Literature DB >> 25687978

Open-irrigated laser catheter ablation: influence of catheter-tissue contact force on lesion formation.

Michaela Sagerer-Gerhardt1, Helmut P Weber.   

Abstract

PURPOSE: Catheter-tissue contact force (CF) is a major determinant for radiofrequency (RF) ablation lesion size and quality. We sought to test the influence of catheter CF on lesion formation by using an open-irrigated electrode-laser mapping and ablation (ELMA) catheter.
METHODS: With the ELMA catheter in a stable vertical position, continuous wave 1064 nm laser impacts at 15 W (9.5 W/mm(2)), 30 s (285 J/mm(2)), irrigation flow 30 mL/min, were aimed at the endocardial surface of bovine myocardium in heparinized stagnant blood (ACT >350 s) at room temperature (18 °C). Lesions were produced with CFs of 100 g, 10 g, in contact but without pressure, with the catheter tip 2.0 mm, and 5.0 mm away (n = 10, each). Lesions were evaluated morphometrically and were compared by the unpaired t tests.
RESULTS: There were no significant differences between volumes of lesions achieved with catheter-tissue CF of 100 g, 10 g, and in contact without pressure: 297 ± 56.0 vs. 300 ± 39 vs. 320 ± 24, respectively (p > 0.05). However, volumes of lesions produced at a distance of 2 mm (95 ± 14 mm(3)) were significantly smaller (p < 0.0001), whereas at a distance of 5.0 mm, no lesions were produced. No steam-pop with crater or thrombus formation occurred.
CONCLUSIONS: By using an open-irrigated ELMA catheter, catheter-tissue CF is not a determinant for laser ablation lesion size and quality. Maximum sizes of lesions can be achieved with the catheter in intimate endocardial contact without pressure. However, lesions can be produced also at a catheter-tissue distance of 2.0 mm. Noticeably, there is no thrombus formation during laser application with the free floating ELMA catheter in the stagnant blood.

Entities:  

Mesh:

Year:  2015        PMID: 25687978     DOI: 10.1007/s10840-015-9977-4

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  28 in total

1.  Bio-battery signal predicts myocardial lesion formation and depth in vitro.

Authors:  D S He; P Sharma; X Wang; M Bosnos; F I Marcus
Journal:  J Interv Card Electrophysiol       Date:  1999-03       Impact factor: 1.900

2.  Current practice of ventricular tachycardia ablation in patients with implantable cardioverter-defibrillators.

Authors:  Nikolaos Dagres; Francesco Cantù; Peter Geelen; Thorsten Lewalter; Alessandro Proclemer; Carina Blomström-Lundqvist
Journal:  Europace       Date:  2012-01       Impact factor: 5.214

3.  Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model.

Authors:  Dipen C Shah; Hendrik Lambert; Hiroshi Nakagawa; Arne Langenkamp; Nicolas Aeby; Giovanni Leo
Journal:  J Cardiovasc Electrophysiol       Date:  2010-09

Review 4.  Principles of lasers and biophotonic effects.

Authors:  Verena Knappe; Frank Frank; Ewa Rohde
Journal:  Photomed Laser Surg       Date:  2004-10       Impact factor: 2.796

5.  Monitoring of laser effects on the conduction system by using an open-irrigated electrode-laser mapping and ablation catheter: laser catheter mapping.

Authors:  Helmut P Weber; Michaela Sagerer-Gerhardt
Journal:  Europace       Date:  2015-01-09       Impact factor: 5.214

6.  Radiofrequency and cryoenergy endo-epicardical catheter and surgical approach for a case of incessant ventricular tachycardia ablation.

Authors:  Pasquale Vergara; Francesco Maisano; Giuseppe Maccabelli; Paolo Della Bella
Journal:  Europace       Date:  2013-01-30       Impact factor: 5.214

7.  Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study.

Authors:  Petr Neuzil; Vivek Y Reddy; Josef Kautzner; Jan Petru; Dan Wichterle; Dipen Shah; Hendrik Lambert; Aude Yulzari; Erik Wissner; Karl-Heinz Kuck
Journal:  Circ Arrhythm Electrophysiol       Date:  2013-03-20

8.  Open-irrigated laser catheter ablation produces flow-dependent sizes of lesions.

Authors:  Helmut P Weber; Michaela Sagerer-Gerhardt
Journal:  Pacing Clin Electrophysiol       Date:  2013-05-10       Impact factor: 1.976

9.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study.

Authors:  Vivek Y Reddy; Dipen Shah; Josef Kautzner; Boris Schmidt; Nadir Saoudi; Claudia Herrera; Pierre Jaïs; Gerhard Hindricks; Petr Peichl; Aude Yulzari; Hendrik Lambert; Petr Neuzil; Andrea Natale; Karl-Heinz Kuck
Journal:  Heart Rhythm       Date:  2012-07-20       Impact factor: 6.343

10.  Endocardial and epicardial radiofrequency ablation of ventricular tachycardia associated with dilated cardiomyopathy: the importance of low-voltage scars.

Authors:  Kyoko Soejima; William G Stevenson; John L Sapp; Andrew P Selwyn; Gregory Couper; Laurence M Epstein
Journal:  J Am Coll Cardiol       Date:  2004-05-19       Impact factor: 24.094

View more
  2 in total

1.  Influence of catheter orientation on lesion formation in bovine myocardium by using an open-irrigated laser ablation catheter.

Authors:  Michaela Sagerer-Gerhardt; Helmut P Weber
Journal:  Lasers Med Sci       Date:  2016-06-10       Impact factor: 3.161

2.  Laser catheter ablation of long- lasting persistent atrial fibrillation: Longterm results.

Authors:  Helmut Weber; Michaela Sagerer-Gerhardt; Armin Heinze
Journal:  J Atr Fibrillation       Date:  2017-08-31
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.