaging of tumor and microvascular response to ionizing radiation.

Authors:  Azusa Maeda; Michael K K Leung; Leigh Conroy; Yonghong Chen; Jiachuan Bu; Patricia E Lindsay; Shani Mintzberg; Carl Virtanen; Julissa Tsao; Neil A Winegarden; Yanchun Wang; Lily Morikawa; I Alex Vitkin; David A Jaffray; Richard P Hill; Ralph S DaCosta
Journal:  PLoS One       Date:  2012-08-22       Impact factor: 3.240

  10 in total
  1 in total

1.  Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research.

Authors:  Yidong Yang; Ken Kang-Hsin Wang; Sohrab Eslami; Iulian I Iordachita; Michael S Patterson; John W Wong
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

  1 in total