Literature DB >> 33679038

Functional outcomes & metal ion levels following ceramic on metal total hip arthroplasty: 9 Year follow-up.

Nisarg Mehta1, Dhawal Patel1, Justin Leong2, Phil Brown3, Fintan Adrian Carroll1.   

Abstract

In this study, we evaluate the mid-term functional and radiological outcomes of Ceramic on Metal Total Hip Arthroplasty (CoM THA) THA. 66 CoM THAs were performed between 2008 and 2010. These were evaluated and followed up in 2017-18, at a mean follow-up of 9 years to record the Oxford Hip Score [OHS] and whole blood Cobalt and Chrome levels. Our all cause revision rate was 4.5% (3 out of 66). At mid-term follow up, patients with CoM THAs are mostly asymptomatic with reasonable functional outcomes, we have reported similar revision rates in conjunction with raised blood metal ion levels and frequency of radiolucent lines.
© 2021 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Arthroplasty; Ceramic on metal; Chromium levels; Cobalt levels

Year:  2021        PMID: 33679038      PMCID: PMC7930504          DOI: 10.1016/j.jor.2021.02.030

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  12 in total

1.  A new tool for measuring cup orientation in total hip arthroplasties from plain radiographs.

Authors:  Chen-Kun Liaw; Sheng-Mou Hou; Rong-Sen Yang; Tai-Yin Wu; Chiou-Shann Fuh
Journal:  Clin Orthop Relat Res       Date:  2006-10       Impact factor: 4.176

2.  Revision rates for metal on metal hip joints are double that of other materials.

Authors:  Deborah Cohen
Journal:  BMJ       Date:  2011-09-20

3.  A prospective study of a ceramic-on-metal bearing in total hip arthroplasty. Clinical results, metal ion levels and chromosome analysis at two years.

Authors:  H A Kazi; J R Perera; E Gillott; F A Carroll; T W R Briggs
Journal:  Bone Joint J       Date:  2013-08       Impact factor: 5.082

4.  A prospective study of ceramic-on-metal bearings in total hip arthroplasty at four-year follow-up: clinical results, metal ion levels, inflammatory factor levels, and liver-kidney function.

Authors:  Yi Zeng; Bo Zheng; Bin Shen; Jing Yang; Zongke Zhou; Pengde Kang; Fuxing Pei
Journal:  J Orthop Sci       Date:  2014-12-23       Impact factor: 1.601

5.  The natural history and significance of radiolucent lines at a cemented femoral interface.

Authors:  H Iwaki; G Scott; M A R Freeman
Journal:  J Bone Joint Surg Br       Date:  2002-05

6.  A prospective, randomised controlled trial comparing ceramic-on-metal and metal-on-metal bearing surfaces in total hip replacement.

Authors:  R Schouten; A A Malone; C Tiffen; C M Frampton; G Hooper
Journal:  J Bone Joint Surg Br       Date:  2012-11

7.  Five-year follow-up of a prospective randomised trial comparing ceramic-on-metal and metal-on-metal bearing surfaces in total hip arthroplasty.

Authors:  R Schouten; A A Malone; C M Frampton; C Tiffen; G Hooper
Journal:  Bone Joint J       Date:  2017-10       Impact factor: 5.082

8.  Ceramic-on-metal bearing in short stem total hip arthroplasty: ions, functional and radiographic evaluation at mid-term follow-up.

Authors:  Michela Saracco; Giulio Maccauro; Andrea Urbani; Domenico Ciavardelli; Silvia Persichilli; Giulio Ancillai; Patrizio Pasqualetti; Vittorio Calvisi; Giandomenico Logroscino
Journal:  Hip Int       Date:  2020-12       Impact factor: 2.135

9.  Meaningful changes for the Oxford hip and knee scores after joint replacement surgery.

Authors:  David J Beard; Kristina Harris; Jill Dawson; Helen Doll; David W Murray; Andrew J Carr; Andrew J Price
Journal:  J Clin Epidemiol       Date:  2014-10-31       Impact factor: 6.437

10.  Early Results of Our International, Multicenter, Multisurgeon, Double-Blinded, Prospective, Randomized, Controlled Trial Comparing Metal-on-Metal With Ceramic-on-Metal in Total Hip Arthroplasty.

Authors:  Joanna E Higgins; Kevin S Conn; John M Britton; Maija Pesola; Mikko Manninen; Geoff J Stranks
Journal:  J Arthroplasty       Date:  2019-08-22       Impact factor: 4.757

View more
  1 in total

1.  Ceramic-on-metal coupling in THA: long term clinical and radiographic outcomes using two different short stems.

Authors:  Giandomenico Logroscino; Michela Saracco; Giulio Maccauro; Andrea Urbani; Domenico Ciavardelli; Ada Consalvo; Daniele Ferraro; Francesco Falez
Journal:  BMC Musculoskelet Disord       Date:  2022-02-22       Impact factor: 2.362

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.