Literature DB >> 29881190

Silicone ring tourniquet versus pneumatic cuff tourniquet in total knee arthroplasty surgery: A randomised comparative study.

Vicente J León-Muñoz1, Alonso J Lisón-Almagro1, César H Hernández-García1, Mirian López-López2.   

Abstract

INTRODUCTION: The aim of the present study was to compare a silicone ring tourniquet (SRT) and a classic pneumatic cuff tourniquet (PT) in patients undergoing total knee replacement. We have compared the impact on the glycolytic activity caused by the ischaemia applied to the limb during the surgery.
MATERIAL AND METHODS: 140 patients that underwent total knee arthroplasty (TKA) were randomised in two groups. Serum lactate determination was made by reactive strips of enzymatic-amperometric detection, 5 min before tourniquet application and 5 min after tourniquet removal.
RESULTS: The mean tourniquet time was similar for both groups (p 0.13). Postoperative serum lactate levels were higher with statistical significance than the preoperative levels and with a positive Pearson´s correlation in the overall cases. The postoperative serum lactate levels where higher in the PT group (4.097 ± 2.248 mmol/L) than the SRT group (3.499 ± 1.566 mmol/L). There was no significant difference (p 0.07) to be able to affirm that there was a difference of the anaerobic metabolism according to the tourniquet system used. DISCUSSION: Ischaemia applied to the lower extremity during knee replacement surgery can produce tissue injury. Serum lactate determination allows comparison of the ischaemic changes during TKA surgery caused by two different tourniquet systems.
CONCLUSIONS: SRT may be not disadvantageous compared to the classic PT from the impact on the glycolytic activity caused by the ischaemia.Level of evidence II.

Entities:  

Keywords:  Pneumatic cuff tourniquet; Silicone ring tourniquet; Total knee arthroplasty

Year:  2018        PMID: 29881190      PMCID: PMC5990291          DOI: 10.1016/j.jor.2018.05.025

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  22 in total

1.  Tourniquet time affects postoperative complications after knee arthroplasty.

Authors:  Charlotta Olivecrona; Lasse J Lapidus; Lina Benson; Richard Blomfeldt
Journal:  Int Orthop       Date:  2013-02-16       Impact factor: 3.075

2.  Influence of wound drainage in primary total knee arthroplasty without tourniquet.

Authors:  Sven Märdian; Georg Matziolis; Philipp Schwabe
Journal:  Int Orthop       Date:  2014-08-21       Impact factor: 3.075

Review 3.  The effect of ischemia reperfusion injury on skeletal muscle.

Authors:  Syed Gillani; Jue Cao; Takashi Suzuki; David J Hak
Journal:  Injury       Date:  2011-04-09       Impact factor: 2.586

4.  Silicone ring tourniquet or pneumatic cuff tourniquet for total knee arthroplasty.

Authors:  Jean-Yves Jenny; David Bahlau; Sandra Wisniewski
Journal:  Int Orthop       Date:  2016-03-16       Impact factor: 3.075

5.  Silicone ring versus pneumatic cuff tourniquet: a comparative quantitative study in healthy individuals.

Authors:  Georgios I Drosos; Nikolaos I Stavropoulos; Konstantinos Kazakos; Grigorios Tripsianis; Athanasios Ververidis; Dionisios-Alexandros Verettas
Journal:  Arch Orthop Trauma Surg       Date:  2010-06-29       Impact factor: 3.067

6.  The Sterile Elastic Exsanguination Tourniquet vs. the Pneumatic Tourniquet for Total Knee Arthroplasty.

Authors:  Yaron S Brin; Viktor Feldman; Itai Ron Gal; Michael Markushevitch; Amit Regev; Abraham Stern
Journal:  J Arthroplasty       Date:  2014-11-26       Impact factor: 4.757

7.  Tourniquet-induced ischaemia during total knee arthroplasty results in higher proteolytic activities within vastus medialis cells: a randomized clinical trial.

Authors:  Ahmed Jawhar; Stephan Hermanns; Norbert Ponelies; Udo Obertacke; Henning Roehl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-14       Impact factor: 4.342

8.  Effects of tourniquet use on blood loss and soft-tissue damage in total knee arthroplasty: a randomized controlled trial.

Authors:  Ta-Wei Tai; Chih-Wei Chang; Kuo-An Lai; Chii-Jeng Lin; Chyun-Yu Yang
Journal:  J Bone Joint Surg Am       Date:  2012-12-19       Impact factor: 5.284

9.  Tourniquet-induced ischemia and reperfusion in human skeletal muscle.

Authors:  Bengt Ostman; Karl Michaelsson; Hans Rahme; Lars Hillered
Journal:  Clin Orthop Relat Res       Date:  2004-01       Impact factor: 4.176

10.  Capillary lactate concentration on admission of normotensive trauma patients: a prospective study.

Authors:  Pierre Bouzat; Clotilde Schilte; Marc Vinclair; Pauline Manhes; Julien Brun; Jean-Luc Bosson; Jean-François Payen
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-06-07       Impact factor: 2.953

View more
  3 in total

1.  Comparison of local pain and tissue reaction between conventional pneumatic tourniquet and disposable silicone ring tourniquet during Total Knee Arthroplasty.

Authors:  Sanjay Bhalchandra Londhe; Ravi Vinod Shah; Shubhankar Sanjay Londhe; Pritesh Omprakash Agrawal; Nicholas A Antao; Sushil Churhe
Journal:  J Clin Orthop Trauma       Date:  2020-09-09

2.  Elastic pneumatic tourniquet cuff can reduce postoperative thigh pain after total knee arthroplasty: a prospective randomized trial.

Authors:  Jae-Young Park; Sung Eun Kim; Myung Chul Lee; Hyuk-Soo Han
Journal:  BMC Musculoskelet Disord       Date:  2020-08-21       Impact factor: 2.362

Review 3.  The effects of tourniquet use on blood loss in primary total knee arthroplasty for patients with osteoarthritis: a meta-analysis.

Authors:  D F Cai; Q H Fan; H H Zhong; S Peng; H Song
Journal:  J Orthop Surg Res       Date:  2019-11-08       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.