Literature DB >> 25709916

Comparison of retinal nerve fiber layer and macular thickness measurements with Stratus OCT and OPKO/OTI OCT devices in healthy subjects.

Ahmet Ozkok1, Julide Canan Umurhan Akkan2, Nevbahar Tamcelik1, Mehmet Erdogan1, Didar Ucar Comlekoglu1, Rengin Yildirim1.   

Abstract

AIM: To compare retinal nerve fiber layer (RNFL) and macular thickness measurements obtained with the Stratus optical coherence tomography (OCT) and OPKO/OTI OCT devices.
METHODS: Included in the study were 59 eyes of 30 participants. All measurements for each eye were done on the same day with both devices. Student's paired t-tests were used to compare the central macular thickness and RNFL measurements of the Stratus OCT and OPKO/OTI OCT. Pearson correlation was used to assess the relationship between the devices. Coefficient of variation (COV) was calculated to assess intersession repeatability.
RESULTS: Using both the Stratus OCT and OPKO/OTI OCT, respectively, the measured mean average RNFL thicknesses were 98.9±11.1 µm and 115.1±9.6 µm (P=0.001), and the measured mean central retinal thicknesses (CRT) were 196.2±18.8 µm and 204.5±21.1 µm (P<0.001). Measured by the two devices, the RNFL thickness values were correlated in all quadrants, as were the retinal thickness values except the inferior outer sector. COV for average RNFL and CRT thickness were 2.9% and 4.6% for Stratus OCT, and 2.1% and 4.2% for OPKO/OTI OCT, respectively.
CONCLUSION: We found good reproducibility of RNFL and retina thickness measurements for both Stratus OCT and OPKO/OTI OCT devices. However, even though the two OCT systems provided statistically correlated results, the values for both RNFL and macular thickness were statistically different. RNFL and macular thickness measurements with the OPKO/OTI OCT were higher than that of the Stratus OCT; therefore, the two OCT systems cannot be used interchangeably for the measurements of RNFL and macular thickness.

Entities:  

Keywords:  OPKO/OTI OCT; Stratus optical coherence tomography; macular thickness; optical coherence tomography; retinal nerve fiber layer

Year:  2015        PMID: 25709916      PMCID: PMC4325250          DOI: 10.3980/j.issn.2222-3959.2015.01.18

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  22 in total

1.  Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3).

Authors:  Rabia Gürses-Ozden; Christopher Teng; Roberto Vessani; Samiah Zafar; Jeffrey M Liebmann; Robert Ritch
Journal:  J Glaucoma       Date:  2004-06       Impact factor: 2.503

2.  Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT.

Authors:  Lelia A Paunescu; Joel S Schuman; Lori Lyn Price; Paul C Stark; Siobahn Beaton; Hiroshi Ishikawa; Gadi Wollstein; James G Fujimoto
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-06       Impact factor: 4.799

3.  Comparison of retinal nerve fiber layer thickness in normal eyes using time-domain and spectral-domain optical coherence tomography.

Authors:  Leonard K Seibold; Naresh Mandava; Malik Y Kahook
Journal:  Am J Ophthalmol       Date:  2010-12       Impact factor: 5.258

4.  Reproducibility of retinal nerve fiber thickness measurements using the test-retest function of spectral OCT/SLO in normal and glaucomatous eyes.

Authors:  Sun Ho Lee; Seok Hwan Kim; Tae-Woo Kim; Ki Ho Park; Dong Myung Kim
Journal:  J Glaucoma       Date:  2010-12       Impact factor: 2.503

5.  Retinal nerve fiber layer thickness reproducibility using seven different OCT instruments.

Authors:  Luisa Pierro; Marco Gagliardi; Lorenzo Iuliano; Alessandro Ambrosi; Francesco Bandello
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-08-31       Impact factor: 4.799

6.  Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes.

Authors:  Donald L Budenz; Robert T Chang; Xiangrun Huang; Robert W Knighton; James M Tielsch
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-07       Impact factor: 4.799

7.  Macular thickness measurements in healthy eyes using six different optical coherence tomography instruments.

Authors:  Ute E K Wolf-Schnurrbusch; Lala Ceklic; Christian K Brinkmann; Milko E Iliev; Manuel Frey; Simon P Rothenbuehler; Volker Enzmann; Sebastian Wolf
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-02-21       Impact factor: 4.799

8.  Comparison of retinal thickness in normal eyes using Stratus and Spectralis optical coherence tomography.

Authors:  Sandeep Grover; Ravi K Murthy; Vikram S Brar; Kakarla V Chalam
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-12-10       Impact factor: 4.799

9.  Macular thickness measurements in normal eyes with time-domain and Fourier-domain optical coherence tomography.

Authors:  Jingjing Huang; Xing Liu; Ziqiang Wu; Hui Xiao; Laurie Dustin; Srinivas Sadda
Journal:  Retina       Date:  2009 Jul-Aug       Impact factor: 4.256

10.  Comparison of retinal nerve fiber layer thickness measurements in healthy subjects using fourier and time domain optical coherence tomography.

Authors:  Isabel Pinilla; Elena Garcia-Martin; Miriam Idoipe; Eva Sancho; Isabel Fuertes
Journal:  J Ophthalmol       Date:  2012-05-29       Impact factor: 1.909

View more
  2 in total

1.  Normative Values of Peripapillary Retinal Nerve Fiber Layer Thickness in a Middle Eastern Population.

Authors:  Mouna M Al-Sa'ad; Amjad T Shatarat; Justin Z Amarin; Darwish H Badran
Journal:  J Ophthalmol       Date:  2018-09-17       Impact factor: 1.909

2.  Comparing Macular Thickness Measurements in Patients with Diabetic Macular Edema with the Optos Spectral OCT/SLO and Heidelberg Spectralis HRA + OCT.

Authors:  Amun Sachdev; Magdalena Edington; Rupal Morjaria; Ngaihang Victor Chong
Journal:  Vision (Basel)       Date:  2016-04-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.