Anatomic study of individualized and improved pedicle screw implantation in the lower cervical spine.

Yuan Liu1, Bin Zhang, Min Dai, Han-chu Xiong, Song Gao, Bin-hua Li, Hao-qun Yao, Kai Cao, Zhi-li Liu.   

Abstract

The objective of this study was to explore a safe, reliable, and effective method for pedicle screw implantation in the lower cervical spine. Recently, a number of studies have shown that cervical pedicle screw fixation is better than roadside steel plate after cervical screw internal fixation within the scope of its indications. However, the difficulty of the former surgery technology is relatively higher and it is much easier to cause many complications. Therefore, domestic and foreign scholars have been positively exploring safer, easier operations and cheaper methods of pedicle screw implantation in the lower cervical spine. The lower cervical spine areas (C3-C7) of 7 adult cadavers were carried out with computed tomography (CT) scans of 1-mm slices. The entry point, angle, and length of the screws were determined by the measurement of CT images in a picture archiving and communication system. The pedicle screws were implanted with the technique of improved Abumi pedicle screw placement in the lab. The accuracy of the screws was evaluated by the Andrew CT classification criteria of pedicle screw position and gross observation after the experiment. A total of 66 screws were implanted in the lower cervical spine, and 90.9% of the screws inserted were found to be in an optimal position. The method of individualized and improved pedicle screw implantation in the lower cervical spine is relatively safe and reliable, which can be considered to be used in the clinic.

Entities:  

Keywords:  Anatomy; Improvement; Individualization; Lower cervical spine; Pedicle screw

Mesh:

Year:  2015        PMID: 25692438      PMCID: PMC4337450          DOI: 10.9738/INTSURG-D-14-00216.1

Source DB:  PubMed          Journal:  Int Surg        ISSN: 0020-8868


  21 in total

Review 1.  Transpedicle screw fixation of the cervical spine.

Authors:  S C Ludwig; D L Kramer; A R Vaccaro; T J Albert
Journal:  Clin Orthop Relat Res       Date:  1999-02       Impact factor: 4.176

2.  Accuracy of cervical pedicle screw placement using the funnel technique.

Authors:  E E Karaikovic; W Yingsakmongkol; R W Gaines
Journal:  Spine (Phila Pa 1976)       Date:  2001-11-15       Impact factor: 3.468

3.  Improved accuracy of computer-assisted cervical pedicle screw insertion.

Authors:  Yoshihisa Kotani; Kuniyoshi Abumi; Manabu Ito; Akio Minami
Journal:  J Neurosurg       Date:  2003-10       Impact factor: 5.115

4.  Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization.

Authors:  E E Karaikovic; S Kunakornsawat; M D Daubs; T W Madsen; R W Gaines
Journal:  J Spinal Disord       Date:  2000-02

5.  Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle.

Authors:  Takeshi Sakamoto; Masashi Neo; Takashi Nakamura
Journal:  Spine (Phila Pa 1976)       Date:  2004-11-15       Impact factor: 3.468

6.  Morphometry of the cervical vertebral pedicles as a guide for transpedicular screw fixation.

Authors:  Gulgun Kayalioglu; Mete Erturk; Tuncay Varol; Enis Cezayirli
Journal:  Neurol Med Chir (Tokyo)       Date:  2007-03       Impact factor: 1.742

7.  Morphologic characteristics of human cervical pedicles.

Authors:  E E Karaikovic; M D Daubs; R W Madsen; R W Gaines
Journal:  Spine (Phila Pa 1976)       Date:  1997-03-01       Impact factor: 3.468

8.  Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine.

Authors:  Y Kotani; B W Cunningham; K Abumi; P C McAfee
Journal:  Spine (Phila Pa 1976)       Date:  1994-11-15       Impact factor: 3.468

9.  Pedicle screw fixation for nontraumatic lesions of the cervical spine.

Authors:  K Abumi; K Kaneda
Journal:  Spine (Phila Pa 1976)       Date:  1997-08-15       Impact factor: 3.468

10.  Morphometric evaluation of subaxial cervical spine using multi-detector computerized tomography (MD-CT) scan: the consideration for cervical pedicle screws fixation.

Authors:  Pongsthorn Chanplakorn; Chaiwat Kraiwattanapong; Kitti Aroonjarattham; Pittavat Leelapattana; Gun Keorochana; Suphaneewan Jaovisidha; Wiwat Wajanavisit
Journal:  BMC Musculoskelet Disord       Date:  2014-04-11       Impact factor: 2.362

View more
  3 in total

1.  Accuracy of a dynamic surgical guidance probe for screw insertion in the cervical spine: a cadaveric study.

Authors:  Daniel Dixon; Bruce Darden; Jose Casamitjana; Karen A Weissmann; San Cristobal; David Powell; Daniel Baluch
Journal:  Eur Spine J       Date:  2016-11-14       Impact factor: 3.134

2.  Evaluation of Multi-Slice Spiral Computed Tomography in In vivo Simulation of Individualized Cervical Pedicle Screw Placement at C3-C7 in Chinese Healthy Population.

Authors:  Wei Chen; Xiang-Ming Fang; Ping-Yan Qian; P S Sanjeev Kumar; Hong-Wei Chen; H U Xiao-Yun
Journal:  Indian J Orthop       Date:  2018 Nov-Dec       Impact factor: 1.251

3.  Medial Pedicle Pivot Point Using Preoperative Computed Tomography Morphometric Measurements for Cervical Pedicle Screw Insertion: A Novel Technique and Case Series.

Authors:  Ji-Won Kwon; Edward O Arreza; Anthony A Suguitan; Soo-Bin Lee; Sahyun Sung; Yung Park; Joong-Won Ha; Tae Hyung Kim; Seong-Hwan Moon; Byung Ho Lee
Journal:  J Clin Med       Date:  2022-01-13       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.