Literature DB >> 16527629

Accuracy of digital and analogue cephalometric measurements assessed with the sandwich technique.

Margherita Santoro1, Karim Jarjoura, Thomas J Cangialosi.   

Abstract

INTRODUCTION: The purpose of the study was to evaluate the accuracy of cephalometric measurements obtained with digital tracing software compared with equivalent hand-traced measurements. In the sandwich technique, a storage phosphor plate and a conventional radiographic film are placed in the same cassette and exposed simultaneously. The method eliminates positioning errors and potential differences associated with multiple radiographic exposures that affected previous studies. It was used to ensure the equivalence of the digital images to the hard copy radiographs. Cephalometric measurements instead of landmarks were the focus of this investigation in order to acquire data with direct clinical applications.
METHODS: The sample consisted of digital and analog radiographic images from 47 patients after orthodontic treatment. Nine cephalometric landmarks were identified and 13 measurements calculated by 1 operator, both manually and with digital tracing software. Measurement error was assessed for each method by duplicating measurements of 25 randomly selected radiographs and by using Pearson's correlation coefficient. A paired t test was used to detect differences between the manual and digital methods.
RESULTS: An overall greater variability in the digital cephalometric measurements was found. Differences between the 2 methods for SNA, ANB, S-Go:N-Me, U1/L1, L1-GoGn, and N-ANS:ANS-Me were statistically significant (P < .05). However, only the U1/L1 and S-Go:N-Me measurements showed differences greater than 2 SE (P < .0001).
CONCLUSIONS: The 2 tracing methods provide similar clinical results; therefore, efficient digital cephalometric software can be reliably chosen as a routine diagnostic tool. The user-friendly sandwich technique was effective as an option for interoffice communications.

Entities:  

Mesh:

Year:  2006        PMID: 16527629     DOI: 10.1016/j.ajodo.2005.12.010

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  17 in total

1.  The reliability and reproducibility of cephalometric measurements: a comparison of conventional and digital methods.

Authors:  S F Albarakati; K S Kula; A A Ghoneima
Journal:  Dentomaxillofac Radiol       Date:  2012-01       Impact factor: 2.419

2.  Comparison of linear and angular measurements using two-dimensional conventional methods and three-dimensional cone beam CT images reconstructed from a volumetric rendering program in vivo.

Authors:  U Oz; K Orhan; N Abe
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

3.  Novel information theory based method for superimposition of lateral head radiographs and cone beam computed tomography images.

Authors:  W Jacquet; E Nyssen; P Bottenberg; P de Groen; B Vande Vannet
Journal:  Dentomaxillofac Radiol       Date:  2010-05       Impact factor: 2.419

4.  Accuracy and repeatability of computer aided cervical vertebra landmarking in cephalogram.

Authors:  Lili Chen; Zhicong Lan; Xiangyang Xu; Jiuxiang Lin; Huaifei Hu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2012-01-27

5.  Comparative evaluation of cephalometric measurements of monitor-displayed images by Nemoceph software and its hard copy by manual tracing.

Authors:  Tripti Tikku; Rohit Khanna; R P Maurya; Kamna Srivastava; Rastra Bhushan
Journal:  J Oral Biol Craniofac Res       Date:  2014-01-08

6.  Concurrent validity and reliability of cephalometric analysis using smartphone apps and computer software.

Authors:  Christos Livas; Konstantina Delli; Frederik K L Spijkervet; Arjan Vissink; Pieter U Dijkstra
Journal:  Angle Orthod       Date:  2019-07-08       Impact factor: 2.079

7.  The reliability and reproducibility of an Android cephalometric smartphone application in comparison with the conventional method.

Authors:  Obada M Zamrik; Haluk İşeri
Journal:  Angle Orthod       Date:  2021-03-01       Impact factor: 2.079

8.  Assessing the Reliability of Digitalized Cephalometric Analysis in Comparison with Manual Cephalometric Analysis.

Authors:  Mohammed Umar Farooq; Mohd Asadullah Khan; Shahid Imran; Ayesha Sameera; Arshad Qureshi; Syed Afroz Ahmed; Sujan Kumar; Mohd Aziz Ur Rahman
Journal:  J Clin Diagn Res       Date:  2016-10-01

9.  Comparison of manual, digital and lateral CBCT cephalometric analyses.

Authors:  Ricardo de Lima Navarro; Paula Vanessa Pedron Oltramari-Navarro; Thais Maria Freire Fernandes; Giovani Fidelis de Oliveira; Ana Cláudia de Castro Ferreira Conti; Marcio Rodrigues de Almeida; Renato Rodrigues de Almeida
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

10.  An evaluation of cellular neural networks for the automatic identification of cephalometric landmarks on digital images.

Authors:  Rosalia Leonardi; Daniela Giordano; Francesco Maiorana
Journal:  J Biomed Biotechnol       Date:  2009-09-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.