| Literature DB >> 28155649 |
Mogeeb Ahmed Ahmed Mosleh1, Mohd Sapiyan Baba2, Sorayya Malek2, Rasheed A Almaktari3.
Abstract
BACKGROUND: Cephalometric analysis and measurements of skull parameters using X-Ray images plays an important role in predicating and monitoring orthodontic treatment. Manual analysis and measurements of cephalometric is considered tedious, time consuming, and subjected to human errors. Several cephalometric systems have been developed to automate the cephalometric procedure; however, no clear insights have been reported about reliability, performance, and usability of those systems. This study utilizes some techniques to evaluate reliability, performance, and usability metric using SUS methods of the developed cephalometric system which has not been reported in previous studies.Entities:
Keywords: Automated cephalometric; Computer-aided biomedical image; Digital image processing; Evaluation cephalometric system
Mesh:
Year: 2016 PMID: 28155649 PMCID: PMC5259857 DOI: 10.1186/s12859-016-1370-5
Source DB: PubMed Journal: BMC Bioinformatics ISSN: 1471-2105 Impact factor: 3.169
Fig. 1Cephalometric Landmark Points
Fig. 2Manual Cephalometric Sample
Fig. 3Automatic Cephalometric Sample using Ceph-X
Cephalometric parameters used in this study
| Landmark Points (11) | Lines (12) | Angles (6) |
|---|---|---|
| N: Nasion | Po - Or | SNA |
| S: Sella | ANS - PNS | SNB |
| Po: Porion | Me - Go | ANB |
| Or: Orbitale | S – N | FMA |
| Ar: Articulare | N – A | PMP |
| Go: Gonion | N-B | NSAR |
| Me: Menton | N-Me | |
| ANS: Anterior nasal spine | N-ANS | |
| PNS: Posterior nasal spine | ANS-Me | |
| Point A: sub spinal | S-Go | |
| Point B: supramental | S-Ar | |
| Ar-Go |
Fig. 4Ceph-X image processing steps. (a) Original Image, (b) original image after applied Unsharp filter, (c) original image after applied Gaussian filter
Fig. 5Ceph-X interface during locating landmark points
Comparison results for linear measurements
| parameter/Case | Automatic | Manual |
| ||
|---|---|---|---|---|---|
| Mean | SD | Mean | SD | ||
| Po - Or | 7.39 | 0.534 | 7.59 | 0.652 | 0.01 |
| ANS - PNS | 4.66 | 0.217 | 4.74 | 0.25 | 0.0016 |
| Me - Go | 5.72 | 0.397 | 5.85 | 0.497 | 0.004225 |
| S – N | 6.36 | 0.241 | 6.44 | 0.207 | 0.0016 |
| N - A | 4.63 | 0.309 | 4.74 | 0.299 | 0.003025 |
| N - B | 5.74 | 0.317 | 5.87 | 0.333 | 0.004225 |
| N-Me | 10.53 | 0.678 | 10.76 | 0.706 | 0.013225 |
| N-ANS | 4.42 | 0.257 | 4.44 | 0.28 | 0.0001 |
| ANS-Me | 6.4 | 0.641 | 6.53 | 0.432 | 0.004225 |
| S-Go | 7.5 | 0.365 | 7.64 | 0.417 | 0.0049 |
| S-Ar | 3.14 | 0.384 | 3.11 | 0.431 | 0.000225 |
| Ar-Go | 4.71 | 0.401 | 4.8 | 0.371 | 0.002025 |
Comparison results for angular measurements
| Parameter/Case | Automatic | Manual |
| ||
|---|---|---|---|---|---|
| Mean | SD | Mean | SD | ||
| SNA | 90.61 | 2.22 | 90.7 | 2.97 | 0.002025 |
| SNB | 86.56 | 1 | 86.6 | 1.72 | 0.0004 |
| ANB | 4.09 | 1.75 | 4.1 | 1.52 | 0.000025 |
| F.M.A | 33.6 | 1.41 | 33.9 | 1.9 | 0.0225 |
| PP-MP | 32.9 | 1.89 | 33.3 | 1.54 | 0.04 |
| N.S.Ar | 112.5 | 1.85 | 112.8 | 1.22 | 0.0225 |
Comparison results of performance evaluation
| Time Parameter | Manual ( | Automatic ( |
|
|---|---|---|---|
| Locating Landmarks | 1.72 0.26 | .62 0.12 | * |
| Cephalometric Tracing | 10.45 0.46 | 0.73 0.1 | * |
| Measurements | 14.17 1.52 | .2 | * |
*Significant difference between Manual and automatic groups at P <0.05