Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments.

Natasha C C Ajuz1, Luciana Armada, Lucio S Gonçalves, Gilberto Debelian, José F Siqueira.   

Abstract

INTRODUCTION: This study compared the incidence of deviation along S-shaped (double-curved) canals after glide path preparation with 2 nickel-titanium (NiTi) rotary pathfinding instruments and hand K-files.
METHODS: S-shaped canals from 60 training blocks were filled with ink, and preinstrumentation images were obtained by using a stereomicroscope. Glide path preparation was performed by an endodontist who used hand stainless steel K-files (up to size 20), rotary NiTi PathFile instruments (up to size 19), or rotary NiTi Scout RaCe instruments (up to size 20). Postinstrumentation images were taken by using exactly the same conditions as for the preinstrumentation images, and both pictures were superimposed. Differences along the S-shaped canal for the mesial and distal aspects were measured to evaluate the occurrence of deviation.
RESULTS: Intragroup analysis showed that all instruments promoted some deviation in virtually all levels. Overall, regardless of the group, deviations were observed in the mesial wall at the canal terminus and at levels 4, 5, 6 and 7 mm and in the distal wall at levels 1, 2, and 3 mm. These levels corresponded to the inner walls of each curvature. Both rotary NiTi instruments performed significantly better than hand K-files at all levels (P < .05), except for PathFiles at the 0-mm level. ScoutRaCe instruments showed significantly better results than PathFiles at levels 0, 2, 3, 5, and 6 mm (P < .05).
CONCLUSIONS: Findings suggest that rotary NiTi instruments are suitable for adequate glide path preparation because they promoted less deviation from the original canal anatomy when compared with hand-operated instruments. Of the 2 rotary pathfinding instruments, Scout RaCe showed an overall significantly better performance.
Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23522552     DOI: 10.1016/j.joen.2012.12.025

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  12 in total

1.  Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation.

Authors:  Ana Arias; Rupinderpal Singh; Ove A Peters
Journal:  Odontology       Date:  2015-02-21       Impact factor: 2.634

2.  Evaluation of the Canal Transportation Following Glide Path Preparation with Different Rotary Systems: A Comparative Study.

Authors:  Mohsen Aminsobhani; Fatemeh Hamidzadeh; Arvin Rezaei Avval; Farid Merrikhi; Ehsan Sadri
Journal:  ScientificWorldJournal       Date:  2022-06-30

3.  Comparative Assessment of the Shaping Ability of Reciproc Blue, WaveOne Gold, and ProTaper Gold in Simulated Root Canals.

Authors:  Laura Orel; Oana-Alexandra Velea-Barta; Cosmin Sinescu; Virgil-Florin Duma; Luminița-Maria Nica; Razvan Mihai Horhat; Raul Dorin Chirila; Anca Tudor; Dan-Dumitru Vulcănescu; Meda Lavinia Negrutiu
Journal:  Materials (Basel)       Date:  2022-04-21       Impact factor: 3.748

4.  Comparison of canal transportation in simulated curved canals prepared with ProTaper Universal and ProTaper Gold systems.

Authors:  Emmanuel João Nogueira Leal Silva; Brenda Leite Muniz; Frederico Pires; Felipe Gonçalves Belladonna; Aline Almeida Neves; Erick Miranda Souza; Gustavo De-Deus
Journal:  Restor Dent Endod       Date:  2016-02-04

5.  Increase in [corrected] the glyde path diameter improves the centering ability of F6 Skytaper.

Authors:  Giuseppe Troiano; Mario Dioguardi; Armando Cocco; Khrystyna Zhurakivska; Domenico Ciavarella; Lorenzo Lo Muzio
Journal:  Eur J Dent       Date:  2018 Jan-Mar

6.  Glide path enlargement of curved molar canals using HyFlex EDM glide path file versus PathFile: a comparative study of preparation time and postoperative pain.

Authors:  Yi Han; Xiao-Mei Hou
Journal:  BMC Oral Health       Date:  2021-03-23       Impact factor: 2.757

7.  In Vitro Transportation of Curved Canals Following Glide Path Preparation by Path File and Scout RaCe Rotary Systems versus Manual Instrumentation Using Cone-Beam Computed Tomography.

Authors:  Sareh Aflaki; Elham Boyerahmadi; Amir Talaei; Mohammad Raouf Safari; Mahdis Mohammadpour; Navid Mohammadi; Mamak Adel
Journal:  Front Dent       Date:  2020-11-15

Review 8.  The Effect of Glide Path Preparation on Root Canal Shaping Procedures and Outcomes.

Authors:  Mahdi Ajina; Georgios Billis; Bun San Chong
Journal:  Eur Endod J       Date:  2022-06

9.  Transportation Assessment in Simulated Curved Canals after preparation with Twisted File Adaptive and BT-Race instruments.

Authors:  Carlos-Vieira Andrade-Junior; Nilton-Dessaune Neto; Renata-Costa-Val Rodrigues; Henrique-Dos Santos Antunes; Mariana-Teixeira-Maneschy Porpino; Júlio-Cesar A Carvalhal; Luciana Armada
Journal:  J Clin Exp Dent       Date:  2017-09-01

10.  Preservation of root canal anatomy using self-adjusting file instrumentation with glide path prepared by 20/0.02 hand files versus 20/0.04 rotary files.

Authors:  Niharika Jain; Ajinkya M Pawar; Piyush D Ukey; Prashant K Jain; Bhagyashree Thakur; Abhishek Gupta
Journal:  J Conserv Dent       Date:  2017 Mar-Apr
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.