Literature DB >> 25706135

Development and validation of a GEANT4 radiation transport code for CT dosimetry.

D E Carver1, S D Kost, M J Fernald, K G Lewis, N D Fraser, D R Pickens, R R Price, M G Stabin.   

Abstract

The authors have created a radiation transport code using the GEANT4 Monte Carlo toolkit to simulate pediatric patients undergoing CT examinations. The focus of this paper is to validate their simulation with real-world physical dosimetry measurements using two independent techniques. Exposure measurements were made with a standard 100-mm CT pencil ionization chamber, and absorbed doses were also measured using optically stimulated luminescent (OSL) dosimeters. Measurements were made in air with a standard 16-cm acrylic head phantom and with a standard 32-cm acrylic body phantom. Physical dose measurements determined from the ionization chamber in air for 100 and 120 kVp beam energies were used to derive photon-fluence calibration factors. Both ion chamber and OSL measurement results provide useful comparisons in the validation of the Monte Carlo simulations. It was found that simulated and measured CTDI values were within an overall average of 6% of each other.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25706135      PMCID: PMC4339227          DOI: 10.1097/HP.0000000000000243

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  24 in total

1.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

2.  NCRP Report No. 160, Ionizing Radiation Exposure of the Population of the United States, medical exposure--are we doing less with more, and is there a role for health physicists?

Authors:  D A Schauer; O W Linton
Journal:  Health Phys       Date:  2009-07       Impact factor: 1.316

3.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations.

Authors:  Adam C Turner; Di Zhang; Hyun J Kim; John J DeMarco; Chris H Cagnon; Erin Angel; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

4.  Characterization of a commercially-available, optically-stimulated luminescent dosimetry system for use in computed tomography.

Authors:  Lindsey Lavoie; Monica Ghita; Libby Brateman; Manuel Arreola
Journal:  Health Phys       Date:  2011-09       Impact factor: 1.316

5.  Patient-specific radiation dose and cancer risk estimation in CT: part I. development and validation of a Monte Carlo program.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Greta Toncheva; Terry T Yoshizumi; Donald P Frush
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

6.  Patient-specific radiation dose and cancer risk estimation in CT: part II. Application to patients.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Greta Toncheva; Terry T Yoshizumi; Donald P Frush
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

7.  Patient-specific radiation dose and cancer risk for pediatric chest CT.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Donald P Frush
Journal:  Radiology       Date:  2011-04-05       Impact factor: 11.105

8.  Image Gently Vendor Summit: working together for better estimates of pediatric radiation dose from CT.

Authors:  Keith J Strauss; Marilyn J Goske; Donald P Frush; Priscilla F Butler; Gregory Morrison
Journal:  AJR Am J Roentgenol       Date:  2009-05       Impact factor: 3.959

9.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2007

10.  Hybrid computational phantoms of the 15-year male and female adolescent: applications to CT organ dosimetry for patients of variable morphometry.

Authors:  Choonsik Lee; Daniel Lodwick; Jonathan L Williams; Wesley E Bolch
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

View more
  3 in total

1.  Recent Publications by Ochsner Authors.

Authors: 
Journal:  Ochsner J       Date:  2015

2.  Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis.

Authors:  Susan D Kost; Nicholas D Fraser; Diana E Carver; David R Pickens; Ronald R Price; Marta Hernanz-Schulman; Michael G Stabin
Journal:  Pediatr Radiol       Date:  2015-07-04

3.  Realistic phantoms to characterize dosimetry in pediatric CT.

Authors:  Diana E Carver; Susan D Kost; Nicholas D Fraser; W Paul Segars; David R Pickens; Ronald R Price; Michael G Stabin
Journal:  Pediatr Radiol       Date:  2017-03-10
  3 in total